192 research outputs found

    Can We Make Money with Fifth-order Autocorrelation in Japanese Stock Prices?

    Get PDF
    We first report that one-minute returns on TOPIX have exhibited significant autocorrelation at five-minute intervals since 1997/98, which implies there is an arbitrage opportunity. Special quotes that are issued whenever there is a price jump in excess of a predetermined band seem to be the source of this autocorrelation, since these have been updated at five-minute intervals since August 1998. Individual stock returns also exhibit fifth-order autocorrelation, but this disappears when the data with special quotes are excluded from the sample. The arbitrage opportunities, however, turn out to be spurious since trading is suspended whenever a special quote is issued.

    Can We Make Money with Fifth-order Autocorrelation in Japanese Stock Prices?

    Full text link

    Humidification of Base Flow Gas during Adult High-Frequency Oscillatory Ventilation:An Experimental Study Using a Lung Model

    Get PDF
    In adult high-frequency oscillatory ventilation (HFOV) with an R100 artificial ventilator, exhaled gas from patientʼs lung may warm the temperature probe and thereby disturb the humidification of base flow (BF) gas. We measured the humidity of BF gas during HFOV with frequencies of 6, 8 and 10Hz, maximum stroke volumes (SV) of 285, 205, and 160ml at the respective frequencies, and, BFs of 20, 30, 40l/min using an original lung model. The R100 device was equipped with a heated humidifier, HummaxⅡ, consisting of a porous hollow fiber in circuit. A 50-cm length of circuit was added between temperature probe (located at 50cm proximal from Y-piece) and the hollow fiber. The lung model was made of a plastic container and a circuit equipped with another HummaxⅡ. The lung model temperature was controlled at 37℃. The HummaxⅡ of the R100 was inactivated in study-1 and was set at 35℃ or 37℃ in study-2. The humidity was measured at the distal end of the added circuit in study-1 and at the proximal end in study-2. In study-1, humidity was detected at 6Hz (SV 285ml) and BF 20l/min, indicating the direct reach of the exhaled gas from the lung model to the temperature probe. In study-2 the absolute humidity of the BF gas decreased by increasing SV and by increasing BF and it was low with setting of 35℃. In this study setting, increasing the SV induced significant reduction of humidification of the BF gas during HFOV with R100

    Mean Lung Pressure during Adult High-Frequency Oscillatory Ventilation: An Experimental Study Using a Lung Model

    Get PDF
    In adult high-frequency oscillatory ventilation (HFOV), stroke volume (SV) and mean lung pressure (PLung) are important for lung protection. We measured the airway pressure at the Y-piece and the lung pressure during HFOV using a lung model and HFOV ventilators for adults (R100 and 3100B). The lung model was made of a 20-liter, airtight rigid plastic container (adiabatic compliance: 19.3ml/cmH2O) with or without a resistor (20cmH2O/l/sec). The ventilator settings were as follows: mean airway pressure (MAP), 30cmH2O;frequency, 5-15Hz (every 1Hz);airway pressure amplitude (AMP), maximum;and % of inspiratory time (IT), 50% for R100, 33% or 50% for 3100B. The measurements were also performed with an AMP of 2/3 or 1/3 maximum at 5, 10 and 15Hz. The PLung and the measured MAP were not consistently identical to the setting MAP in either ventilator, and decreasing IT decreased the PLung in 3100B. In conclusion, we must pay attention to the possible discrepancy between the PLung and the setting MAP during adult HFOV

    Portal Venous Gas Following Ingestion of Hydrogen Peroxide Successfully Treated with Hyperbaric Oxygen Therapy

    Get PDF
    The primary toxicity of hydrogen peroxide results from its interaction with catalase, which liberates water and oxygen. We report the case of a 14-year-old Japanese girl with portal venous gas that was caused by oxygen liberated from intentionally ingested hydrogen peroxide. Although she had a past history of atrial septal defect, recovery without cardiac or neurological sequelae was achieved using hyperbaric oxygen therapy. Emergency physicians must be aware of the danger of liberated oxygen due to hydrogen peroxide ingestion
    corecore