A noise study of the A-6 airplane and techniques for reducing its aural detection distance
A study was undertaken to determine the noise reduction potential of the A-6 airplane in order to reduce its aural detection distance. Static and flyby noise measurements were taken to document the basic airplane signature. The low-frequency noise which is generally most critical for aural detection was found to be broad-band in nature from this airplane, and its source is the turbojet engine exhaust. High-frequency compressor noise, which is characteristic of turbojet powerplants, and which is prominent at close range for this airplane, has no measurable effect on aural detection distance. The use of fluted-engine exhaust nozzles to change the far-field noise spectra is suggested as a possible means for reducing the aural detection distances. Detection distances associated with eight-lobe and four-lobe nozzles are estimated for a 1,000-foot altitude and grassy terrain to decrease from 4 miles to about 3 miles, and from 3 miles to about 2 miles for a 300-foot altitude and grassy terrain
Noise reduction studies for the Cessna model 337 (0-2) airplane
A study was undertaken to determine the noise reduction potential of the 0-2 airplane in order to reduce its aural detection distance. Static and flyover noise measurements were made to document the noise signature of the unmodified airplane. The results show that significant reductions in aural detection distance can be achieved by the combination of propeller geometry changes and the addition of engine exhaust mufflers. The best results were estimated for the aircraft equipped with a six-blade propeller operating at 3/4 engine speed in combination with a 3.49 cubic foot exhaust muffler installed on each engine. Detection distance for the modified aircraft is estimated to be reduced from about 4-1/4 miles to about 1-1/2 miles when the aircraft is operating at an altitude of 1,000 ft over grassy terrain. Reducing the altitude to 300 ft over a leafy jungle ground cover should reduce the aural detection distance to 0.9 miles. Reduced aural detection distances were also indicated for a modification utilizing a direct-drive six-blade propeller of reduced radius along with smaller exhaust mufflers
Noise reduction studies for the OV-1 airplane
A study has been conducted to define possible modifications to the OV-1 aircraft to reduce its aural detection distance. This effort involved documenting the noise characteristics of the airplane, devising modifications to reduce the noise, estimating the reduction in detection distance, and evaluating aircraft performance as a result of these modifications. It was found that the main noise source on this aircraft is the propeller and hence modifications only to the propeller and the propeller drive system are proposed. Modifications involving only the propeller are noted to involve no increase in weight but they result in only a modest decrease in aural detection distance. In order to obtain substantial decreases in aural detection distance, modifications involving changes both to the propeller and the engine-propeller gearing are required
Noise characteristics of the O-1 airplane and some approaches to noise reduction
A brief study of the O-1A airplane to determine possible means for reducing the aircraft aural detection distance was conducted. This effort involved measuring the noise signature of the basic airplane, devising methods to attenuate the noise, and then estimating the effect of several selected modifications on the aural detection distance of the aircraft. A relatively simple modification utilizing a 6.5 ft diameter, six-blade propeller and including a muffler having a volume of 0.725 cu ft is indicated to reduce the aural detection distance of the O-1 aircraft from about 6 miles at an altitude of 1,000 ft and 2 to 3 miles at an altitude of 300 ft to approximately half these values. The flyover noise data suggest that routing the exhaust stacks up and over the wing would provide immediate noise reduction of about 5 dB with an attendant reduction in detection distance. Furthermore, all these studies confirm the work of other investigators that the 1/3 octave band (center frequency=125 cps) is the most critical in reducing aural detection distance
Noise reduction studies for the U-10 airplane
A study was undertaken by the NASA Langley Research Center to determine the noise reduction potential of the U-10 airplane in order to reduce its aural detection distance. Static and flyover noise measurements were made to document the basic airplane noise signature. Two modifications to the airplane configuration are suggested as having the best potential for substantially reducing aural detection distance with small penalty to airplane performance or stability and control. These modifications include changing the present 3-blade propeller to a 5-blade propeller, changing the propeller diameter, and changing the propeller gear ratio, along with the use of an engine exhaust muffler. The aural detection distance corresponding to normal cruising flight at an altitude of 1,000 ft over grassy terrain is reduced from 28,000 ft (5.3 miles) to about 50 percent of that value for modification 1, and to about 25 percent for modification 2. For the aircraft operating at an altitude of 300 ft, the analysis indicates that relatively straightforward modifications could reduce the aural detection distance to approximately 0.9 mile. Operation of the aircraft at greatly reduced engine speed (1650 rpm) with a 1.3-cu-ft muffler provides aural detection distances slightly lower than modification 1
The nuclear scissors mode within two approaches (Wigner function moments versus RPA)
Two complementary methods to describe the collective motion, RPA and Wigner
function moments method, are compared on an example of a simple model -
harmonic oscillator with quadrupole-quadrupole residual interaction. It is
shown that they give identical formulae for eigenfrequencies and transition
probabilities of all collective excitations of the model including the scissors
mode, which here is the subject of our special attention. The exact relation
between the variables of the two methods and the respective dynamical equations
is established. The normalization factor of the "synthetic" scissors state and
its overlap with physical states are calculated analytically. The orthogonality
of the spurious state to all physical states is proved rigorously.Comment: 39 page
The effect of operations on the ground noise footprints associated with a large multibladed, nonbanging helicopter
In order to expand the data base of helicopter external noise characteristics, a flyover noise measurement program was conducted utilizing the NASA Civil Helicopter Research Aircraft. The remotely operated multiple array acoustics range (ROMAAR) and a 2560-m linear microphone array were utilized for the purpose of documenting the noise characteristics of the test helicopter during flyby and landing operations. By utilizing both ROMAAR concept and the linear array, the data necessary to plot the ground noise footprints and noise radiation patterns were obtained. Examples of the measured noise signature of the test helicopter, the ground noise footprint or contours, and the directivity patterns measured during level flyby and landing operations of a large, multibladed, nonbanging helicopter, the CH-53, are presented
Time-division SQUID multiplexers with reduced sensitivity to external magnetic fields
Time-division SQUID multiplexers are used in many applications that require
exquisite control of systematic error. One potential source of systematic error
is the pickup of external magnetic fields in the multiplexer. We present
measurements of the field sensitivity figure of merit, effective area, for both
the first stage and second stage SQUID amplifiers in three NIST SQUID
multiplexer designs. These designs include a new variety with improved
gradiometry that significantly reduces the effective area of both the first and
second stage SQUID amplifiers.Comment: 4 pages, 7 figures. Submitted for publication in the IEEE
Transactions on Applied Superconductivity, August 201
The hydrological regime of a forested tropical Andean catchment.
The hydrology of tropical mountain catchments plays a central role in ecological function, geochemical and biogeochemical cycles, erosion and sediment production, and water supply in globally important environments. There have been few studies quantifying the seasonal and annual water budgets in the montane tropics, particularly in cloud forests. We investigated the water balance and hydrologic regime of the Kosñipata catchment (basin area: 164.4 km2) over the period 2010–2011. The catchment spans over 2500 m in elevation in the eastern Peruvian Andes and is dominated by tropical montane cloud forest with some high-elevation puna grasslands. Catchment-wide rainfall was 3112 ± 414 mm yr−1, calculated by calibrating Tropical Rainfall Measuring Mission (TRMM) 3B43 rainfall with rainfall data from nine meteorological stations in the catchment. Cloud water input to streamflow was 316 ± 116 mm yr−1 (9.2% of total inputs), calculated from an isotopic mixing model using deuterium excess (Dxs) and δD of waters. Field streamflow was measured in 2010 by recording height and calibrating to discharge. River run-off was estimated to be 2796 ± 126 mm yr−1. Actual evapotranspiration (AET) was 688 ± 138 mm yr−1, determined using the Priestley and Taylor–Jet Propulsion Laboratory (PT-JPL) model. The overall water budget was balanced within 1.6 ± 13.7%. Relationships between monthly rainfall and river run-off follow an anticlockwise hysteresis through the year, with a persistence of high run-off after the end of the wet season. The size of the soil and shallow groundwater reservoir is most likely insufficient to explain sustained dry-season flow. Thus, the observed hysteresis in rainfall–run-off relationships is best explained by sustained groundwater flow in the dry season, which is consistent with the water isotope results that suggest persistent wet-season sources to streamflow throughout the year. These results demonstrate the importance of transient groundwater storage in stabilising the annual hydrograph in this region of the Andes
- …