11 research outputs found
MRI multiparametric scoring system for pial blood supply of intracranial meningiomas
Background: Meningiomas are occasionally fed by pial blood supply (PBS). It is postulated that peritumoral flow void (PTFV), peritumoral brain edema (PTBE), and absence of an arachnoid plane (AP) are useful parameters for evaluating PBS. Purpose: To determine whether conventional magnetic resonance imaging (MRI) using a multiparametric scoring system (MSS) is a useful way to predict PBS. Material and Methods: Forty-six patients were included and divided: PBS and non-PBS groups. Differences between the groups in six parameters of MR imaging were analyzed: tumor size, tumor location, PTBE grade, AP grade, PTFV, and MIB1 labeling index (MIB1-LI) grade. Cutoff values were determined using receiver operating characteristic (ROC) curve analysis for the differentiation of both groups based on statistically significant parameters. All cases were scored as 1 (PBS) or 0 (non-PBS) for each parameter according to set thresholds. Individual scores were totaled for each case, yielding a combined score for each case to obtain a cutoff value using ROC curve analysis for the MSS. Results: Peritumoral brain edema grade, AP grade, PTFV, and MIB-LI grade were statistically associated with PBS. Receiver operating characteristic curve analyses showed that PTBE grade 3 or 4, AP grade 3 or 4, and PTFV positivity had the highest accuracy of 69%, 64%, and 68%, respectively. Regarding the MSS, a cutoff value of 2 had the highest accuracy of 71%; PBS diagnosis was indicated by at least two of the three parameters, namely, PTBE grade, AP grade, and PTFV. Conclusion: The MSS is a useful way to predict PBS in intracranial meningiomas on MRI
A Rare Case of Idiopathic Spinal Cord Herniation Treated by DuraGen® Collagen Matrix Graft
We report a rare case of idiopathic spinal cord herniation (ISCH) with a history of cerebrospinal fluid (CSF) leakage. ISCH is a protrusion of the spinal cord through a dural defect. Thin constructive interference in steady-state (CISS) images clearly demonstrated the herniated cord in the present case. The myelopathy worsened and the patient underwent surgery for reduction of herniated spinal cord; the dural defect was filled by placing collagen matrix graft (DuraGen®) between the inner and outer dural layers. The patient’s symptoms have improved without relapse for 8 months since surgery. This method may be a good surgical option for cases of spinal cord herniation
A Case of Migration of a Hydrogel Spacer for Radiotherapy into the Pulmonary Artery
A 67-year-old man was referred to our hospital for the diagnosis and treatment of prostate cancer. Multidisciplinary discussion led to intensity-modulated radiotherapy preceded by hormone therapy. Before radiotherapy, a biodegradable hydrogel spacer (HS) was placed between the prostate and rectum to reduce radiation injury risk. Three weeks postplacement, pelvic magnetic resonance imaging revealed HS migration into the pelvic vein. Subsequent whole-body contrast-enhanced computed tomography (CECT) revealed HS migration into the pulmonary artery. The patient showed no symptoms or clinical signs. Radiotherapy was completed uneventfully. Complete absorption of the migrated HS was confirmed using CECT images 5 months postplacement
Evaluation of the ear ossicles with photon-counting detector CT
Recently, computed tomography with photon-counting detector (PCD-CT) has been developed to enable high-resolution imaging at a lower radiation dose. PCD-CT employs a photon-counting detector that can measure the number of incident X-ray photons and their energy. The newly released PCD-CT (NAEOTOM Alpha, Siemens Healthineers, Forchheim, Germany) has been in clinical use at our institution since December 2022. The PCD-CT offers several advantages over current state-of-the-art energy-integrating detector CT (EID-CT). The PCD-CT does not require septa to create a detector channel, while EID-CT does. Therefore, downsizing the anode to achieve higher resolution does not affect the dose efficiency of the PCD-CT. CT is an indispensable modality for evaluating ear ossicles. The ear ossicles and joints are clearly depicted by PCD-CT. In particular, the anterior and posterior legs of the stapes, which are sometimes unclear on conventional CT scans, can be clearly visualized. We present cases of congenital anomalies of the ossicular chain, ossicular chain dislocation, tympanosclerosis, and cholesteatoma in which PCD-CT was useful. This short article reports the usefulness of PCD-CT in the 3D visualization of the ear ossicles
Association between Histological Types and Enhancement of Dynamic CT for Primary Lung Cancer
The aim of this study was to explore enhancement patterns of different types of primary lung cancers on 2-phase dynamic computed tomography (CT). This study included 217 primary lung cancer patients (141 adenocarcinomas [ADs], 48 squamous cell carcinomas [SCCs], 20 small cell lung carcinomas [SCLCs], and 8 others) who were examined using a 2-phase dynamic scan. Regions of interest were identified and mean enhancement values were calculated. After excluding the 20 SCLCs because these lesions had different clinical stages from the other cancer types, the mean attenuation values and subtractions between phases were compared between types of non-small cell lung carcinomas (NSCLCs) using the Kruskal–Wallis test. Late phase attenuation and attenuation of the late minus unenhanced phase (LMU) of SCCs were significantly higher than those of ADs (p<0.05). To differentiate SCC and AD in the late phase, a threshold of 80.21 Hounsfield units (HU) gave 52.9% accuracy. In LMU, a threshold of 52.16 HU gave 59.3% accuracy. Dynamic lung CT has the potential to aid in differentiating among NSCLC types
Photon-Counting Detector CT: Potential for 75% Reduction in Contrast Medium Amount: A Phantom Study
This study aimed to evaluate the potential reduction in contrast medium utilization using photon-counting detector computed tomography (PCD-CT). One PCD-CT scan (CT1) and three conventional (non-PCD-CT) CT scans (CT2-CT4) were performed using a multi-energy CT phantom that contained eight rods with different iodine concentrations (0.2, 0.5, 1, 2, 5, 10, 15, and 20 mg/ml). The CT values of the seven groups (CT1 for 40, 50, 60, and 70 keV; and CT2-4) were measured. Noise and contrast-to-noise ratio (CNR) were assessed for the eight rods at various iodine concentrations. CT2 and CT1 (40 keV) respectively required 20 mg/ml and 5 mg/ml of iodine, indicating that a comparable contrast effect could be obtained with approximately one-fourth of the contrast medium amount. The standard deviation values increased at lower energy levels irrespective of the iodine concentration. The CNR exhibited a decreasing trend with lower iodine concentrations, while it remained relatively stable across all iodine levels (40-70 keV). This study demonstrated that virtual monochromatic 40 keV images offer a similar contrast effect with a reduced contrast medium amount when compared to conventional CT systems at 120 kV
MRI multiparametric scoring system for pial blood supply of intracranial meningiomas
Background: Meningiomas are occasionally fed by pial blood supply (PBS). It is postulated that peritumoral flow void (PTFV), peritumoral brain edema (PTBE), and absence of an arachnoid plane (AP) are useful parameters for evaluating PBS. Purpose: To determine whether conventional magnetic resonance imaging (MRI) using a multiparametric scoring system (MSS) is a useful way to predict PBS. Material and Methods: Forty-six patients were included and divided: PBS and non-PBS groups. Differences between the groups in six parameters of MR imaging were analyzed: tumor size, tumor location, PTBE grade, AP grade, PTFV, and MIB1 labeling index (MIB1-LI) grade. Cutoff values were determined using receiver operating characteristic (ROC) curve analysis for the differentiation of both groups based on statistically significant parameters. All cases were scored as 1 (PBS) or 0 (non-PBS) for each parameter according to set thresholds. Individual scores were totaled for each case, yielding a combined score for each case to obtain a cutoff value using ROC curve analysis for the MSS. Results: Peritumoral brain edema grade, AP grade, PTFV, and MIB-LI grade were statistically associated with PBS. Receiver operating characteristic curve analyses showed that PTBE grade 3 or 4, AP grade 3 or 4, and PTFV positivity had the highest accuracy of 69%, 64%, and 68%, respectively. Regarding the MSS, a cutoff value of 2 had the highest accuracy of 71%; PBS diagnosis was indicated by at least two of the three parameters, namely, PTBE grade, AP grade, and PTFV. Conclusion: The MSS is a useful way to predict PBS in intracranial meningiomas on MRI
Midline invasion predicts poor prognosis in diffuse hemispheric glioma, H3 G34-mutant: an individual participant data review
Introduction Diffuse hemispheric glioma, H3 G34-mutant (DHGs), is a newly categorized tumor in pediatric-type diffuse high-grade gliomas, World Health Organization grade 4, with a poor prognosis. Although prognostic factors associated with genetic abnormalities have been reported, few reports have examined the clinical presentation of DHGs, especially from the viewpoint of imaging findings. In this study, we investigated the relationship between clinical factors, including imaging findings, and prognosis in patients with DHGs.
Methods We searched Medline through the PubMed database using two search terms: “G34” and “glioma”, between 1 April 2012 and 1 July 2023. We retrieved articles that described imaging findings and overall survival (OS), and added one DHG case from our institution. We defined midline invasion (MI) as invasion to the contralateral cerebrum, brainstem, corpus callosum, thalamus, and basal ganglia on magnetic resonance imaging. The primary outcome was 12-month survival, estimated using Kaplan–Meier curves and logistic regression.
Results A total of 96 patients were included in this study. The median age was 22 years, and the proportion of male patients was 48.4%. Lesions were most frequently located in the frontal lobe (52.6%). MI was positive in 39.6% of all patients. The median OS was 14.4 months. Univariate logistic regression analysis revealed that OS was significantly worse in the MI-positive group compared with the MI-negative group. Multivariate logistic regression analysis revealed that MI was an independent prognostic factor in DHGs.
Conclusions In this study, MI-positive cases had a worse prognosis compared with MI-negative cases