6 research outputs found
Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients - Results from the PREPARE (Primary Prevention Parameters Evaluation) study
Objectives Our purpose was to demonstrate that strategically chosen implantable cardioverter-defibrillator (ICD) ventricular tachycardia (VT) or ventricular fibrillation (VF) detection and therapy parameters can reduce the combined incidence of device-delivered shocks, arrhythmic syncope, and untreated sustained symptomatic VT/VF (morbidity index). Background Strategically chosen ICD VT/VF detection and therapy parameters have been shown in previous studies to reduce the number of shocked episodes. In the PREPARE (Primary Prevention Parameters Evaluation) study, these prior strategies were combined with additional strategies specific to primary prevention patients. Methods The PREPARE study was a prospective, cohort-controlled study that analyzed 700 patients (biventricular [Bi-V] ICD and non-Bi-V ICD) with primary prevention indications for an ICD from 38 centers followed for 1 year. VT/VF was detected for rates >= 182 beats/min that were maintained for at least 30 of 40 beats. Antitachycardia pacing was programmed as the first therapy for regular rhythms with rates of 182 to 250 beats/min, and supraventricular tachycardia discriminators were used for rhythms Results The PREPARE programming significantly reduced the morbidity index incidence density (0.26 events/patient-year for PREPARE study patients vs. 0.69 control cohort, p = 0.003). The PREPARE study patients were less likely to receive a shock in the first year compared with control patients (9% vs. 17%, p <0.01). The incidence of untreated VT and arrhythmic syncope was similar between the PREPARE study patients and the control cohort. Conclusions Strategically chosen VT/VF detection and therapy parameters can safely reduce shocks and other morbidities associated with ICD therapy in patients receiving an ICD for primary prevention indications. (PREPARE-Primary Prevention Parameters Evaluation; NCT00279279
Effect of intravenous iron use on hospitalizations in patients undergoing hemodialysis: a comparative effectiveness analysis from the DEcIDE-ESRD study
BackgroundIntravenous iron use in hemodialysis patients has greatly increased over the last decade, despite limited studies on the safety of iron.MethodsWe studied the association of receipt of intravenous iron with hospitalizations in an incident cohort of hemodialysis patients. We examined 9544 patients from Dialysis Clinic, Inc. (DCI). We ascertained intravenous iron use from DCI electronic medical record and USRDS data files, and hospitalizations through Medicare claims. We examined the association between iron exposure accumulated over 1-, 3- or 6-month time windows and incident hospitalizations in the follow-up period using marginal structural models accounting for time-dependent confounders. We performed sensitivity analyses including recurrent events models for multiple hospitalizations and models for combined outcome of hospitalization and death.ResultsThere were 22 347 hospitalizations during a median follow-up of 23 months. Higher cumulative dose of intravenous iron was not associated with all-cause, cardiovascular or infectious hospitalizations [HR 0.97 (95% CI: 0.77-1.22) for all-cause hospitalizations comparing >2100 mg versus 0-900 mg of iron over 6 months]. Findings were similar in models examining the risk of hospitalizations in 1- and 3-month windows [HR 0.88 (95% CI: 0.79-0.99) and HR 0.88 (95% CI: 0.74-1.03), respectively] or the risk of combined outcome of hospitalization and death in the 6-month window [HR 0.98 (95% CI: 0.78-1.23)].ConclusionsHigher cumulative dose of intravenous iron may not be associated with increased risk of hospitalizations in hemodialysis patients. While clinical trials are needed, employing higher iron doses to reduce erythropoiesis-stimulating agents does not appear to increase morbidity in routine clinical care