5 research outputs found

    Atlanto-axial rotatory fixation in a girl with Spondylocarpotarsal synostosis syndrome

    Get PDF
    We report a 15-year-old girl who presented with spinal malsegmentation, associated with other skeletal anomalies. The spinal malsegmentation was subsequently discovered to be part of the spondylocarpotarsal synostosis syndrome. In addition, a distinctive craniocervical malformation was identified, which included atlanto-axial rotatory fixation. The clinical and the radiographic findings are described, and we emphasise the importance of computerised tomography to characterize the craniocervical malformation complex. To the best of our knowledge, this is the first clinical report of a child with spondylocarpotarsal synostosis associated with atlanto-axial rotatory fixation

    A Curricular Model for Simulation Within Orthopaedic Residency Training

    No full text
    Introduction:. American Board of Orthopaedic Surgery/American Council on GraduateMedical Education Residency Review Committee training requirements have necessitated the need for the adoption of simulation education into existing programmatic requirements. Current guidelines focus only on interns at a potentially significant cost to programs; both in total dollar amount and time. Methods:. The authors aim to provide a model that can maximize utility for all resident levels, manage cost by maximizing the use of cadaveric material, and allow integration of varied industry support. Results:. The Oregon Health & Science University Orthopaedic education program has developed a high-fidelity training curriculum that (1) is applicable to both junior and senior residents (2) has minimized the cost per resident with the reuse of cadaveric specimens and (3) has nurtured partnerships with industry stakeholders to reduce bias in training by collaborating with most major industry representatives. Conclusion:. The simulation curriculum outlined in this manuscript may serve as a reference for other programs and institutions to develop their own residency educational curriculum models

    Dynamic pressure–volume loop analysis by simultaneous real-time cardiovascular magnetic resonance and left heart catheterization

    No full text
    Abstract Background Left ventricular (LV) contractility and compliance are derived from pressure–volume (PV) loops during dynamic preload reduction, but reliable simultaneous measurements of pressure and volume are challenging with current technologies. We have developed a method to quantify contractility and compliance from PV loops during a dynamic preload reduction using simultaneous measurements of volume from real-time cardiovascular magnetic resonance (CMR) and invasive LV pressures with CMR-specific signal conditioning. Methods Dynamic PV loops were derived in 16 swine (n = 7 naïve, n = 6 with aortic banding to increase afterload, n = 3 with ischemic cardiomyopathy) while occluding the inferior vena cava (IVC). Occlusion was performed simultaneously with the acquisition of dynamic LV volume from long-axis real-time CMR at 0.55 T, and recordings of invasive LV and aortic pressures, electrocardiogram, and CMR gradient waveforms. PV loops were derived by synchronizing pressure and volume measurements. Linear regression of end-systolic- and end-diastolic- pressure–volume relationships enabled calculation of contractility. PV loops measurements in the CMR environment were compared to conductance PV loop catheter measurements in 5 animals. Long-axis 2D LV volumes were validated with short-axis-stack images. Results Simultaneous PV acquisition during IVC-occlusion was feasible. The cardiomyopathy model measured lower contractility (0.2 ± 0.1 mmHg/ml vs 0.6 ± 0.2 mmHg/ml) and increased compliance (12.0 ± 2.1 ml/mmHg vs 4.9 ± 1.1 ml/mmHg) compared to naïve animals. The pressure gradient across the aortic band was not clinically significant (10 ± 6 mmHg). Correspondingly, no differences were found between the naïve and banded pigs. Long-axis and short-axis LV volumes agreed well (difference 8.2 ± 14.5 ml at end-diastole, -2.8 ± 6.5 ml at end-systole). Agreement in contractility and compliance derived from conductance PV loop catheters and in the CMR environment was modest (intraclass correlation coefficient 0.56 and 0.44, respectively). Conclusions Dynamic PV loops during a real-time CMR-guided preload reduction can be used to derive quantitative metrics of contractility and compliance, and provided more reliable volumetric measurements than conductance PV loop catheters
    corecore