17 research outputs found

    Study of (3He, t) charge exchange reactions to isobaric analog states in inverse kinematics

    Full text link
    The transition between isobaric analog states (IAS) in the (3He, t) charge exchange reaction presents a unique opportunity to access the isospin structure of the nuclei. In this study not only the Fermi transition but also the Gamow-Teller (G-T) transition of the IAS reaction were investigated for the 13,14C(3He, t) and 17,18,19,20O(3He, t) reactions, in order to explore the neutron number dependence of the IAS reaction for the light neutron-rich nuclei. It was found that the G-T type IAS reaction also exhibited a significant dependence of the transition strength on the neutron number and the angular momentum configuration of the nuclei. Additionally, the inverse kinematics was also discussed for extracting the yields of the interested reaction channels in the proposed experiments on radioactive beams. The calculated triton yields demonstrated the capability of the proposed experiments to obtain meaningful results

    A CsI hodoscope on CSHINE for Bremsstrahlung {\gamma}-rays in Heavy Ion Reactions

    Full text link
    Bremsstrahlung γ\gamma production in heavy ion reactions at Fermi energies carries important physical information including the nuclear symmetry energy at supra-saturation densities. In order to detect the high energy Bremsstrahlung γ\gamma rays, a hodoscope consisting of 15 CsI(Tl) crystal read out by photo multiplier tubes has been built, tested and operated in experiment. The resolution, efficiency and linear response of the units to γ\gamma rays have been studied using radioactive source and (p,γ)({\rm p},\gamma) reactions. The inherent energy resolution of 1.6%+2%/Eγ1/21.6\%+2\%/E_{\gamma}^{1/2} is obtained. Reconstruction method has been established through Geant 4 simulations, reproducing the experimental results where comparison can be made. Using the reconstruction method developed, the whole efficiency of the hodoscope is about 2.6×10−42.6\times 10^{-4} against the 4π4\pi emissions at the target position, exhibiting insignificant dependence on the energy of incident γ\gamma rays above 20 MeV. The hodoscope is operated in the experiment of 86^{86}Kr + 124^{124}Sn at 25 MeV/u, and a full γ\gamma energy spectrum up to 80 MeV has been obtained.Comment: 9 pages, 19 figure

    Probing high-momentum component in nucleon momentum distribution by neutron-proton bremsstrahlung {\gamma}-rays in heavy ion reactions

    Full text link
    The high momentum tail (HMT) of nucleons, as a signature of the short-range correlations in nuclei, has been investigated by the high-energy bremsstrahlung γ\gamma rays produced in 86^{86}Kr + 124^{124}Sn at 25 MeV/u. The energetic photons are measured by a CsI(Tl) hodoscope mounted on the spectrometer CSHINE. The energy spectrum above 30 MeV can be reproduced by the IBUU model calculations incorporating the photon production channel from npnp process in which the HMTs of nucleons is considered. A non-zero HMT ratio of about 15%15\% is favored by the data. The effect of the capture channel np→dγnp \to d\gamma is demonstrated

    Revisit to the yield ratio of triton and 3^3He as an indicator of neutron-rich neck emission

    Full text link
    The neutron rich neck zone created in heavy ion reaction is experimentally probed by the production of the A=3A=3 isobars. The energy spectra and angular distributions of triton and 3^3He are measured with the CSHINE detector in 86^{86}Kr +208^{208}Pb reactions at 25 MeV/u. While the energy spectrum of 3^{3}He is harder than that of triton, known as "3^{3}He-puzzle", the yield ratio R(t/3He)R({\rm t/^3He}) presents a robust rising trend with the polar angle in laboratory. Using the fission fragments to reconstruct the fission plane, the enhancement of out-plane R(t/3He)R({\rm t/^3He}) is confirmed in comparison to the in-plane ratios. Transport model simulations reproduce qualitatively the experimental trends, but the quantitative agreement is not achieved. The results demonstrate that a neutron rich neck zone is formed in the reactions. Further studies are called for to understand the clustering and the isospin dynamics related to neck formation

    Molecular Analysis of Virulent Determinants of Enterovirus 71

    Get PDF
    Enterovirus 71 (EV71) is the most important causative agent of hand, foot and mouth disease (HFMD) in children. In most cases, it is a self-limiting illness. However some EV71 infectious cases can develop severe clinical outcomes, such as encephalitis, meningitis, poliomyelitis like paralysis, and even death. To identify the determinants of virulence, the deduced amino acid sequence of polyprotein and nucleotide sequence of 5′-NTR and 3′-NTR in 25 SC-EV71 strains (strains from severe cases) and 31 MC-EV71 strains (strains from mild cases) were analyzed. Results showed four amino acids on two positions (GlyP710/GlnP710/ArgP710 and GluP729) on the DE and EF loop of VP1, one (LysP930) on the surface of protease 2A and four nucleotides on three positions (GP272, UP488 and AP700/UP700) in the 5'-NTR region are associated with EV71 virulent phenotype. Predicted secondary structure of RNA using the consensus sequence of 5'-NTR by RNAStructure showed the mutation of nucleotide at position 488 in strain BJ08-Z004-3 (position 491 in prototype strain BrCr) can result in the discrepancy of an additional pair of nucleotides and thus change the stability of the second structure of IRES. Fragment base content analysis showed that in the region 696 to 714 bp at the 5'-NTR, where the AP700/UP700 was located, the nucleotide constitution ratios differed significantly between SC-EV71 and MC-EV71 strains. In conclusion, comparative genomic analysis showed that virulence of EV71 strains are mainly determined by the amino acids on two positions of VP1, one position of protease 2A and the nucleotides on three positions in 5'-NTR

    Seroprevalence of poliovirus antibodies before and after polio vaccine switch in 2012 and 2017 in Beijing

    No full text
    In 2000, China was declared polio-free. However, in 2018, wild poliovirus (WPV) was still endemic in two of its neighboring countries, making WPV importation and outbreak alarming possibilities. This study documents the seroprevalence of poliovirus antibodies before and after the polio vaccine switch in 2012 and 2017 in Beijing. Cross-sectional population-based serologic surveys were conducted in 2012 and 2017 in Beijing. The study subjects were selected from 10 different age groups (<1, 1–4, 5–9, 10–14, 15–19, 20–24, 25–29, 30–34, 35–39, and ≥40 y) using a multi-stage-stratified sampling method. Neutralizing antibody titers against poliovirus serotypes 1 (P1), 2 (P2), and 3 (P3) were assayed by World Health Organization standards. The seropositive rates (SR) and geometric mean titer (GMT) of the neutralizing antibodies were 91.71% and 1:130.26, respectively, for P1, 94.09% and 1:113.39, respectively, for P2, and 88.78% and 1:79.65, respectively, for P3 before the switch in 2012, and 87.78% and 1:108.93, respectively, for P1, and 81.67% and 1:70.56, respectively, for P3 after the switch in 2017, with a statistically significant difference for P1 and P3 between 2012 and 2017. The neutralizing antibodies for all poliovirus serotypes differed among different age and vaccination groups in both 2012 and 2017. After switching polio vaccines twice in 2014 and 2016, the P1 and P3 polio antibody levels were lower in 2017 than in 2012. The P2 antibody levels were determined from the first dose of IPV. The seroprevalence of poliovirus antibodies after adjustment of the immunization schedule of the polio vaccine on January 1, 2020, must be further monitored

    The investigation of a new fast timing system based on DRS4 waveform sampling system

    No full text
    In the study of nuclear structure, the fast timing technique can be used to measure the lifetime of excited states. In the paper, we have developed a new fast timing system, which is made up of two LaBr3:Ce detectors and a set of waveform sampling system. The sampling system based on domino ring sampler version 4 chip (DRS4) can digitize and store the waveform information of detector signal, with a smaller volume and higher timing accuracy, and the waveform data are performed by means of digital waveform analysis methods. The coincidence time resolution of the fast timing system for two annihilation 511 keV γ photon is 200ps (FWHM), the energy resolution is 3.5%@511 keV, and the energy linear response in the large dynamic range is perfect. Meanwhile, to verify the fast timing performance of the system, the 152Gd-21+ state form β+ decay of 152Eu source is measured. The measured lifetime is 45.3(±5.0)ps, very close to the value of the National Nuclear Data Center (NNDC: 46.2((±3.9)ps). The experimental results indicate that the fast timing system is capable of measuring the lifetime of dozens of ps. Therefore, the system can be widely used in the research of the fast timing technology. Keywords: Fast timing technique, LaBr3:Ce scintilator, Waveform sampling system, Excited state lifetim

    Anti-coincidence detector unit based on WLS fiber and SiPM readout

    No full text
    BackgroundComplete kinematic measurements in the medium or high-energy region is a common experimental method to study the structure and properties of exotic nuclides on the neutron-rich side. The experiment setup in the Cooling Storage Ring - Radioactive Ion Beam Line in Lanzhou (CSR-RIBLLII), a typical nuclear external target facility, comprises many detectors with different requirements. The anticoincidence (Veto) detector is an essential part of the external target facility for eliminating the interference of charged particles and measuring medium or high-energy neutrons with high reliability and performance by combining them with a neutron wall detector. The original Veto detector with photomultiplier (PMT) readouts has many disadvantages, such as low detection efficiency and poor uniformity, resulting in significant differences or contradictions between experimental and calculation results.PurposeThis study aims to upgrade the original Veto detector using wave length shifter fiber (WLS) and silicon photomultiplier (SiPM) to improve the detection efficiency of charged particles.MethodsFirstly, a new configuration for the anticoincidence Veto detector unit was designed and the detector thickness was increased by 5 mm compared to the previous Veto detector, resulting in a final thickness of 1 cm. The Veto detector was embedded with 15, 7, and 3 WLS fibers from both ends, and read using SiPM. Furthermore, to systematically explore the performance of the detector unit, a linear relationship was calibrated between the number of photons of the SiPMs and the number of Analog-to-Digital Converter (ADC) channels. This relationship was used to accurately calculate the threshold value, laying a foundation for calculating detection efficiency. Then, based on Multi-Wire Proportional Chamber (MWPC), a detection efficiency test platform was established, and time position conversion and track selection data analysis methods were developed as test methods. Finally, a detailed test on the whole and each part of the anticoincidence Veto detector unit was carried out on the MWPC test platform.ResultsTest results show the highest anticoincidence efficiencies of SiPMs at both ends for the Veto detector embedded with 15, 7, and 3 WLS fibers are 99.99%, 99.94%, and 99.82%, respectively; increased by over 22.74% compared with the original Veto detector.ConclusionsThe new Veto detector based on WLS fiber and SiPM readout meets the needs of the CSR-RIBLLII external target facility
    corecore