41 research outputs found

    Bacteriophage-Resistant Mutants in Yersinia pestis: Identification of Phage Receptors and Attenuation for Mice

    Get PDF
    Background: Bacteriophages specific for Yersinia pestis are routinely used for plague diagnostics and could be an alternative to antibiotics in case of drug-resistant plague. A major concern of bacteriophage therapy is the emergence of phageresistant mutants. The use of phage cocktails can overcome this problem but only if the phages exploit different receptors. Some phage-resistant mutants lose virulence and therefore should not complicate bacteriophage therapy. Methodology/Principal Findings: The purpose of this work was to identify Y. pestis phage receptors using site-directed mutagenesis and trans-complementation and to determine potential attenuation of phage-resistant mutants for mice. Six receptors for eight phages were found in different parts of the lipopolysaccharide (LPS) inner and outer core. The receptor for R phage was localized beyond the LPS core. Most spontaneous and defined phage-resistant mutants of Y. pestis were attenuated, showing increase in LD 50 and time to death. The loss of different LPS core biosynthesis enzymes resulted in the reduction of Y. pestis virulence and there was a correlation between the degree of core truncation and the impact on virulence. The yrbH and waaA mutants completely lost their virulence. Conclusions/Significance: We identified Y. pestis receptors for eight bacteriophages. Nine phages together use at least seven different Y. pestis receptors that makes some of them promising for formulation of plague therapeutic cocktails. Most phage-resistant Y. pestis mutants become attenuated and thus should not pose a serious problem for bacteriophag

    Nowy system drenażu zapewniający zrównoważony przepływ wody gruntowej w strefie fundamentów budynków wysokościowych

    No full text
    One of the problems with improving the stability of the structure during the construction of high-rise buildings on the territories adjacent to the sea or a river bed is to draw down the ground and seepage waters in the foundation, and solving this problem will help improve the stability of the structure in the final run. Aiming at solving this problem, a new structure of a three-stage combined drainage system was designed at Ts. Mirtskhulava Water Management Institute of Georgian Technical University (Georgian Patent #GE P2005, 3573 P) ensuring not only drawing down the ground water, but also regulating the surface and seepage waters in the building foundation. The goal of the study is to examine the water conductivity of the three-stage combined drainage system to improve the building stability and develop the methods of its hydraulic calculations.Jednym z problemów związanych z posadowieniem konstrukcji budynków wysokościowych na terenach przylegających do morza lub koryta rzeki jest przesiąkanie wody w strefę fundamentów. Rozwiązaniem tego problemu, które może poprawić stateczność danych konstrukcji w całym cyklu funkcjonowania budynku, jest odprowadzenie wody z gruntu, z otoczenia fundamentów. Mając na celu rozwiązanie tego problemu, w Gruzińskim Uniwersytecie Technicznym (GUT) zaprojektowano nową konstrukcję trójfazowego kombinowanego systemu drenażowego. Instytut Gospodarki Wodnej im. Mirtskhulavy GUT opatentował konstrukcję zapewniającą nie tylko odprowadzenie wód gruntowych, ale także regulację wód powierzchniowych i przesiąkowych do fundamentów budynku (gruziński patent GE P2005, 3573 P). Celem badania było zbadanie przepływu wody w trójfazowym kombinowanym systemie drenażowym w celu poprawy stabilności budynku i opracowanie metody jego obliczeń hydraulicznych

    A new radiation sensitive mutant of Escherichia coli K-12

    No full text
    corecore