183 research outputs found

    Improvement in the photoelectrochemical responses of PCBM/TiO2 electrode by electron irradiation

    Get PDF
    The photoelectrochemical (PEC) responses of electron-irradiated [6,6]-phenyl-C61-butyric acid methyl ester (PCBM)/TiO2 electrodes were evaluated in a PEC cell. By coating PCBM on TiO2 nanoparticle film, the light absorption of PCBM/TiO2 electrode has expanded to the visible light region and improved the PEC responses compared to bare TiO2 electrode. The PEC responses were further improved by irradiating an electron beam on PCBM/TiO2 electrodes. Compared to non-irradiated PCBM/TiO2 electrodes, electron irradiation increased the photocurrent density and the open-circuit potential of PEC cells by approximately 90% and approximately 36%, respectively at an optimum electron irradiation condition. The PEC responses are carefully evaluated correlating with the optical and electronic properties of electron-irradiated PCBM/TiO2 electrodes

    Small-sized flat-tip CNT emitters for miniaturized X-ray tubes

    Get PDF
    Small tip-type CNT emitters with the diameter of 0.8 mm were fabricated for miniaturized X-ray tubes. The CNT emitters were prepared by dropping CNTs and silver nanoparticles on a flat surface of a W metal tip followed by annealing at 800 • C for 2 h under vacuum. The CNT emitters exhibit good field emission properties with the threshold electric field of 1.15 V/μm and the field enhancement factor of 12,050. CNTs were well attached to a flat W tip surface without coating on the side plane of the tip, and thus beam divergence could be minimized. Consequently, a miniaturized X-ray tube with the inner diameter of 5 mm was successfully demonstrated using the tip-type CNT emitter. Nanostructured materials are widely used for electron emitters because of their good field-emission properties • C can induce a serious heating of the small X-ray tube. High operating temperature of miniaturized X-ray tubes limits the applications of the tubes, for example, to brachytherapy. Consequently, a cooling device is required for the operation, but the cooling device increases the size of the miniaturized X-ray tube. In this sense, CNT emitters are proper electron sources because electrons are generated through field emission, and hence the cold emission process does not increase the temperature of the X-ray tube. In addition, CNT emitters are also promising electron emitters for microfocus X-ray tube

    Small-Sized Flat-Tip CNT Emitters for Miniaturized X-Ray Tubes

    Get PDF
    Small tip-type CNT emitters with the diameter of 0.8 mm were fabricated for miniaturized X-ray tubes. The CNT emitters were prepared by dropping CNTs and silver nanoparticles on a flat surface of a W metal tip followed by annealing at 800°C for 2 h under vacuum. The CNT emitters exhibit good field emission properties with the threshold electric field of 1.15 V/μm and the field enhancement factor of 12,050. CNTs were well attached to a flat W tip surface without coating on the side plane of the tip, and thus beam divergence could be minimized. Consequently, a miniaturized X-ray tube with the inner diameter of 5 mm was successfully demonstrated using the tip-type CNT emitter

    Association between Workplace Risk Factor Exposure and Sleep Disturbance: Analysis of the 2nd Korean Working Conditions Survey

    Get PDF
    OBJECTIVES: Sleep is essential for human beings to live and work properly. This study was conducted to investigate the relationship between occupational exposures to workplace risk factors and sleep disturbance in Korean workers. METHODS: The data were drawn from the second Korean Working Conditions Survey (KWCS); a total of 7,112 paid workers were analyzed. The independent variables were occupational exposures such as physical, chemical, biological, and psychosocial risk factor in the workplace, and psychosocial risk factor was divided into five categories (job demand, job control, social support, job insecurity, lack of reward). We estimated the relationship between various occupational exposures and sleep disturbance using multivariate logistic regression analysis. RESULTS: The results showed that people who exposed to physical, chemical, biological, and psychosocial (high job demand, inadequate social support, lack of reward) risk factors were more likely to increase the risk of sleep disturbance. Furthermore, after adjusting for general and occupational characteristics, we found significant positive associations between exposures to physical (odds ratios [OR] 1.47, 95% confidence interval [CI] 1.05-2.07) and psychosocial (high job demand (OR 2.93, 95% CI 2.16-3.98), inadequate social support (OR 1.57, 95% CI 1.14-2.15), lack of reward (OR 1.45, 95% CI 1.08-1.96)) risk factors and sleep disturbance. CONCLUSION: These results suggest that occupational exposures to physical and psychosocial workplace risk factors are significantly related to sleep disturbance

    Vision Improvement with Refractive Correction Does Not Completely Exclude Major Eye Diseases: Analyses of Visually Impaired South Korean Population in the Korea National Health and Nutrition Examination Survey 2009–2011

    Get PDF
    Purpose. To investigate the association between vision improvement with refractive correction in the visually impaired eyes and the prevalence of ocular comorbidities in the South Korean population. Materials and Methods. The data of 24,620 individuals in the Korea National Health and Nutrition Examination Survey (KNHANES 2009–2011) were reviewed. Visual impairment was defined as a presenting visual acuity < 20/60. The participants with visual impairment in at least one eye were divided into 3 groups according to the best-corrected visual acuity (group 1: <20/30, group 2: ≥20/30 but <20/25, and group 3: ≥20/25). The prevalence of ocular comorbidities was estimated and compared between the three groups. Results. Visual impairment in at least one eye was found in 3031 individuals. Groups 1, 2, and 3 comprised 23.5%, 22.2%, and 54.3% of these visually impaired eyes, respectively. The prevalence of cataract, diabetic retinopathy, age-related macular degeneration, corneal opacity, blepharoptosis, and pterygium was similar to or even higher in group 2 compared to group 1. The prevalence of glaucoma and age-related macular degeneration was 5.40% and 11.39%, respectively, in group 2 and 3.31% and 3.76%, respectively, in group 3. Conclusions. Appropriate ophthalmologic examination is necessary even if people exhibit vision improvement after optical correction

    O2-tolerant CO dehydrogenase via tunnel redesign for the removal of CO from industrial flue gas

    Get PDF
    Ni???Fe carbon monoxide dehydrogenases (CODHs) are nearly diffusion-limited biocatalysts that oxidize CO. Their O2 sensitivity, however, is a major drawback for industrial applications. Here we compare the structures of a fast CODH with a high O2 sensitivity (ChCODH-II) and a slower CODH with a lower O2 sensitivity (ChCODH-IV) (Ch, Carboxydothermus hydrogenoformans). Some variants obtained by simple point mutations of the bottleneck residue (A559) in the gas tunnel showed 61???148-fold decreases in O2 sensitivity while maintaining high turnover rates. The variant structure A559W showed obstruction of one gas tunnel, and molecular dynamics supported the locked position of the mutated side chain in the tunnel. The variant was exposed to different gas mixtures, from simple synthetic gas to sophisticated real flue from a steel mill. Its catalytic properties remained unchanged, even at high O2 levels, and the efficiency was maintained for multiple cycles of CO detoxification/regeneration

    Anti-inflammatory effect of supercritical extract and its constituents from Ishige okamurae

    Get PDF
    The anti-inflammatory properties of the supercritical fluid extract of Ishige okamurae (SFEIO) on lipopolysaccharide (LPS)-stimulated murine RAW 264.7 macrophages. The lipid profile of the SFEIO, reviled the presence of palmitic acid (220.2 mg/g), linoleic acid (168.0 mg/g), and oleic acid (123.0 mg/g). SFEIO was found to exert it’s anti-inflammatory effects through inhibiting nitric oxide (NO), prostaglandin E2 (PGE2), inducible nitric oxide synthase (iNOS), cyclooxygenase-2 (COX-2), tumor necrosis factor (TNF)-α, interleukin (IL)-1β, and IL-6 production in LPS-stimulated RAW 264.7 cells, without inducing cytotoxicity. SFEIO did not effect on the LPS-induced p38 kinase phosphorylation, whereas it attenuated the extracellular-related signaling kinase (ERK) and c-Jun N-terminal kinase (JNK) phosphorylation. Furthermore, SFEIO inhibited the LPS-induced IκB-α degradation and p50 NF-κB activation. These results suggest that SFEIO exerts its anti-inflammatory effects in LPS-activated RAW 264.7 cells by down-regulating the activation of ERK, JNK, and NF-κB
    corecore