    Assessment of the kidneys: magnetic resonance angiography, perfusion and diffusion

    Get PDF
    Renal magnetic resonance (MR) imaging has undergone major improvements in the past several years. This review focuses on the technical basics and clinical applications of MR angiography (MRA) with the goal of enabling readers to acquire high-resolution, high quality renal artery MRA. The current role of contrast agents and their safe use in patients with renal impairment is discussed. In addition, an overview of promising techniques on the horizon for renal MR is provided. The clinical value and specific applications of renal MR are critically discussed

    Value of Diffusion-Weighted MR Imaging for the Detection of Nephritis

    Get PDF
    Purpose. To evaluate diffusion-weighted MR imaging (DWI-MRI) for the detection and assessment of infectious renal disease. Materials and Methods. Twenty-one patients with suspicious increased signal intensity of the kidneys on DWI sequences and corresponding ADC decrease were identified. Sixty patients without clinical signs of renal infection served as a control group. All patients were examined with the following sequences: EPI-DWI (0/400/800 s/mm2), T2w HASTE, and T1w VIBE after intravenous injection of Gd-chelate. Confirmation of renal infection was established on the basis of clinical criteria. T1w and T2w images were assessed and compared to DWI for the presence of altered signal, and the degree of the visibility of pathology was graded on an ordinal three-point scale. Results. In all 21 patients with positive DWI findings a renal infection could be confirmed. T2w imaging and contrast-enhanced T1w imaging displayed obvious pathologic signal in 3/21 (14%) and 11/19 (58%) patients and slightly pathologic signal in 17/21 (81%) and 7/19 (37%), respectively. The median visibility score of 2 for the DWI and the T1w images was significantly higher than the score of 1 for the T2w imaging, (DWI versus T2w) and (T1w versus T2w). Conclusion. DWI of the kidneys seems to be highly sensitive for the detection of infections within the kidney

    Steady state vascular imaging with extracellular gadobutrol: evaluation of the additional diagnostic benefit in patients who have undergone a peripheral magnetic resonance angiography protocol

    Get PDF
    Background: To evaluate the feasibility and additional diagnostic benefit of a high-resolution steady state 3D-volume interpolated breath-hold exam (VIBE) sequence between a continuous table movement (CTM) MR angiography of the entire runoff vasculature and a time-resolved (TWIST) MRA of the calves. Methods: In this retrospective IRB approved study 224 patients (72 women, 152 men, mean age 67.29 ± 13.9) were included who had undergone a low-dose MR angiographic protocol at 3T (Siemens TimTrio) after injection of 0.1 mmol/kg gadobutrol including a CTM MRA, a time-resolved MRA of the calf station and a steady state 3D VIBE sequence prior to the time-resolved MRA. One board-certified radiologist rated the image quality of the steady state VIBE sequences on an ordinal three point scale (excellent, good, poor) and analyzed the images for additional diagnostic findings of and beyond the vascular system in comparison to the CTM MRA and the time-resolved MRA. Descriptive statistics and demographic patient data were used for further evaluation. Results: The image quality of the steady state imaging of the pelvis, upper and lower leg was excellent in up to 88%, 84% and 47%, respectively, while poor image quality was only detected in the upper (2%) and lower leg (6%). An additional diagnostic benefit was found in 44% of the patients overall. The most common relevant pathologies included inflammatory processes of the soft tissues (26%), thrombi (14%), abscesses (13%) and tumors (11%). In subgroups of patients above the age of 60, 65, 70, 75 and 80 years an additional pathology was found in 50% 33%, 44%, 65% and 58%, respectively. There was no significant difference in terms of additional findings between men and women (46% and 39%, p > 0.05) and inpatients and outpatients (42% and 45%, p > 0.05). Conclusion: Steady state imaging is also feasible with extracellular contrast agents with good image quality yielding additional diagnostic findings in up to 44% and above in patients older than 60 years of age irrespective of gender or patient status. Given the short acquisition time of 4 minutes this sequence could be added to all peripheral MRA exams

    Gadobutrol in Renally Impaired Patients: Results of the GRIP Study.

    Get PDF
    OBJECTIVE: The aim of this study was to assess the potential risk of gadobutrol-enhanced magnetic resonance imaging (MRI) in patients with moderate to severe renal impairment for the development of nephrogenic systemic fibrosis (NSF). MATERIALS AND METHODS: We performed a prospective, international, multicenter, open-label study in 55 centers. Patients with moderate to severe renal impairment scheduled for any gadobutrol-enhanced MRI were included. All patients received a single intravenous bolus injection of gadobutrol at a dose of 0.1 mmol/kg body weight. The primary target variable was the number of patients who develop NSF within a 2-year follow-up period. RESULTS: A total of 908 patients were enrolled, including 586 with moderate and 284 with severe renal impairment who are at highest risk for developing NSF. The mean time since renal disease diagnosis was 1.83 and 5.49 years in the moderate and severe renal impairment cohort, respectively. Overall, 184 patients (20.3%) underwent further contrast-enhanced MRI with other gadolinium-based contrast agents within the 2-year follow-up. No patient developed symptoms conclusive of NSF. CONCLUSIONS: No safety concerns with gadobutrol in patients with moderate to severe renal impairment were identified. There were no NSF cases

    Comparison of Dynamic and Liver-Specific Gadoxetic Acid Contrast-Enhanced MRI versus Apparent Diffusion Coefficients

    Get PDF
    Hepatic lesions often present diagnostic connundrums with conventional MR techniques. Hepatobiliary phase contrast-enhanced imaging with gadoxetic acid can aid in the characterization of such lesions. However, quantitative measures describing late-phase enhancement must be assessed relative to their accuracy of hepatic lesion classification.To compare quantitative parameters in gadoxetic acid contrast-enhanced dynamic and hepatobiliary phase imaging versus apparent diffusion coefficients in hepatic lesion characterization.57 patients with focal hepatic lesions on gadoxetic acid MR were included. Lesion enhancement at standard post-contrast time points and in the hepatobiliary phase (HB; 15 and 25 minutes post-contrast) was assessed via calculation of contrast (CR) and enhancement ratios (ER). Apparent diffusion coefficient (ADC) values were also obtained. Values for these parameters were compared among lesions and ROC analyses performed.HB enhancement was greatest with FNH and adenomas. HB ER parameters but not HB CR could distinguish HCC from benign entities (0.9 ER ROC AUC versus 0.5 CR ROC AUC). There was no statistically significant difference found between the 15 and 25 minutes HB time points in detection of any lesion (p>0.4). ADC values were statistically significantly higher with hemangiomas (p<0.05) without greater accuracy in lesion detection relative to HB phase parameters.Hepatobiliary phase gadoxetic acid contrast-enhanced MR characterizes focal hepatic lesions more accurately than ADC and conventional dynamic post-contrast time point enhancement parameters. ER values are generally superior to CR. No discernible benefit of 25 minute versus 15 minute delayed imaging is demonstrated

    Implementation of Dual-Source RF Excitation in 3 T MR-Scanners Allows for Nearly Identical ADC Values Compared to 1.5 T MR Scanners in the Abdomen

    Get PDF
    Background: To retrospectively and prospectively compare abdominal apparent diffusion coefficient (ADC) values obtained within in a 1.5 T system and 3 T systems with and without dual-source parallel RF excitation techniques. Methodology/Principal Findings: After IRB approval, diffusion-weighted (DW) images of the abdomen were obtained on three different MR systems (1.5 T, a first generation 3 T, and a second generation 3 T which incorporates dual-source parallel RF excitation) on 150 patients retrospectively and 19 volunteers (57 examinations total) prospectively. Seven regions of interest (ROI) were throughout the abdomen were selected to measure the ADC. Statistical analysis included independent two-sided t-tests, Mann-Whitney U tests and correlation analysis. In the DW images of the abdomen, mean ADC values were nearly identical with nonsignificant differences when comparing the 1.5 T and second generation 3 T systems in all seven anatomical regions in the patient population and six of the seven in the volunteer population (p.0.05 in all distributions). The strength of correlation measured in the volunteer population between the two scanners in the kidneys ranged from r = 0.64–0.88 and in the remaining regions (besides the spleen), r.0.85. In the patient population the first generation 3 T scanner had different mean ADC values with significant differences (p,0.05) compared to the other two scanners in each of the seven distributions. In the volunteer population, the kidneys shared similar ADC mean values in comparison to the other two scanners with nonsignificant differences

    Fast Inner-Volume Imaging of the Lumbar Spine with a Spatially Focused Excitation Using a 3D-TSE Sequence

    No full text
    Rationale and Objectives: The purpose of this study was to evaluate the feasibility and technical quality of a zoomed three-dimensional (3D) turbo spin-echo (TSE) sampling perfection with application optimized contrasts using different flip-angle evolutions (SPACE) sequence of the lumbar spine. Materials and Methods: In this prospective feasibility study, nine volunteers underwent a 3-T magnetic resonance examination of the lumbar spine including 1) a conventional 3D T2-weighted (T2w) SPACE sequence with generalized autocalibrating partially parallel acquisition technique acceleration factor 2 and 2) a zoomed 3D T2w SPACE sequence with a reduced field of view (reduction factor 2). Images were evaluated with regard to image sharpness, signal homogeneity, and the presence of artifacts by two experienced radiologists. For quantitative analysis, signal-to-noise ratio (SNR) values were calculated. Results: Image sharpness of anatomic structures was statistically significantly greater with zoomed SPACE (P < .0001), whereas the signal homogeneity was statistically significantly greater with conventional SPACE (cSPACE; P = .0003). There were no statistically significant differences in extent of artifacts. Acquisition times were 8:20 minutes for cSPACE and 6:30 minutes for zoomed SPACE. Readers 1 and 2 selected zSPACE as the preferred sequence in five of nine cases. In two of nine cases, both sequences were rated as equally preferred by both the readers. SNR values were statistically significantly greater with cSPACE. Conclusions: In comparison to a cSPACE sequences, zoomed SPACE imaging of the lumbar spine provides sharper images in conjunction with a 25% reduction in acquisition time
    • …