10 research outputs found

    Global Variations in the Mineral Content of Bottled Still and Sparkling Water and a Description of the Possible Impact on Nephrological and Urological Diseases

    Get PDF
    Kidney stone disease (KSD) is a complex disease. Besides the high risk of recurrence, its association with systemic disorders contributes to the burden of disease. Sufficient water intake is crucial for prevention of KSD, however, the mineral content of water might influence stone formation, bone health and cardiovascular (CVD) risk. This study aims to analyse the variations in mineral content of bottled drinking water worldwide to evaluate the differences and describes the possible impact on nephrological and urological diseases. The information regarding mineral composition (mg/L) on calcium, bicarbonate, magnesium, sodium and sulphates was read from the ingredients label on water bottles by visiting the supermarket or consulting the online shop. The bottled waters in two main supermarkets in 21 countries were included. The evaluation shows that on a global level the mineral composition of bottled drinkable water varies enormously. Median bicarbonate levels varied by factors of 12.6 and 57.3 for still and sparkling water, respectively. Median calcium levels varied by factors of 18.7 and 7.4 for still and sparkling water, respectively. As the mineral content of bottled drinking water varies enormously worldwide and mineral intake through water might influence stone formation, bone health and CVD risk, urologists and nephrologists should counsel their patients on an individual level regarding water intake

    Could the region you live in prevent or precipitate kidney stone formation due to mineral intake through tap water? An analysis of nine distribution regions in Flanders

    No full text
    Objectives: To analyse the mineral content of tap water in Flanders and assess if the region one lives in could prevent or precipitate stone formation due to a difference in mineral content. Methods: Data from six water companies providing tap water to nine regions in Flanders regarding calcium, magnesium, potassium, sodium and sulphate content in tap water was retrieved. Minimum and maximum values were collected and compared between the different geographical regions. Results: The highest calcium level was found in region 9 with a value of 157.0 mg/L, which is almost 10 times the value found in region 8 (16.1 mg/L). Region 6 had the highest magnesium (31.8 mg/L), potassium (30.5 mg/L), sodium (126.6 mg/L) and sulphate (218.5 mg/L) levels. The lowest level of magnesium (2.7 mg/L) was found in region 1, which was almost 12 times lower as in Region 6. Region 9 had the lowest level of potassium (1.5 mg/L), which is a factor 20 lower than Region 6. The lowest sodium and sulphate levels were found in region 8 (6.8 mg/L and 3.0 mg/L), respectively. The difference between the highest and lowest level of sulphate was a factor 70. Conclusion: There is a broad range in the minerals found in tap water between the different production sites in the nine distribution regions in Flanders. However, due to the high standards tap water has to meet in Flanders, the region one lives in will not lead to a higher or lower risk of kidney stone formation if the advised 2 to 3 L per day are consumed

    Can operator-controlled imaging reduce fluoroscopy time during flexible ureterorenoscopy?

    No full text
    Introduction Fluoroscopy is routinely used during ureterorenoscopy. According to the ‘As Low As Reasonably Achievable’ (ALARA) principle, radiation exposure should be kept as low as reasonably achievable to decrease the risk of negative long-term effects of radiation for patients and medical staff. This study aims to assess if operator-controlled imaging during flexible ureterorenoscopy for nephrolithiasis could reduce fluoroscopy time when compared to radiographer-controlled imaging. Material and methods This study was a bicentric, retrospective comparison between patients treated for nephrolithiasis with flexible ureterorenoscopy with either operator-controlled imaging or radiogra-pher-controlled imaging. A total of 100 patients were included, 50 were treated with operator-controlled imaging and 50 with radiographer-controlled imaging. Patients undergoing flexible ureterorenoscopy with a total stone burden <20 mm and data on radiation exposure were included. Patient characteris-tics, stone characteristics, surgical details and fluoroscopy time were recorded for each patient and both groups were compared. Patient data were expressed as median. A 2-sided p-value <0.005 was considered statistically significant. Results This study found no significant differences between both groups regarding the patient and stone characteristics. However, it found a significant shorter fluoroscopy time in the operator-controlled imaging group of 33.5 seconds (IQR 16.0–70.0) compared to 57.0 seconds (IQR 36.8–95.3) in the radiographer-controlled imaging group (p = 0.001). Conclusions This study shows that operator-controlled imaging in flexible ureterorenoscopy could reduce fluoroscopy time when compared to radiographer-controlled imaging. Operator-controlled imaging might therefore allow urologists to perform ureterorenoscopy with greater independence while ad-ditionally reducing fluoroscopy time and its consequent negative effects for medical staff and patients

    Laparoscopic cryoablation for small renal masses: Oncological outcomes at 5-year follow-up

    No full text
    Objective: To evaluate the oncological outcome at 5-year follow-up after laparoscopic cryoablation (LCA) for small renal masses (SRMs), as there is an increasing interest in ablative therapy for cT1a renal tumours due to the rising incidence of SRMs, the trend towards minimally invasive nephron-sparing treatments, and the ageing population. Patients and methods: Between 2004 and 2015, 233 consecutive LCA were performed in 219 patients for SRMs at two referral centres. We only included those patients with ≥5 years of follow-up (n = 165) in a prospectively maintained database. A descriptive analysis was conducted for pre-, peri- and postoperative characteristics. A Kaplan–Meier analysis assessed overall (OS), disease-specific (DSS), and recurrence-free survival (RFS). Results: The median (interquartile range [IQR]) age of our patient cohort was 68 (60.5–76) years. The median (IQR) body mass index was 26.2 (23.8–29) kg/m2, and the median (IQR) Charlson Comorbidity Index score corrected for age was 4 (2.5–6). The median (IQR) tumour diameter was 28 (21–33) mm. In all, 15% developed a complication in the first 30 days after LCA, of which 1% had a major complication (Clavien–Dindo Grade ≥III). The median (IQR) preoperative estimated glomerular filtration rate (eGFR) was 82.5 (65–93.75) mL/min/1.73 m2. The median eGFR decreased by 16.4% and 15.2% at the 3-month and 5-year follow-up, respectively. Persistence was found in 1%, local recurrence in 2%, and systemic progression in 4%. The OS, DSS, and RFS were 74%, 96.9% and 95.4%, respectively. Conclusion: LCA is a safe and effective treatment for SRMs in selected cases and shows good oncological outcomes after 5 years of follow-up, with only 1% developing a major complication

    Renal biopsies performed before versus during ablation of T1 renal tumors: implications for prevention of overtreatment and follow-up

    No full text
    Purpose: To assess the difference between renal mass biopsy (RMB) performed either before or during the ablation procedure. Methods: A retrospective multicenter study was performed in patients with a cT1 renal mass treated with ablation between January 2007 and July 2019, including a search in the national pathology database for patients with a RMB planned for ablation. Patient and tumor characteristics and information on malignant, benign, and non-diagnostic biopsy results were collected to establish rates of overtreatment and number of ablations avoided in case of benign or non-diagnostic histology. Results: RMB was performed in 714 patients, of which 231 patients received biopsy before planned ablation, and 483 patients at the time of ablation. Pathology results before ablation were malignant in 63% (145/231), benign in 20% (46/231) and non-diagnostic in 17% (40/231). Pathology results at the time of ablation were malignant in 67.5% (326/483), benign in 16.8% (81/483) and non-diagnostic in 15.7% (76/483), leading to a total of 32.5% of ablation of benign or non-diagnostic lesions. Of the patients with a benign biopsy obtained before ablation, 80.4% (37/46) chose not to undergo ablation. Patients with inconclusive biopsy before planned ablation chose an informed individualized approach including ablation, repeated biopsy, or no intervention in 56%, 34% and 10%. Conclusion: This study emphasizes the importance of obtaining a biopsy prior to the ablation procedure in a separate session to lower the rate of potentially unnecessary ablations

    How reliable is endoscopic stone recognition?: A comparison between visual stone identification and formal stone analysis

    No full text
    Objective: To assess the diagnostic accuracy and intra-observer agreement of endoscopic stone recognition (ESR) compared with formal stone analysis. Introduction: Stone analysis is a corner stone in the prevention of stone recurrence. Although X-ray diffraction (XRD) and infrared spectroscopy are the recommended techniques for reliable formal stone analysis, this is not always possible, and the process takes time and is costly. ESR could be an alternative, as it would give immediate information on stone composition. Materials and Methods: Fifteen endourologists predicted stone composition based on 100 videos from ureterorenoscopy. Diagnostic accuracy was evaluated by comparing the prediction from visual assessment with stone analysis by XRD. After 30 days, the videos were reviewed again in a random order to assess intra-observer agreement. Results: The median diagnostic accuracy for calcium oxalate monohydrate was 54% in questionnaire 1 (Q1) and 59% in questionnaire 2 (Q2), whereas calcium oxalate dihydrate had a median diagnostic accuracy of 75% in Q1 and 50% in Q2. The diagnostic accuracy for calcium hydroxyphosphate was 10% in Q1 and 13% in Q2. The median diagnostic accuracy for calcium hydrogen phosphate dihydrate and calcium magnesium phosphate was 0% in both questionnaires. The median diagnostic accuracy for magnesium ammonium phosphate was 20% in Q1 and 40% in Q2. The median diagnostic accuracy for uric acid was 22% in both questionnaires. Finally, there was a diagnostic accuracy of 60% in Q1 and 80% in Q2 for cystine. The intra-observer agreement ranged between 45% and 72%. Conclusion: Diagnostic accuracy of ESR is limited and intra-observer agreement is below the threshold of acceptable agreement

    The Uniform grading tooL for flexIble ureterorenoscoPes (TULIP-tool): a Delphi consensus project on standardised evaluation of flexible ureterorenoscopes

    No full text
    Objective: To develop a standardised tool to evaluate flexible ureterorenoscopes (fURS). Materials and Methods: A three-stage consensus building approach based on the modified Delphi technique was performed under guidance of a steering group. First, scope- and user-related parameters used to evaluate fURS were identified through a systematic scoping review. Then, the main categories and subcategories were defined, and the expert panel was selected. Finally, a two-step modified Delphi consensus project was conducted to firstly obtain consensus on the relevance and exact definition of each (sub)category necessary to evaluate fURS, and secondly on the evaluation method (setting, used tools and unit of outcome) of those (sub)categories. Consensus was reached at a predefined threshold of 80% high agreement. Results: The panel consisted of 30 experts in the field of endourology. The first step of the modified Delphi consensus project consisted of two questionnaires with a response rate of 97% (n = 29) for both. Consensus was reached for the relevance and definition of six main categories and 12 subcategories. The second step consisted of three questionnaires (response rate of 90%, 97% and 100%, respectively). Consensus was reached on the method of measurement for all (sub)categories. Conclusion: This modified Delphi consensus project reached consensus on a standardised grading tool for the evaluation of fURS – The Uniform grading tooL for flexIble ureterorenoscoPes (TULIP) tool. This is a first step in creating uniformity in this field of research to facilitate future comparison of outcomes of the functionality and handling of fURS

    The Uniform grading tooL for flexIble ureterorenoscoPes (TULIP-tool): a Delphi consensus project on standardised evaluation of flexible ureterorenoscopes

    No full text
    OBJECTIVE: To develop a standardised tool to evaluate flexible ureterorenoscopes (fURS). MATERIALS AND METHODS: A three-stage consensus building approach based on the modified Delphi technique was performed under guidance of a steering group. First, scope- and user-related parameters used to evaluate fURS were identified through a systematic scoping review. Then, the main categories and subcategories were defined, and the expert panel was selected. Finally, a two-step modified Delphi consensus project was conducted to firstly obtain consensus on the relevance and exact definition of each (sub)category necessary to evaluate fURS, and secondly on the evaluation method (setting, used tools and unit of outcome) of those (sub)categories. Consensus was reached at a predefined threshold of 80% high agreement. RESULTS: The panel consisted of 30 experts in the field of endourology. The first step of the modified Delphi consensus project consisted of two questionnaires with a response rate of 97% (n = 29) for both. Consensus was reached for the relevance and definition of six main categories and 12 subcategories. The second step consisted of three questionnaires (response rate of 90%, 97% and 100%, respectively). Consensus was reached on the method of measurement for all (sub)categories. CONCLUSION: This modified Delphi consensus project reached consensus on a standardised grading tool for the evaluation of fURS - The Uniform grading tooL for flexIble ureterorenoscoPes (TULIP) tool. This is a first step in creating uniformity in this field of research to facilitate future comparison of outcomes of the functionality and handling of fURS
    corecore