3 research outputs found

    Sleep monitoring using ear-centered setups: Investigating the influence from electrode configurations.

    Get PDF
    Modern sleep monitoring development is shifting towards the use of unobtrusive sensors combined with algorithms for automatic sleep scoring. Many different combinations of wet and dry electrodes, ear-centered, forehead-mounted or headband-inspired designs have been proposed, alongside an ever growing variety of machine learning algorithms for automatic sleep scoring. OBJECTIVE: Among candidate positions, those in the facial area and around the ears have the benefit of being relatively hairless, and in our view deserve extra attention. In this paper, we seek to determine the limits to sleep monitoring quality within this spatial constraint. METHODS: We compare 13 different, realistic sensor setups derived from the same data set and analysed with the same pipeline. RESULTS: All setups which include both a lateral and an EOG derivation show similar, state-of-the-art performance, with average Cohen's kappa values of at least 0.80. CONCLUSION: If large electrode distances are used, positioning is not critical for achieving large sleep-related signal-to-noise-ratio, and hence accurate sleep scoring. SIGNIFICANCE: We argue that with the current competitive performance of automated staging approaches, there is a need for establishing an improved benchmark beyond current single human rater scoring

    A continuous-time delta-sigma ADC for portable ultrasound scanners

    No full text
    A fully differential fourth-order 1-bit continuous-time delta-sigma ADC designed in a 65nm process for portable ultrasound scanners is presented in this paper. The circuit design, implementation and measurements on the fabricated die are shown. The loop filter consists of RC-integrators, programmable capacitor arrays, resistors and voltage feedback DACs. The quantizer contains a pulse generator, a high-speed clocked comparator and a pull-down clocked latch to ensure constant delay in the feedback loop. Using this implementation, a small and low-power solution required for portable ultrasound scanner applications is achieved. The converter has a supply voltage of 1.2V, a bandwidth of 10MHz and an oversampling ratio of 16 leading to an operating frequency of 320MHz. The design occupies a die area of 0.0175mm2. Simulations with extracted parasitics show a SNR of 45.2dB and a current consumption of 489 µA. However, by adding a model of the measurement setup used, the performance degrades to 42.1dB. The measured SNR and current consumption are 41.6dB and 495 µA, which closely fit with the expected simulations. Several dies have been measured, and an estimation of the die spread distribution is given
    corecore