324 research outputs found
A nearly optimal preconditioner for the Navier-Stokes equations
We present a preconditioner for the linearised Navier-Stokes equations which is based on the combination of fast transform approximation of an advection diffusion problem together with the recently introduced '' preconditioner of Elman (SIAM J. Sci. Comput. 20 pp. 1299-1316, 1999). The resulting preconditioner when combined with an appropriate Krylov subspace iteration method yields the solution in a number of iterations which appears to be independent of the Reynolds number provided a mesh Peclet number restriction holds, and depends only mildly on the mesh size. The preconditioner is particularly appropriate for problems involving a primary flow direction
Psychosocial functioning and intelligence both partly explain socioeconomic inequalities in premature death. A population-based male cohort study
The possible contributions of psychosocial functioning and intelligence differences to socioeconomic status (SES)-related inequalities in premature death were investigated. None of the previous studies focusing on inequalities in mortality has included measures of both psychosocial functioning and intelligence.The study was based on a cohort of 49 321 men born 1949-1951 from the general community in Sweden. Data on psychosocial functioning and intelligence from military conscription at ∼18 years of age were linked with register data on education, occupational class, and income at 35-39 years of age. Psychosocial functioning was rated by psychologists as a summary measure of differences in level of activity, power of initiative, independence, and emotional stability. Intelligence was measured through a multidimensional test. Causes of death between 40 and 57 years of age were followed in registers.The estimated inequalities in all-cause mortality by education and occupational class were attenuated with 32% (95% confidence interval: 20-45%) and 41% (29-52%) after adjustments for individual psychological differences; both psychosocial functioning and intelligence contributed to account for the inequalities. The inequalities in cardiovascular and injury mortality were attenuated by as much as 51% (24-76%) and 52% (35-68%) after the same adjustments, and the inequalities in alcohol-related mortality were attenuated by up to 33% (8-59%). Less of the inequalities were accounted for when those were measured by level of income, with which intelligence had a weaker correlation. The small SES-related inequalities in cancer mortality were not attenuated by adjustment for intelligence.Differences in psychosocial functioning and intelligence might both contribute to the explanation of observed SES-related inequalities in premature death, but the magnitude of their contributions likely varies with measure of socioeconomic status and cause of death. Both psychosocial functioning and intelligence should be considered in future studies
Self-organization in systems of self-propelled particles
We investigate a discrete model consisting of self-propelled particles that
obey simple interaction rules. We show that this model can self-organize and
exhibit coherent localized solutions in one- and in two-dimensions.In
one-dimension, the self-organized solution is a localized flock of finite
extent in which the density abruptly drops to zero at the edges.In
two-dimensions, we focus on the vortex solution in which the particles rotate
around a common center and show that this solution can be obtained from random
initial conditions, even in the absence of a confining boundary. Furthermore,
we develop a continuum version of our discrete model and demonstrate that the
agreement between the discrete and the continuum model is excellent.Comment: 4 pages, 5 figure
Reaction time and incident cancer: 25 years of follow-up of study members in the UK Health and Lifestyle Survey
<b>Objectives</b><p></p>
To investigate the association of reaction time with cancer incidence.<p></p>
<b>Methods</b><p></p>
6900 individuals aged 18 to 94 years who participated in the UK Health and Lifestyle Survey in 1984/1985 and were followed for a cancer registration for 25 years.<p></p>
<b>Results</b><p></p>
Disease surveillance gave rise to 1015 cancer events from all sites. In general, there was essentially no clear pattern of association for either simple or choice reaction time with cancer of all sites combined, nor specific malignancies. However, selected associations were found for lung cancer, colorectal cancer and skin cancer.<p></p>
<b>Conclusions</b><p></p>
In the present study, reaction time and its components were not generally related to cancer risk
Properties of layer-by-layer vector stochastic models of force fluctuations in granular materials
We attempt to describe the stress distributions of granular packings using
lattice-based layer-by-layer stochastic models that satisfy the constraints of
force and torque balance and non-tensile forces at each site. The inherent
asymmetry in the layer-by-layer approach appears to lead to an asymmetric force
distribution, in disagreement with both experiments and general symmetry
considerations. The vertical force component probability distribution is robust
and in agreement with predictions of the scalar q model while the distribution
of horizontal force components is qualitatively different and depends on the
details of implementation.Comment: 18 pages, 12 figures (with subfigures), 1 table. Uses revtex,
epsfig,subfigure, and cite. Submitted to PRE. Plots have been bitmapped.
High-resolution version is available. Email [email protected] or
download from http://rainbow.uchicago.edu/~mbnguyen/research/vm.htm
Hampered PdO Redox Dynamics by Water Suppresses Lean Methane Oxidation over Realistic Palladium Catalysts
By use of operando spectroscopies under cycling reaction conditions, water is shown to hamper the redox dynamics of realistic palladium oxide nanoparticles dispersed onto alumina and hydrophobic zeolite supports thereby lowering the activity for total oxidation of methane. Water adsorption forms hydroxyl ad-species that block the methane and oxygen dissociation and seem to prevent lattice oxygen to take part in the methane oxidation. The main catalytic action is thus proposed to shift from the Mars-van Krevelen mechanism in dry conditions to a slower route that relies on Langmuir-Hinshelwood type of steps in wet conditions. This key finding has clear implications on catalyst design for low-temperature gas combustion emission control
Isostatic phase transition and instability in stiff granular materials
In this letter, structural rigidity concepts are used to understand the
origin of instabilities in granular aggregates. It is shown that: a) The
contact network of a noncohesive granular aggregate becomes exactly isostatic
in the limit of large stiffness-to-load ratio. b) Isostaticity is responsible
for the anomalously large susceptibility to perturbation of these systems, and
c) The load-stress response function of granular materials is critical
(power-law distributed) in the isostatic limit. Thus there is a phase
transition in the limit of intinitely large stiffness, and the resulting
isostatic phase is characterized by huge instability to perturbation.Comment: RevTeX, 4 pages w/eps figures [psfig]. To appear in Phys. Rev. Let
Strain-free bulk-like GaN grown by hydride-vapor-phase-epitaxy on two-step epitaxial lateral overgrown GaN template
Crack-free bulk-like GaN with high crystalline quality has been obtained by hydride-vapor-phase-epitaxy (HVPE)growth on a two-step epitaxial lateral overgrown GaN template on sapphire. During the cooling down stage, the as-grown 270-μm-thick GaN layer was self-separated from the sapphire substrate. Plan-view transmission electron microscopyimages show the dislocation density of the free-standing HVPE-GaN to be ∼2.5×10 exp 7  cm exp −2 on the Ga-polar face. A low Ga vacancy related defect concentration of about 8×10 exp 15 cm exp−3 is extracted from positron annihilation spectroscopy data. The residual stress and the crystalline quality of the material are studied by two complementary techniques. Low-temperature photoluminescence spectra show the main neutral donor bound exciton line to be composed of a doublet structure at 3.4715 (3.4712) eV and 3.4721 (3.4718) eV for the Ga- (N-) polar face with the higher-energy component dominating. These line positions suggest virtually strain-free material on both surfaces with high crystalline quality as indicated by the small full width at half maximum values of the donor bound exciton lines. The E1(TO) phonon mode position measured at 558.52 cm exp −1 (Ga face) by infrared spectroscopic ellipsometry confirms the small residual stress in the material, which is hence well suited to act as a lattice-constant and thermal-expansion-coefficient matched substrate for further homoepitaxy, as needed for high-quality III-nitride device applications.Peer reviewe
Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children
BACKGROUND: Exhaled nitric oxide (NO) measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now, most measurements have been done with stationary, chemiluminescence-based NO analysers, which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary health care. In this study, the performance of a new electrochemical hand-held device for exhaled NO measurements (NIOX MINO) was compared with a standard stationary chemiluminescence unit (NIOX). METHODS: A total of 71 subjects (6–60 years; 36 males), both healthy controls and atopic patients with and without asthma were included. The mean of three approved exhalations (50 ml/s) in each device, and the first approved measurement in the hand-held device, were compared with regard to NO readings (Bland-Altman plots), measurement feasibility (success rate with 6 attempts) and repeatability (intrasubject SD). RESULTS: Success rate was high (≥ 84%) in both devices for both adults and children. The subjects represented a FE(NO )range of 8–147 parts per billion (ppb). When comparing the mean of three measurements (n = 61), the median of the intrasubject difference in exhaled NO for the two devices was -1.2 ppb; thus generally the hand-held device gave slightly higher readings. The Bland-Altman plot shows that the 95% limits of agreement were -9.8 and 8.0 ppb. The intrasubject median difference between the NIOX and the first approved measurement in the NIOX MINO was -2.0 ppb, and limits of agreement were -13.2 and 10.2 ppb. The median repeatability for NIOX and NIOX MINO were 1.1 and 1.2 ppb, respectively. CONCLUSION: The hand-held device (NIOX MINO) and the stationary system (NIOX) are in clinically acceptable agreement both when the mean of three measurements and the first approved measurement (NIOX MINO) is used. The hand-held device shows good repeatability, and it can be used successfully on adults and most children. The new hand-held device will enable the introduction of exhaled NO measurements into the primary health care
- …