    Development and Validation of a LC-MS/MS Method for the Simultaneous Estimation of Amlodipine and Valsartan in Human Plasma: Application to a Bioequivalence Study

    No full text
    A reliable, simple, and robust liquid chromatography-tandem mass spectro-metric (LC-MS/MS) method has been developed and validated that employs solid-phase extraction for the simultaneous estimation of amlodipine and valsartan in human K3EDTA plasma using amlodipine-d4 and valsartan-d9 as internal standards. Chromatographic separation of amlodipine and valsartan was achieved on the Luna C18 (2)100A (150 x 4.6 mm, 5 μm) column using acetonitrile: 5 mM ammonium formate solution (80:20, v/v) as the mobile phase at a flow rate of 0.8 mL/min in isocratic mode. Quantification was achieved using an electrospray ion interface operating in positive mode, under multiple reaction monitoring (MRM) conditions. The assay was found to be linear over the range of 0.302–20.725 ng/mL for amlodipine and 6.062–18060.792 ng/mL for valsartan. The method has shown good reproducibility, as intra- and interday precisions were within 10% and accuracies were within 8% of nominal values for both analytes. The method was successfully applied for the bioequivalence study of amlodipine and valsartan after oral administration of a fixed dose of the combination. Additionally, as required by the current regulatory bodies, incurred sample reanalysis was performed and found to be acceptable

    Rapid sensitive validated UPLCâMS method for determination of venlafaxine and its metabolite in rat plasma: Application to pharmacokinetic study

    No full text
    A new ultra-performance liquid chromatographyâelectrospray ionization mass spectrometry (UPLCâMS/ESI) method for simultaneous determination of venlafaxine (VEN) and its metabolite O-desmethylvenlafaxine (ODV) in rat plasma has been developed and validated using Venlafaxine d6 as the internal standard. The compounds and internal standard were extracted from plasma by solid phase extraction. The UPLC separation of the analytes was performed on ACQUITY UPLC® BEH Shield RP18 (1.7 µm, 100 mmÃ2.1 mm) column, using isocratic elution with mobile phase constituted of water (containing 2 mM ammonium acetate): acetonitrile (20:80, v/v) at a flow rate of 0.3 mL/min. All of the analytes were eluted within 1.5 min. The compounds were ionized in the electrospray ionization (ESI) ion source of the mass spectrometer, operating in multiple reaction monitoring (MRM) and positive ion mode. The precursor to product ion transitions monitored for VEN, ODV and Venlafaxine d6 were m/z 278.3â121.08, 264.2â107.1 and 284.4â121.0, respectively. The developed and validated method was used for the pharmacokinetic study of VEN in rats. Keywords: Venlafaxine, O-desmethylvenlafaxine, Metabolite, UPLCâMS/E

    New chiral reverse phase HPLC method for enantioselective analysis of ketorolac using chiral AGP column

    Get PDF
    A simple, specific, precise, sensitive and rapid reverse phase-HPLC method was developed for determination of ketorolac enantiomers, a potent nonnarcotic analgesic in pharmaceutical formulations. The method was developed on a chiral AGP column. Mobile phase was 0.1 M sodium phosphate buffer (pH 4.5): Isopropanol (98:2, v/v), at a flow rate of 1 mL/min with run time of 15 min. Ultraviolet detection was made at 322 nm. The linearity range was 0.02â10 μg/mL for each of the enantiomers. The mobile phase composition was systematically studied to find the optimum chromatographic conditions. Validation of the method under the conditions selected showed that it was selective and precise and that the detector response was linear function of ketorolac. Keywords: R-Ketorolac, S-Ketorolac, Chiral AGP, RP-HPL