847 research outputs found

    Observation of narrow fluorescence from doubly driven four-level atoms at room temperature

    Full text link
    Unusually narrow fluorescence peaks are seen from Rubidium-85 atoms under the action of two driving laser fields that are in a three dimensional molasses configuration. One of the lasers is held at a fixed detuning from the "cooling" transition, while the other is scanned across the "repumping" transitions. The fluorescence peaks are split into symmetric pairs, with the seperation within a pair increasing with the detuning of the cooling laser. For large detunings additional small peaks are seen. A simple model is proposed to explain these experimental observations.Comment: 8 pages, 4 figures, needs epl.cl

    PREDICTING RATINGS FOR USER REVIEWS AND OPINION MINING ANALYZE FOR PHYSICIANS AND HOSPITALS

    Get PDF
    ABSTRACTHealth care is taking its turn in the internet now and online health information consumption is also booming. Users have started generating healthcarereports like online doctor reviews open to all. Hence, online health forums are increasingly popular these days since people can gather their requireddata by just sitting at home and select the best doctor by considering the reviews available online. The patients also browse on their concerneddiseases and use the open forum for discussion on the topics. On an average, these online health-care providers are mainly focusing on reviews aboutthe physicians. The feedback provided by patients is considered and we also analyze the sentiments of the patient to estimate the value of the reviews.The rating for the doctors is divided into various categories such as Staff, Knowledge, and Helpfulness. We propose support vector machine and apriorifor the classification of data and use sentiment based rating prediction to analyze doctor's reviews and opinion mining patterns for online patterns.By providing physician ratings in website, it offers the patients to know about the physician and consider the critique and information to make theirdecision.Keywords: Support vector machine, Apriori, Sentiment classification, Opinion mining

    Algorithm for Suppression of Wideband Probing in Adaptive Array with Multiple Desired Signals

    Get PDF
    The integrity of signal environment for a navigation system among other factors depends critically on the capability of the adaptive antenna array in controlling (reconfiguring) its radiation pattern for various signal scenarios. For a signal environment consisting of simultaneous multiple desired signals and probing sources, the output signal-to-noise ratio of the adaptive antenna array depends on the efficiency of the adaptive algorithm employed for weight estimation. Sufficient antenna gain is required to be maintained towards each of the desired signals, while simultaneously suppressing returns towards the sources probing from distinctly different directions. The weight estimation for the multiple desired signal environments is carried out using a novel modified version of the improved least mean square (LMS) algorithm. This modified scheme effectively suppresses the narrowband/wideband probing towards the antenna array (linear/planar). The weight estimation and the steering vector are adapted according to the multiple desired signal environments. Each spectral line of the wideband source is considered as an independent narrowband source. This is incorporated in the correlation matrix of the received signal. The simulation results demonstrate the efficacy of this novel algorithm in active cancellation of narrowband/wideband probing sources, even while the simultaneous multiple signals in desired directions are maintained. The performance of the proposed algorithm is reported to be better than that of standard LMS and recursive LMS algorithm.Defence Science Journal, 2011, 61(4), pp.325-330, DOI:http://dx.doi.org/10.14429/dsj.61.109

    Low sidelobe level microstrip patch array: Em design and performance analysis

    Get PDF
    A high performance low-profile antenna array with low sidelobe level (SLL) and optimum beamwidth is in general preferred in several communication related applications. In this paper a planar microstrip array antenna with low SLL up to -20 dB and high gain performance is designed for 10 GHz. The dimensions of patch antenna is tapered to achieve low SLL. The results for patch array with individual feed and a common feed are presented

    Evaluation of role of laparoscopy in determining etiology of infertility

    Get PDF
    Background: Although population explosion is a major problem in India, infertility appears to be a problem in 5-15% of Indian population. All these patients require evaluation. Laparoscopy plays a valuable role in the diagnosis of infertility. After thorough clinical examination and specific investigations, diagnostic laparoscopy is performed to detect patency of tubes, morphological defects in uterus, ovaries and tuboperitoineal factors. This study was conducted to assess the role of diagnostic laparoscopy in the investigation of female infertility and to evaluate the various causes of infertility like endometriosis, PCOD tubal and peritoneal factors, uterine anomalies, tuberculosis etc. by using diagnostic laparoscopy.Methods: Study was carried out in 60 infertile patients attending outpatient department of hospitals attached to Sri Siddhartha Medical College Hospital, Tumkur.  Both primary and secondary infertility patients who were anxious to conceive and undergo diagnostic laparoscopy were evaluated. Those who were not willing and who were contraindicated for the procedure were excluded.Results: Diagnostic laparoscopy was performed in 72% of primary and 28% of secondary infertility patients. Majority of the patients of primary infertility were in age group 21-25 years and that of secondary were between 26-30 years. Majority of patients in both the groups had duration of 1-5 year of infertility. In our study tubal factors (50%) contributed to majority of the infertility causes. Complication rate was minimum and was comparable to other standard studies.Conclusions: Laparoscopic is the gold standard for diagnosing tubal and peritoneal disease, endometriosis and other pelvic pathology, because no other imaging technique gives the same degree of sensitivity or specificity. Hence diagnostic laparoscopy is an indispensable tool in the evaluation in the evaluation infertility

    Obstetric outcome study of oligohydramnios beyond 34 completed weeks of gestation

    Get PDF
    Background: Perinatal morbidity and mortality are significantly increased when oligohydramnios is present. As the amniotic fluid volume decreases, the perinatal mortality rate increases. The incidence of major congenital anomalies with IUGR also increases as the amniotic fluid volume declines. There is a close association between declining placental function in the latter part of the third trimester and amniotic fluid volume1. Thus, post term patients are at a greater risk for development of oligohydramnios. Fetal anomalies that results in oligohydramnios classically involve the urinary tract. The most frequently mentioned renal anomalies include bilateral renal agenesis, multicystic dysplastic kidneys, bladder outlet obstruction and infantile polycystic kidneys.Methods: All antenatal patients seen in the Department of Obstetrics and Gynecology at Sri Siddhartha Medical College and Research Centre between January 2015 to January 2017, who were willing to participate in the trial study were enrolled. Ultrasound GE Voulson S8-PRO equipped with 3.5 MHz transducer was used to measure the amniotic fluid index. The AFI in each group was noted and the pregnancy outcome in each group was determined. At the time of delivery following data variables were collected and compiled.Results: There were 105 women, who were divided into three groups of 35 each. Those women with AFI<5 had more chances of emergency caesarian section, the causes were fetal distress with variable and late fetal heart decelerations. The incidence of meconium stained liquor and NICU admission were more.Conclusions: The women with AFI<5 had more chances of emergency caesarian section, the causes were fetal distress with variable and late fetal heart decelerations. Amniotic Fluid Index is a valuable screening test for detecting fetuses that may have poor perinatal outcome
    corecore