3 research outputs found

    Effect of Denture Base Fabrication Technique on Candida albicans Adhesion In Vitro

    No full text
    Denture stomatitis is a common manifestation of oral candidiasis affecting some 65% of denture wearers. This condition is initiated by the adherence of Candida albicans to denture base acrylic resin. The present study aimed to test the in vitro effect of traditional and novel fabrication methods on Candida albicans adhesion to denture base samples. Denture based acrylic discs were fabricated using: (i) computerized milling, (ii) 3D printing, (iii) heat curing, and (iv) cold curing. Discs were tested for surface roughness (Ra), hydrophobicity (contact angle), mucin adsorption (Bradford assay), and Candida albicans adhesion. 3D printing significantly increased microbial cell adhesion as compared with heat curing, and computerized milling significantly decreased it. These results were associated with mucin adsorption levels rather than surface roughness. Results suggest that 3D printing may increase the risk for developing denture stomatitis, whereas computerized milling may decrease it as compared with traditional heat curing denture base fabrication

    Influence of Vinyl Polysiloxane Impression Techniques on Marginal Fit of Metal Frameworks for Fixed Partial Dentures

    No full text
    Impression technique is one of the factors affecting restoration fit accuracy, which is a major aspect influencing its survival. The purpose of this study is to compare, in vivo, the effect of two commonly used Vinyl Polysiloxane (VPS) impression techniques on the metal framework fitting of fixed partial dentures. Ninety-two consecutive patients, diagnosed as partially edentulous, treated by fixed partial denture restorations, participated in the study. Group 1-impressions (n = 44) were subjected to the 1-step technique, while group 2 impressions (n = 48) were subjected the 2-step technique. Three accuracy assessment common methods: probe, tactile sense and radiographic test, were used to validate the clinical fit of the metal framework. Misfit was defined as even one test failure. Twenty-one (22.8%) out of 92 metal frameworks exhibited metal frameworks misfit, whereas the other 71 (77.2%) were found to be accurate. Group 1 presented significantly (p = 0.04) more metal frameworks misfit, 14/44 (31.8%) vs. 7/48 (14.6%). Restoration location (maxilla vs. mandible) had no statistically significant impact on the results (p = 0.461). The use of the VPS putty/wash 2-step impression technique is recommended to improve the clinical fit of fixed partial denture restorations

    The Influence of Laboratory Scanner Versus Intra-Oral Scanner on Determining the Implant Axis by Using Three Different Scan Abutments

    No full text
    Background: The purpose of this in vitro study was to compare the implant axis’ spatial position and orientation by using laboratory scanner versus intra-oral scanner with three different scan abutments. Methods: A 3D model was printed with an internal hex implant analog in the place of teeth 35#. Three standard scan abutments were used: MIS (two-piece titanium), AB (two-piece PEEK and titanium base) and ZZ (one-piece PEEK). Each scan abutment was scanned 30 times by TRIOS E3 (laboratory scanner) and 30 times by Omnicam (intra-oral scanner). For each scan, an STL (stereolithography) file was created, and the spatial characterization of each scan abutment was measured in the X, Y, Z coordinates, and rotational and longitudinal angles. The comparison between all the scans was conducted by superimposition of the STL files, using a 3D software. A t-test and Wilcoxon signed-rank test were used. (p < 0.05) Results: Only the MIS scan abutment showed no statistical difference in the X and Z axes. (p < 0.05). All other scan abutments showed a statistical difference in all axes. The rotational angle of the AB scan abutment was twice the angle of the MIS and ZZ scan abutments. Conclusions: All three scan abutments showed a rotational deviation of the implant axis between the laboratory scanner and the intra-oral scanner. The AB scan abutment showed the greatest deviation (1.04 degrees) while the other two abutments showed deviations of about half a degree in relation to the laboratory scan abutment. There is a need for further studies which will examine the influence of geometry, material, and scan abutment parts on the accuracy of the scan obtained
    corecore