48 research outputs found

    Effect of Nuclear Stiffness on Cell Mechanics and Migration of Human Breast Cancer Cells

    Get PDF
    The migration and invasion of cancer cells through 3D confined extracellular matrices is coupled to cell mechanics and the mechanics of the extracellular matrix. Cell mechanics is mainly determined by both the mechanics of the largest organelle in the cell, the nucleus, and the cytoskeletal architecture of the cell. Hence, cytoskeletal and nuclear mechanics are the major contributors to cell mechanics. Among other factors, steric hindrances of the extracellular matrix confinement are supposed to affect nuclear mechanics and thus also influence cell mechanics. Therefore, we propose that the percentage of invasive cells and their invasion depths into loose and dense 3D extracellular matrices is regulated by both nuclear and cytoskeletal mechanics. In order to investigate the effect of both nuclear and cytoskeletal mechanics on the overall cell mechanics, we firstly altered nuclear mechanics by the chromatin de-condensing reagent Trichostatin A (TSA) and secondly altered cytoskeletal mechanics by addition of actin polymerization inhibitor Latrunculin A and the myosin inhibitor Blebbistatin. In fact, we found that TSA-treated MDA-MB-231 human breast cancer cells increased their invasion depth in dense 3D extracellular matrices, whereas the invasion depths in loose matrices were decreased. Similarly, the invasion depths of TSA-treated MCF- 7 human breast cancer cells in dense matrices were significantly increased compared to loose matrices, where the invasion depths were decreased. These results are also valid in the presence of a matrix-metalloproteinase inhibitor GM6001. Using atomic force microscopy (AFM), we found that the nuclear stiffnesses of both MDA-MB- 231 and MCF-7 breast cancer cells were pronouncedly higher than their cytoskeletal stiffness, whereas the stiffness of the nucleus of human mammary epithelial cells was decreased compared to their cytoskeleton. TSA treatment reduced cytoskeletal and nuclear stiffness of MCF-7 cells, as expected. However, a softening of the nucleus by TSA treatment may induce a stiffening of the cytoskeleton of MDA-MB-231 cells and subsequently an apparent stiffening of the nucleus. Inhibiting actin polymerization using Latrunculin A revealed a softer nucleus of MDA-MB-231 cells under TSA treatment. This indicates that the actin-dependent cytoskeletal stiffness seems to be influenced by the TSA-induced nuclear stiffness changes. Finally, the combined treatment with TSA and Latrunculin A further justifies the hypothesis of apparent nuclear stiffening, indicating that cytoskeletal mechanics seem to be regulated by nuclear mechanics

    Inhomogeneities in 3D Collagen Matrices Impact Matrix Mechanics and Cancer Cell Migration

    Get PDF
    Cell motility under physiological and pathological conditions including malignant progression of cancer and subsequent metastasis are founded on environmental confinements. During the last two decades, three-dimensional cell migration has been studied mostly by utilizing biomimetic extracellular matrix models. In the majority of these studies, the in vitro collagen scaffolds are usually assumed to be homogenous, as they consist commonly of one specific type of collagen, such as collagen type I, isolated from one species. These collagen matrices should resemble in vivo extracellular matrix scaffolds physiologically, however, mechanical phenotype and functional reliability have been addressed poorly due to certain limitations based on the assumption of homogeneity. How local variations of extracellular matrix structure impact matrix mechanics and cell migration is largely unknown. Here, we hypothesize that local inhomogeneities alter cell movement due to alterations in matrix mechanics, as they frequently occur in in vivo tissue scaffolds and were even changed in diseased tissues. To analyze the effect of structural inhomogeneities on cell migration, we used a mixture of rat tail and bovine dermal collagen type I as well as pure rat and pure bovine collagens at four different concentrations to assess three-dimensional scaffold inhomogeneities. Collagen type I from rat self-assembled to elongated fibrils, whereas bovine collagen tended to build node-shaped inhomogeneous scaffolds. We have shown that the elastic modulus determined with atomic force microscopy in combination with pore size analysis using confocal laser scanning microscopy revealed distinct inhomogeneities within collagen matrices. We hypothesized that elastic modulus and pore size govern cancer cell invasion in three-dimensional collagen matrices. In fact, invasiveness of three breast cancer cell types is altered due to matrix-type and concentration indicating that these two factors are crucial for cellular invasiveness. Our findings revealed that local matrix scaffold inhomogeneity is another crucial parameter to explain differences in cell migration, which not solely depended on pore size and stiffness of the collagen matrices. With these three distinct biophysical parameters, characterizing structure and mechanics of the studied collagen matrices, we were able to explain differences in the invasion behavior of the studied cancer cell lines in dependence of the used collagen model

    A Beginner’s Guide to the Characterization of Hydrogel Microarchitecture for Cellular Applications

    Get PDF
    The extracellular matrix (ECM) is a three-dimensional, acellular scaffold of living tissues. Incorporating the ECM into cell culture models is a goal of cell biology studies and requires biocompatible materials that can mimic the ECM. Among such materials are hydrogels: polymeric networks that derive most of their mass from water. With the tuning of their properties, these polymer networks can resemble living tissues. The microarchitectural properties of hydrogels, such as porosity, pore size, fiber length, and surface topology can determine cell plasticity. The adequate characterization of these parameters requires reliable and reproducible methods. However, most methods were historically standardized using other biological specimens, such as 2D cell cultures, biopsies, or even animal models. Therefore, their translation comes with technical limitations when applied to hydrogel-based cell culture systems. In our current work, we have reviewed the most common techniques employed in the characterization of hydrogel microarchitectures. Our review provides a concise description of the underlying principles of each method and summarizes the collective data obtained from cell-free and cell-loaded hydrogels. The advantages and limitations of each technique are discussed, and comparisons are made. The information presented in our current work will be of interest to researchers who employ hydrogels as platforms for cell culture, 3D bioprinting, and other fields within hydrogel-based research

    Systematic review and cumulative analysis of perioperative outcomes and complications after robot-assisted radical cystectomy

    Get PDF
    CONTEXT: Although open radical cystectomy (ORC) is still the standard approach, laparoscopic radical cystectomy (LRC) and robot-assisted radical cystectomy (RARC) have gained popularity. OBJECTIVE: To report a systematic literature review and cumulative analysis of perioperative outcomes and complications of RARC in comparison with ORC and LRC. EVIDENCE ACQUISITION: Medline, Scopus, and Web of Science databases were searched using a free-text protocol including the terms robot-assisted radical cystectomy or da Vinci radical cystectomy or robot* radical cystectomy. RARC case series and studies comparing RARC with either ORC or LRC were collected. Cumulative analysis was conducted. EVIDENCE SYNTHESIS: The searches retrieved 105 papers. According to the different diversion type, overall mean operative time ranged from 360 to 420 min. Similarly, mean blood loss ranged from 260 to 480 ml. Mean in-hospital stay was about 9 d for all diversion types, with consistently high readmission rates. In series reporting on RARC with either extracorporeal or intracorporeal conduit diversion, overall 90-d complication rates were 59% (high-grade complication: 15%). In series reporting RARC with intracorporeal continent diversion, the overall 30-d complication rate was 45.7% (high-grade complication: 28%). Reported mortality rates were ≤3% for all diversion types. Comparing RARC and ORC, cumulative analyses demonstrated shorter operative time for ORC, whereas blood loss and in-hospital stay were better with RARC (all p values <0.003). Moreover, 90-d complication rates of any-grade and 90-d grade 3 complication rates were lower for RARC (all p values <0.04), whereas high-grade complication and mortality rates were similar. CONCLUSIONS: RARC can be performed safely with acceptable perioperative outcome, although complications are common. Cumulative analyses demonstrated that operative time was shorter with ORC, whereas RARC may provide some advantages in terms of blood loss and transfusion rates and, more limitedly, for postoperative complication rates over ORC and LRC. PATIENT SUMMARY: Although open radical cystectomy (RC) is still regarded as a standard treatment for muscle-invasive bladder cancer, laparoscopic and robot-assisted RC are becoming more popular. Robotic RC can be safely performed with acceptably low risk of blood loss, transfusion, and intraoperative complications; however, as for open RC, the risk of postoperative complications is high, including a substantial risk of major complication and reoperation

    Environmentally controlled magnetic nano-tweezer for living cells and extracellular matrices

    Get PDF
    The magnetic tweezer technique has become a versatile tool for unfolding or folding of individual molecules, mainly DNA. In addition to single molecule analysis, the magnetic tweezer can be used to analyze the mechanical properties of cells and extracellular matrices. We have established a magnetic tweezer that is capable of measuring the linear and non-linear viscoelastic behavior of a wide range of soft matter in precisely controlled environmental conditions, such as temperature, CO2 and humidity. The magnetic tweezer presented in this study is suitable to detect specific differences in the mechanical properties of different cell lines, such as human breast cancer cells and mouse embryonic fibroblasts, as well as collagen matrices of distinct concentrations in the presence and absence of fibronectin crosslinks. The precise calibration and control mechanism employed in the presented magnetic tweezer setup provides the ability to apply physiological force up to 5 nN on 4.5 µm superparamagnetic beads coated with fibronectin and coupled to the cells or collagen matrices. These measurements reveal specific local linear and non-linear viscoelastic behavior of the investigated samples. The viscoelastic response of cells and collagen matrices to the force application is best described by a weak power law behavior. Our results demonstrate that the stress stiffening response and the fluidization of cells is cell type specific and varies largely between differently invasive and aggressive cancer cells. Finally, we showed that the viscoelastic behavior of collagen matrices with and without fibronectin crosslinks measured by the magnetic tweezer can be related to the microstructure of these matrices
    corecore