48 research outputs found
Effect of Nuclear Stiffness on Cell Mechanics and Migration of Human Breast Cancer Cells
The migration and invasion of cancer cells through 3D confined extracellular matrices
is coupled to cell mechanics and the mechanics of the extracellular matrix. Cell
mechanics is mainly determined by both the mechanics of the largest organelle in
the cell, the nucleus, and the cytoskeletal architecture of the cell. Hence, cytoskeletal
and nuclear mechanics are the major contributors to cell mechanics. Among other
factors, steric hindrances of the extracellular matrix confinement are supposed to affect
nuclear mechanics and thus also influence cell mechanics. Therefore, we propose that
the percentage of invasive cells and their invasion depths into loose and dense 3D
extracellular matrices is regulated by both nuclear and cytoskeletal mechanics. In order
to investigate the effect of both nuclear and cytoskeletal mechanics on the overall
cell mechanics, we firstly altered nuclear mechanics by the chromatin de-condensing
reagent Trichostatin A (TSA) and secondly altered cytoskeletal mechanics by addition
of actin polymerization inhibitor Latrunculin A and the myosin inhibitor Blebbistatin. In
fact, we found that TSA-treated MDA-MB-231 human breast cancer cells increased
their invasion depth in dense 3D extracellular matrices, whereas the invasion depths
in loose matrices were decreased. Similarly, the invasion depths of TSA-treated MCF-
7 human breast cancer cells in dense matrices were significantly increased compared
to loose matrices, where the invasion depths were decreased. These results are also
valid in the presence of a matrix-metalloproteinase inhibitor GM6001. Using atomic
force microscopy (AFM), we found that the nuclear stiffnesses of both MDA-MB-
231 and MCF-7 breast cancer cells were pronouncedly higher than their cytoskeletal
stiffness, whereas the stiffness of the nucleus of human mammary epithelial cells was
decreased compared to their cytoskeleton. TSA treatment reduced cytoskeletal and
nuclear stiffness of MCF-7 cells, as expected. However, a softening of the nucleus by
TSA treatment may induce a stiffening of the cytoskeleton of MDA-MB-231 cells and
subsequently an apparent stiffening of the nucleus. Inhibiting actin polymerization using
Latrunculin A revealed a softer nucleus of MDA-MB-231 cells under TSA treatment. This
indicates that the actin-dependent cytoskeletal stiffness seems to be influenced by the
TSA-induced nuclear stiffness changes. Finally, the combined treatment with TSA and
Latrunculin A further justifies the hypothesis of apparent nuclear stiffening, indicating that
cytoskeletal mechanics seem to be regulated by nuclear mechanics
Inhomogeneities in 3D Collagen Matrices Impact Matrix Mechanics and Cancer Cell Migration
Cell motility under physiological and pathological conditions including malignant
progression of cancer and subsequent metastasis are founded on environmental
confinements. During the last two decades, three-dimensional cell migration has been
studied mostly by utilizing biomimetic extracellular matrix models. In the majority of
these studies, the in vitro collagen scaffolds are usually assumed to be homogenous,
as they consist commonly of one specific type of collagen, such as collagen type I,
isolated from one species. These collagen matrices should resemble in vivo extracellular
matrix scaffolds physiologically, however, mechanical phenotype and functional reliability
have been addressed poorly due to certain limitations based on the assumption
of homogeneity. How local variations of extracellular matrix structure impact matrix
mechanics and cell migration is largely unknown. Here, we hypothesize that local
inhomogeneities alter cell movement due to alterations in matrix mechanics, as they
frequently occur in in vivo tissue scaffolds and were even changed in diseased tissues.
To analyze the effect of structural inhomogeneities on cell migration, we used a mixture
of rat tail and bovine dermal collagen type I as well as pure rat and pure bovine collagens
at four different concentrations to assess three-dimensional scaffold inhomogeneities.
Collagen type I from rat self-assembled to elongated fibrils, whereas bovine collagen
tended to build node-shaped inhomogeneous scaffolds. We have shown that the
elastic modulus determined with atomic force microscopy in combination with pore size
analysis using confocal laser scanning microscopy revealed distinct inhomogeneities
within collagen matrices. We hypothesized that elastic modulus and pore size govern
cancer cell invasion in three-dimensional collagen matrices. In fact, invasiveness of three
breast cancer cell types is altered due to matrix-type and concentration indicating that
these two factors are crucial for cellular invasiveness. Our findings revealed that local
matrix scaffold inhomogeneity is another crucial parameter to explain differences in
cell migration, which not solely depended on pore size and stiffness of the collagen
matrices. With these three distinct biophysical parameters, characterizing structure
and mechanics of the studied collagen matrices, we were able to explain differences
in the invasion behavior of the studied cancer cell lines in dependence of the used
collagen model
Recommended from our members
Structural Breakdown of Collagen Type I Elastin Blend Polymerization
Biopolymer blends are advantageous materials with novel properties that may show performances way beyond their individual constituents. Collagen elastin hybrid gels are a new representative of such materials as they employ elastin’s thermo switching behavior in the physiological temperature regime. Although recent studies highlight the potential applications of such systems, little is known about the interaction of collagen and elastin fibers during polymerization. In fact, the final network structure is predetermined in the early and mostly arbitrary association of the fibers. We investigated type I collagen polymerized with bovine neck ligament elastin with up to 33.3 weight percent elastin and showed, by using a plate reader, zeta potential and laser scanning microscopy (LSM) experiments, that elastin fibers bind in a lateral manner to collagen fibers. Our plate reader experiments revealed an elastin concentration-dependent increase in the polymerization rate, although the rate increase was greatest at intermediate elastin concentrations. As elastin does not significantly change the structural metrics pore size, fiber thickness or 2D anisotropy of the final gel, we are confident to conclude that elastin is incorporated homogeneously into the collagen fibers
A Beginner’s Guide to the Characterization of Hydrogel Microarchitecture for Cellular Applications
The extracellular matrix (ECM) is a three-dimensional, acellular scaffold of living tissues. Incorporating the ECM into cell culture models is a goal of cell biology studies and requires biocompatible materials that can mimic the ECM. Among such materials are hydrogels: polymeric networks that derive most of their mass from water. With the tuning of their properties, these polymer networks can resemble living tissues. The microarchitectural properties of hydrogels, such as porosity, pore size, fiber length, and surface topology can determine cell plasticity. The adequate characterization of these parameters requires reliable and reproducible methods. However, most methods were historically standardized using other biological specimens, such as 2D cell cultures, biopsies, or even animal models. Therefore, their translation comes with technical limitations when applied to hydrogel-based cell culture systems. In our current work, we have reviewed the most common techniques employed in the characterization of hydrogel microarchitectures. Our review provides a concise description of the underlying principles of each method and summarizes the collective data obtained from cell-free and cell-loaded hydrogels. The advantages and limitations of each technique are discussed, and comparisons are made. The information presented in our current work will be of interest to researchers who employ hydrogels as platforms for cell culture, 3D bioprinting, and other fields within hydrogel-based research
Systematic review and cumulative analysis of perioperative outcomes and complications after robot-assisted radical cystectomy
CONTEXT: Although open radical cystectomy (ORC) is still the standard approach, laparoscopic radical cystectomy (LRC) and robot-assisted radical cystectomy (RARC) have gained popularity.
OBJECTIVE: To report a systematic literature review and cumulative analysis of perioperative outcomes and complications of RARC in comparison with ORC and LRC.
EVIDENCE ACQUISITION: Medline, Scopus, and Web of Science databases were searched using a free-text protocol including the terms robot-assisted radical cystectomy or da Vinci radical cystectomy or robot* radical cystectomy. RARC case series and studies comparing RARC with either ORC or LRC were collected. Cumulative analysis was conducted.
EVIDENCE SYNTHESIS: The searches retrieved 105 papers. According to the different diversion type, overall mean operative time ranged from 360 to 420 min. Similarly, mean blood loss ranged from 260 to 480 ml. Mean in-hospital stay was about 9 d for all diversion types, with consistently high readmission rates. In series reporting on RARC with either extracorporeal or intracorporeal conduit diversion, overall 90-d complication rates were 59% (high-grade complication: 15%). In series reporting RARC with intracorporeal continent diversion, the overall 30-d complication rate was 45.7% (high-grade complication: 28%). Reported mortality rates were ≤3% for all diversion types. Comparing RARC and ORC, cumulative analyses demonstrated shorter operative time for ORC, whereas blood loss and in-hospital stay were better with RARC (all p values <0.003). Moreover, 90-d complication rates of any-grade and 90-d grade 3 complication rates were lower for RARC (all p values <0.04), whereas high-grade complication and mortality rates were similar.
CONCLUSIONS: RARC can be performed safely with acceptable perioperative outcome, although complications are common. Cumulative analyses demonstrated that operative time was shorter with ORC, whereas RARC may provide some advantages in terms of blood loss and transfusion rates and, more limitedly, for postoperative complication rates over ORC and LRC.
PATIENT SUMMARY: Although open radical cystectomy (RC) is still regarded as a standard treatment for muscle-invasive bladder cancer, laparoscopic and robot-assisted RC are becoming more popular. Robotic RC can be safely performed with acceptably low risk of blood loss, transfusion, and intraoperative complications; however, as for open RC, the risk of postoperative complications is high, including a substantial risk of major complication and reoperation
Environmentally controlled magnetic nano-tweezer for living cells and extracellular matrices
The magnetic tweezer technique has become a versatile tool for unfolding or folding of individual molecules, mainly DNA. In addition to single molecule analysis, the magnetic tweezer can be used to analyze the mechanical properties of cells and extracellular matrices. We have established a magnetic tweezer that is capable of measuring the linear and non-linear viscoelastic behavior of a wide range of soft matter in precisely controlled environmental conditions, such as temperature, CO2 and humidity. The magnetic tweezer presented in this study is suitable to detect specific differences in the mechanical properties of different cell lines, such as human breast cancer cells and mouse embryonic fibroblasts, as well as collagen matrices of distinct concentrations in the presence and absence of fibronectin crosslinks. The precise calibration and control mechanism employed in the presented magnetic tweezer setup provides the ability to apply physiological force up to 5 nN on 4.5 µm superparamagnetic beads coated with fibronectin and coupled to the cells or collagen matrices. These measurements reveal specific local linear and non-linear viscoelastic behavior of the investigated samples. The viscoelastic response of cells and collagen matrices to the force application is best described by a weak power law behavior. Our results demonstrate that the stress stiffening response and the fluidization of cells is cell type specific and varies largely between differently invasive and aggressive cancer cells. Finally, we showed that the viscoelastic behavior of collagen matrices with and without fibronectin crosslinks measured by the magnetic tweezer can be related to the microstructure of these matrices