95 research outputs found

    Improved Phase Modulation for an En-face Scanning Three-dimensional Optical Coherence Microscope

    Get PDF
    We have previously described an inexpensive method for modulating the interferometer of an en-face scanning, focus-tracking, three-dimensional optical coherence microscope (OCM). In this OCM design, a reference mirror is mounted on a piezoelectric stack driven at a resonance frequency of about 100 kHz. We perform a partial discrete Fourier transform of the digitally sampled output fringe signal. In the original design, we obtained the amplitude of the backscattered light by summing the powers in the fundamental (1ω) and first harmonic (2ω) of the modulation frequency. We used the particular piezoamplitude that eliminates the effects of interferometer phase drift. However, as the reference mirror was stepped to scan at different sample depths, variations in the back-coupled reference power added noise to the fringe signal at the fundamental piezodriving frequency. We report here a technique to eliminate the effects of this piezowobble by using instead the sum of the 2ω and 3ω powers as a measure of the backscattered light intensity. Images acquired before and after this improvement are presented to illustrate the enhancement to image quality deep within the sample

    An optical coherence microscope for 3-dimensional imaging in developmental biology

    Get PDF
    An optical coherence microscope (OCM) has been designed and constructed to acquire 3-dimensional images of highly scattering biological tissue. Volume-rendering software is used to enhance 3-D visualization of the data sets. Lateral resolution of the OCM is 5 mm (FWHM), and the depth resolution is 10 mm (FWHM) in tissue. The design trade-offs for a 3-D OCM are discussed, and the fundamental photon noise limitation is measured and compared with theory. A rotating 3-D image of a frog embryo is presented to illustrate the capabilities of the instrument

    Limits to Performance Improvement Provided by Balanced Interferometers and Balanced Detection in OCT/OCM Instruments

    Get PDF
    We compare the dynamic range of OCT/OCM instruments configured with unbalanced interferometers, e.g., Michelson interferometers, with that of instruments utilizing balanced interferometers and balanced photodetection. We define the dynamic range (DR) as the ratio of the maximum fringe amplitude achieved with a highly reflecting surface to the root-mean-square (rms) noise. Balanced systems achieve a dynamic range 2.5 times higher than that of a Michelson interferometer, enabling an image acquisition speed roughly 6 times faster. This maximum improvement occurs at light source powers of a few milliwatts. At light source powers higher than 30 mW, the advantage in acquisition speed of balanced systems is reduced to a factor of 4. For video-rate imaging, the increased cost and complexity of a balanced system may be outweighed by the factor of 4 to 6 enhancement in image acquisition speed. We include in our analysis the beat-noise resulting from incoherent fight backscattered from the sample, which reduces the advantage of balanced systems. We attempt to resolve confusion surrounding the origin and magnitude of beat-noise , first described by L. Mandel in 1962. Beat-noise is present in both balanced and unbalanced OCT/OCM instruments

    Phase Modulation at 125 kHz in a Michelson Interferometer Using an Inexpensive Piezoelectric Stack Driven at Resonance

    Get PDF
    Fast phase modulation has been achieved in a Michelson interferometer by attaching a lightweight reference mirror to a piezoelectric stack and driving the stack at a resonance frequency of about 125 kHz. The electrical behavior of the piezo stack and the mechanical properties of the piezo-mirror arrangement are described. A displacement amplitude at resonance of about 350 nm was achieved using a standard function generator. Phase drift in the interferometer and piezo wobble were readily circumvented. This approach to phase modulation is less expensive by a factor of roughly 50 than one based on an electro-optic effect

    Role of Beat Noise in Limiting the Sensitivity of Optical Coherence Tomography

    Get PDF
    The sensitivity and dynamic range of optical coherence tomography (OCT) are calculated for instruments utilizing two common interferometer configurations and detection schemes. Previous researchers recognized that the performance of dual-balanced OCT instruments is severely limited by beat noise, which is generated by incoherent light backscattered from the sample. However, beat noise has been ignored in previous calculations of Michelson OCT performance. Our measurements of instrument noise confirm the presence of beat noise even in a simple Michelson interferometer configuration with a single photodetector. Including this noise, we calculate the dynamic range as a function of OCT light source power, and find that instruments employing balanced interferometers and balanced detectors can achieve a sensitivity up to six times greater than those based on a simple Michelson interferometer, thereby boosting image acquisition speed by the same factor for equal image quality. However, this advantage of balanced systems is degraded for source powers greater than a few milliwatts. We trace the concept of beat noise back to an earlier paper [J. Opt. Soc. Am. 52, 1335 (1962)]

    Using Ripple Effects Maps to Identify Story Threads: A Framework to Link Private to Public Value

    Get PDF
    Extension professionals must demonstrate organizational value to garner public awareness and support. Measuring and communicating outcomes that have public value can be challenging. In this study, Ripple Effects Mapping incorporating the Community Capitals Framework was used to evaluate a childhood obesity prevention study, iCook 4-H, of youth-adult pairs in Maine. The objective was to describe the process of generating impact statements through story threads about program benefits to the participants and the potential benefits to nonparticipants, such as family members, friends, and other community members. Extension professionals can use storylines, or story threads, as a qualitative research technique to generate stories about private and public value from participants’ actions, experiences, and emotions following community programs. The story threads process can be used across disciplines to leverage community program data into public value messaging

    Associations of resting heart rate with concentrations of lipoprotein subfractions in sedentary men

    Get PDF
    In major prospective studies it has been reported that high heart rate at rest predicts the development of coronary heart disease (CHD) or cardiovascular disease (CVD) in men, but the mechanisms producing these relationships are unknown. Since lipoprotein levels contribute strongly to the risk of CHD and CVD, we examined the relationship of resting heart rate to plasma concentrations of high-density (HDL), low-density (LDL), and very low-density (VLDL) lipoproteins, apolipoprotein (apo) A-I and A-II, and serum concentrations of lipoprotein subfractions in 81 men to determine if atherogenic lipoproteins could potentially induce the reported association of heart rate with development of CHD or CVD. The significant (p less than or equal to .05) Spearman\u27s correlations for resting heart rate vs HDL2 mass (rs = - .24), HDL3 mass (rs = - .40), HDL cholesterol (rs = - .36), apo A-I (rs = - .29), triglycerides (rs = .31), VLDL cholesterol (rs = .24), VLDL mass (rs = .27), and LDL mass of Sof 0-7 subfraction (rs = .30) lend support to our hypothesis of lipoprotein-induced relationships of CHD with heart rate. The correlations of resting heart rate vs triglycerides, HDL cholesterol, HDL3 mass, VLDL mass, and LDL mass of Sof 0-7 subfraction remain significant when adjusted for adiposity, age, smoking habits, diet, and physical fitness as measured by maximum aerobic power (VO2 max) or submaximal heart rate during a graded exercise test

    Motion-Sensitive 3-D Optical Coherence Microscope Operating at 1300 nm for the Visualization of Early Frog Development

    Get PDF
    We present 3-dimensional volume-rendered in vivo images of developing embryos of the African clawed frog Xenopus laevis taken with our new en-face-scanning, focus-tracking OCM system at 1300 nm wavelength. Compared to our older instrument which operates at 850 nm, we measure a decrease in the attenuation coefficient by 33%, leading to a substantial improvement in depth penetration. Both instruments have motion-sensitivity capability. By evaluating the fast Fourier transform of the fringe signal, we can produce simultaneously images displaying the fringe amplitude of the backscattered light and images showing the random Brownian motion of the scatterers. We present time-lapse movies of frog gastrulation, an early event during vertebrate embryonic development in which cell movements result in the formation of three distinct layers that later give rise to the major organ systems. We show that the motion-sensitive images reveal features of the different tissue types that are not discernible in the fringe amplitude images. In particular, we observe strong diffusive motion in the vegetal (bottom) part of the frog embryo which we attribute to the Brownian motion of the yolk platelets in the endoderm
    • …
    corecore