6 research outputs found

    Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures

    Get PDF
    Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo

    Functional outcome of PFC Sigma fixed and rotating-platform total knee arthroplasty. A prospective randomised controlled trial

    No full text
    The aim of this study was to determine whether there is a difference in functional outcome between the PFC Sigma fixed-bearing and rotating-platform total knee replacement systems. One hundred twenty patients were randomised to receive either a fixed-bearing or rotating-platform PFC Sigma total knee replacement. Range of movement (ROM), Oxford knee score (OKS) and Knee Society score (KSS) were assessed independently before and one year after surgery. Weight-bearing X-rays were taken immediately and one year post surgery to determine the incidence of osteolysis and loosening. At a mean follow-up of 13.4 months there was no statistically significant difference in mean ROM, OKS and KSS between the two groups. There was no evidence of osteolysis or loosening in either of the groups and no revision for infection or implant failure. This study shows that there is no statistically significant difference in functional outcome between the two types of implants at short-term follow-up

    Femoral Neck Shortening After Hip Fracture Fixation Is Associated With Inferior Hip Function : Results From the FAITH Trial

    No full text

    Fixation using alternative implants for the treatment of hip fractures (FAITH): design and rationale for a multi-centre randomized trial comparing sliding hip screws and cancellous screws on revision surgery rates and quality of life in the treatment of femoral neck fractures

    No full text
    corecore