24 research outputs found

    Intrarater Reliability of Digital Thermography in Detecting Pin Site Infection:A Proof of Concept Study

    Get PDF
    AIM AND OBJECTIVE: The purpose of this study was to explore the capability and Intrarater reliability of thermography in detecting pin site infection. MATERIALS AND METHODS: This is an explorative proof of concept study. Clinical assessment of pin sites was performed by one examiner with the Modified Gordon Pin Infection Classification from grade 0 to 6. Thermography of the pin sites was performed with a FLIR C3 camera. The analysis of the thermographic images was done in the software FLIR Tools. The maximum skin temperature around the pin site and the maximum temperature for the whole thermographic picture were measured. An Intrarater agreement was established and test-retests were performed with different camera angles. RESULTS: Thirteen (four females, nine males) patients (age 9–72 years) were included. Indications for frames: Fracture (n=4), two deformity correction, one lengthening and six bone transport. Days from surgery to thermography ranged from 27 to 385 days. Overall, 231 pin sites were included. Eleven pin sites were diagnosed with early signs of infection: five grade 1, five grade 2 and one grade 3. Mean pin site temperature for each patient was calculated, varied between patients from 29.0°C to 35.4°C (mean 33.9°C). With 34°C as cut-off value for infection, sensitivity was 73%; specificity, 67%; positive predictive value, 10%; and negative predictive value, 98%. Intrarater agreement for thermography was ICC 0.85 (0.77–0.92). The temperature measured was influenced by the camera positioning in relation to the pin site with a variance of 0.2. CONCLUSIONS: Measurements of pin site temperature using the hand-held FLIR C3 infrared camera was a reliable method and the temperature was related to infection grading. CLINICAL SIGNIFICANCE: This study demonstrated that digital thermography with a hand-held camera might be used for monitoring the pin sites after operations to detect early infection. HOW TO CITE THIS ARTICLE: Rahbek O, Husum HC, Fridberg M, et al. Intrarater Reliability of Digital Thermography in Detecting Pin Site Infection: A Proof of Concept Study. Strategies Trauma Limb Reconstr 2021;16(1):1–7

    Self-reported knowledge of national guidelines for clinical screening for hip dysplasia:a web-based survey of midwives and GPs in Denmark

    Get PDF
    Background: The positive predictive value of clinical hip examinations performed by generalist health professionals in screening for developmental dysplasia of the hip (DDH) is low and declining. Aim: To assess the self-reported recognition of nationally recommended clinical hip examinations in the screening programme for DDH in Denmark among midwives, GPs, and GPs in training. Design & setting: A cross-sectional, web-based open survey study among Danish midwives, GPs, and GPs in training. Method: Responders were asked to identify which of six written statements of clinical hip examinations were featured in the national Danish guidelines on DDH screening. Three statements were the official statements of the Ortolani, Galeazzi, and hip abduction examinations from the national guidelines, and three statements were false and constructed by the author group. Participants were asked to select up to six statements. Results: A total of 178 (58 GPs, 97 midwives, and 23 GPs in training) responses were included. Overall, 89% of responders correctly identified the Ortolani manoeuvre and 92% correctly identified one of the constructed descriptions as being false. The remaining four descriptions had significantly lower correct answer percentages ranging from 41%–58%, with significantly lower correct answer percentages of midwives for three out of all six descriptions when compared with GPs. Conclusion: The recognition of two out of three recommended clinical hip examinations in the Danish screening programme for DDH is low overall among current screeners. Efforts should be made to heighten the knowledge level by further education of screeners

    Pubo-Femoral Distances Measured Reliably by Midwives in Hip Dysplasia Ultrasound

    Get PDF
    The pubo-femoral distance (PFD) has been suggested as an ultrasound screening tool for developmental dysplasia of the hip (DDH). The aim of this study was to examine if midwives undergoing minimal training could reliably perform pediatric hip ultrasound and PFD measurements. Eight recruited midwives performed two rounds of independent blinded PFD measurements on 15 static ultrasound images and participated in four supervised live-scanning sessions. The midwives were compared to a group of three experienced musculoskeletal radiologists. Reliability was evaluated using inter-rater correlation coefficients (ICC). Linear regression was used to quantify the learning curve of the midwives as a group. There was near complete intra- and inter-rater agreement (ICC > 0.89) on static ultrasound images across both rounds of rating for midwives and radiologists. The midwives performed a mean of 29 live hip scans (range 24–35). The mean difference between midwives and supervising radiologists was 0.36 mm, 95% CI (0.12–0.61) for the first session, which decreased to 0.20 mm, 95% CI (0.04–0.37) in the fourth session. ICC for PFD measurements increased from 0.59 mm, 95% CI (0.37–0.75) to 0.78 mm, 95% CI (0.66–0.86) with progression in sessions. We conclude that midwives reliably perform PFD measurements of pediatric hips with minimal training

    Birthweight correlates to pubo-femoral distances and α angles in hip ultrasound of newborns at 6 weeks of age: a retrospective cohort study

    Get PDF
    Background and purpose: There is inconsistency in the literature regarding the relationship between increased birthweight and risk of developmental dysplasia of the hip (DDH). We aimed to investigate the correlation between birthweight and pubo-femoral distance (PFD), as well as Graf's α angle in newborns undergoing hip ultrasound examination at 6 weeks of age.Patients and methods: Basic newborn characteristics and ultrasound measurements were retrospectively collected during a 1-year study period. We excluded multiple births, newborns born at less than 37 gestational weeks, and incomplete information. Simple and multiple linear regression analyses were performed to evaluate the correlation of birthweight and PFD, and, second, birthweight and α angles including a stratified regression analysis investigating the potential effect modification of sex.Results: 707 newborns (1,414 hips) were included. Mean birthweight was significantly higher for male newborns (P < 0.001). Increased birthweight was positively correlated to PFD values (crude coefficient 0.21, 95% confidence interval [CI] 0.10-0.32) and the correlation was still present after adjusting for sex, family history, and breech presentation (adjusted coefficient 0.18, CI 0.07-0.29). The stratified α angle model for the males was significant for both the crude coefficient (-0.73, CI -1.28 to -0.19) and the adjusted (-0.59, CI -1.15 to -0.03), and also for the females (crude coefficient -1.14, CI -1.98 to -0.31 and adjusted coefficient -1.15, CI -1.99 to -0.31).Conclusion: We found that increased birthweight positively correlated to PFD, and negatively correlated to α angle, but this was not of clinical significance

    Pubo-femoral distance measurements in screening for developmental dysplasia of the hip

    No full text

    Suggestion for new 4.4 mm pubo-femoral distance cut-off value for hip instability in lateral position during DDH screening

    No full text
    Background and purpose — Current selective screening algorithms for developmental dysplasia of the hip (DDH) are insufficient. Universal screening programs have been proposed but so far have been deemed too expensive and time consuming. The pubo-femoral distance may solve this problem as a quick, low-cost, highly sensitive, and specific sonographic measurement for DDH, but this has only been validated in the supine position. Therefore we validated pubo-femoral distance (PFD) in the lateral position as an indicator for instability of the hip. Methods — All participants had undergone ultrasonographic diagnostics using the modified Graf technique. In addition, PFD measurements in lateral position were performed. Results were compared between 25 infants who had been treated for DDH because of dysplastic appearance on ultrasound combined with clinical instability and a control group consisting of 100 untreated infants screened for DDH. Sensitivity, specificity, and cut-off points were determined using Receiver operating characteristics (ROC) analysis. Results — We found a mean PFD of 6.8 mm (6.2–7.4) in the treated group with a control group PFD of 3.4 mm (3.3–3.6) (p < 0.005). A PFD value above a threshold of 4.4 mm yielded a sensitivity of 100% and a specificity of 93% for detecting unstable DDH. Interpretation — PFD measured in lateral position was statistically significantly increased in hips of children treated for DDH with Denis Browne hip brace compared with healthy children with unaffected stable hips. Furthermore, the PFD measurement had a high level of sensitivity and specificity at a cut-off value of 4.4 mm. A cut-off value of 6.00 mm has previously been reported as the gold standard in supine position. We suggest that 4.4 mm is used in lateral position
    corecore