13 research outputs found

    Subjective Evaluation of Right Ventricular Systolic Function in Hypoplastic Left Heart Syndrome:How Accurate Is It?

    No full text
    BACKGROUND: The geometry and heterogeneity of the right ventricle in hypoplastic left heart syndrome makes objective echocardiographic assessment of systolic function challenging. Consequently, subjective echocardiographic assessment of right ventricular (RV) function is still routinely undertaken. The aims of this study were to compare this with magnetic resonance imaging (MRI), investigate the impact of experience and training on the accuracy of subjective assessment, and critically analyze the role of echocardiography to detect impaired systolic function. METHODS: A retrospective analysis of prospectively acquired data was performed. Children with hypoplastic left heart syndrome underwent routine preoperative cardiac MRI and echocardiography under the same general anesthetic. Echocardiograms were reviewed, and members of the congenital heart disease team with differing echocardiography experience subjectively graded RV systolic function (good, moderate, or poor). This was compared with MRI-derived ejection fraction. RESULTS: Twenty-eight patients at different palliative stages were included. Twenty-eight observers were divided into five experience categories (congenital heart disease junior trainees to attending cardiologists). Median agreement was 47.6% (range, 31.4%–58.2%), with the lowest agreement among junior trainees and the highest among attending cardiologists. When used as a screening test for poor RV systolic function, the median sensitivity of echocardiography was 0.89 (range, 0.86–0.96), and median specificity was 0.45 (range, 0.26–0.55). The highest sensitivity was observed among junior trainees but with the lowest specificity. The highest specificity was observed among attending cardiologists (0.55). CONCLUSIONS: Agreement between echocardiographic and MRI RV ejection fraction improves with experience but remains suboptimal. When used as a screening test for poor RV function, echocardiography is sensitive, but specificity is heavily influenced by operator experience

    Cardiovascular Magnetic Resonance catheterization derived pulmonary vascular resistance and medium-term outcomes in congenital heart disease

    Get PDF
    BACKGROUND: Selection of patients with congenital heart disease for surgical septation in biventricular repair or surgical palliation in functionally single ventricles requires low pulmonary vascular resistance (PVR). Where there is uncertainty, PVR can be assessed using hybrid cardiovascular magnetic resonance (CMR) and fluoroscopic (X-Ray) guided cardiac catheterizations (XMR). CMR/XMR catheterization is a validated technique for accurate assessment of pulmonary vascular resistance. However, data concerning its application in clinical practice is lacking. METHODS: PVR assessments were performed in 167 studies in 149 congenital heart disease patients by CMR/XMR catheterization. Data was collated on patient demographics, procedural data, complications and outcomes. Institutional ethics approval was obtained. RESULTS: Median age was 3.6 years (6 days - 67 years) and weight 13.8 kg (2.3 -122 kg). One hundred and eight studies were in biventricular circulations and 59 in functionally single ventricles. Median radiation dose was 0.72 mSv. A baseline Qp:Qs ≤2.75 in biventricular circulations with left-to-right shunts predicted a PVR ≥6 WU.m(2) with 100% sensitivity and 48% specificity. Median follow up until death or last review was 4.2 years (4 days - 11 years). Eighty-four patients had a surgical or catheter intervention based on CMR/XMR catheterization findings at a median of 94 days after the study. This included successful biventricular repair at resting PVR values ≤6 WU.m(2) and Fontan completion at ≤4 WU.m(2). CONCLUSION: PVR measured by CMR/XMR catheterization allows accurate stratification for intervention in patients with congenital heart disease in both, biventricular and univentricular circulations
    corecore