109 research outputs found

    A Rectangular Planar Spiral Antenna for GIS Partial Discharge Detection

    Get PDF
    A rectangular planar spiral antenna sensor was designed for detecting the partial discharge in gas insulation substations (GIS). It can expediently receive electromagnetic waves leaked from basin-type insulators and can effectively suppress low frequency electromagnetic interference from the surrounding environment. Certain effective techniques such as rectangular spiral structure, bow-tie loading, and back cavity structure optimization during the antenna design process can miniaturize antenna size and optimize voltage standing wave ratio (VSWR) characteristics. Model calculation and experimental data measured in the laboratory show that the antenna possesses a good radiating performance and a multiband property when working in the ultrahigh frequency (UHF) band. A comparative study between characteristics of the designed antenna and the existing quasi-TEM horn antenna was made. Based on the GIS defect simulation equipment in the laboratory, partial discharge signals were detected by the designed antenna, the available quasi-TEM horn antenna, and the microstrip patch antenna, and the measurement results were compared

    High-throughput dielectrophoretic cell sorting assisted by cell sliding on scalable electrode tracks made of conducting-PDMS

    Get PDF
    Dielectrophoresis (DEP) as a label-free cell separation approach in microdevices has been extensively investigated for a variety of applications. 3D microelectrodes made of conducting-PDMS inherit the merit of volumetric electrodes for generating influential DEP force throughout the entire channel depth and meanwhile, exploit low-cost fabrication process by soft lithography. However, the configuration of conducting-PDMS electrodes is limited to being embedded in sidewall of flow chamber, which leads to rather low flow rate and difficulties in extension of the flow rate. We previously reported a more effective configuration with 3D interdigitated electrodes made of silicon that assist cell sliding along solid tracks, yet such device requires expensive silicon dry etching and, moreover, the track appears to be patterned with non-straight and wavy outline, which not only hinders the flow rate but also allows cell sliding to occur only along its downstream side. Here we demonstrate low-cost silver-PDMS electrode-track featuring ideally straight outline that induces rather uniform drag to drive smooth cell sliding. Such design achieves live and dead cell separation at flow rate twice as that of silicon tracks with cell loading concentration 10 times higher. It also fully utilizes the track to enable cell sliding on both of the up- and down-stream sides. Notably, we also demonstrate that this track is expandable to be V-shape for more advanced bidirectional cell sliding, which is showcased here by tumor cells separation from lymphocytes at 1.2 mL/h. Such results greatly enhance the throughput as compared to the state-of-art conducting-PDMS based cell separator

    Correlative intravital imaging of cGMP signals and vasodilation in mice

    Get PDF
    Cyclic guanosine monophosphate (cGMP) is an important signaling molecule and drug target in the cardiovascular system. It is well known that stimulation of the vascular nitric oxide (NO)-cGMP pathway results in vasodilation. However, the spatiotemporal dynamics of cGMP signals themselves and the cGMP concentrations within specific cardiovascular cell types in health, disease, and during pharmacotherapy with cGMP-elevating drugs are largely unknown. To facilitate the analysis of cGMP signaling in vivo, we have generated transgenic mice that express fluorescence resonance energy transfer (FRET)-based cGMP sensor proteins. Here, we describe two models of intravital FRET/cGMP imaging in the vasculature of cGMP sensor mice: (1) epifluorescence-based ratio imaging in resistance-type vessels of the cremaster muscle and (2) ratio imaging by multiphoton microscopy within the walls of subcutaneous blood vessels accessed through a dorsal skinfold chamber. Both methods allow simultaneous monitoring of NO-induced cGMP transients and vasodilation in living mice. Detailed protocols of all steps necessary to perform and evaluate intravital imaging experiments of the vasculature of anesthetized mice including surgery, imaging, and data evaluation are provided. An image segmentation approach is described to estimate FRET/cGMP changes within moving structures such as the vessel wall during vasodilation. The methods presented herein should be useful to visualize cGMP or other biochemical signals that are detectable with FRET-based biosensors, such as cyclic adenosine monophosphate or Ca2+, and to correlate them with respective vascular responses. With further refinement and combination of transgenic mouse models and intravital imaging technologies, we envision an exciting future, in which we are able to “watch” biochemistry, (patho-)physiology, and pharmacotherapy in the context of a living mammalian organism

    Micelle-Encapsulated Quantum Dot-Porphyrin Assemblies as

    Get PDF
    Micelles have been employed to encapsulate the supramolecular assembly of quantum dots with palladium(II) porphyrins for the quantification of O₂ levels in aqueous media and in vivo. Förster resonance energy transfer from the quantum dot (QD) to the palladium porphyrin provides a means for signal transduction under both one- and two-photon excitation. The palladium porphyrins are sensitive to O₂ concentrations in the range of 0–160 Torr. The micelle-encapsulated QD-porphyrin assemblies have been employed for in vivo multiphoton imaging and lifetime-based oxygen measurements in mice with chronic dorsal skinfold chambers or cranial windows. Our results establish the utility of the QD-micelle approach for in vivo biological sensing applications.National Cancer Institute (U.S.) (R01- CA126642)International Society for Neurochemistry (W911NF-07-D-0004)United States. Dept. of Energy. Office of Basic Energy Sciences (DE-SC0009758

    Angiotensin inhibition enhances drug delivery and potentiates chemotherapy by decompressing tumour blood vessels

    Get PDF
    Cancer and stromal cells actively exert physical forces (solid stress) to compress tumour blood vessels, thus reducing vascular perfusion. Tumour interstitial matrix also contributes to solid stress, with hyaluronan implicated as the primary matrix molecule responsible for vessel compression because of its swelling behaviour. Here we show, unexpectedly, that hyaluronan compresses vessels only in collagen-rich tumours, suggesting that collagen and hyaluronan together are critical targets for decompressing tumour vessels. We demonstrate that the angiotensin inhibitor losartan reduces stromal collagen and hyaluronan production, associated with decreased expression of profibrotic signals TGF-β1, CCN2 and ET-1, downstream of angiotensin-II-receptor-1 inhibition. Consequently, losartan reduces solid stress in tumours resulting in increased vascular perfusion. Through this physical mechanism, losartan improves drug and oxygen delivery to tumours, thereby potentiating chemotherapy and reducing hypoxia in breast and pancreatic cancer models. Thus, angiotensin inhibitors—inexpensive drugs with decades of safe use—could be rapidly repurposed as cancer therapeutics.National Cancer Institute (U.S.) (Grant P01-CA080124)National Cancer Institute (U.S.) (Grant R01-CA126642)National Cancer Institute (U.S.) (Grant R01-CA085140)National Cancer Institute (U.S.) (Grant R01-CA115767)National Cancer Institute (U.S.) (Grant R01-CA098706)United States. Dept. of Defense. Breast Cancer Research Program (Innovator Award W81XWH-10-1-0016)Lustgarten Foundation (Dana-Farber Cancer Institute/David H. Koch Institute for Integrative Cancer Research at MIT Bridge Project Grant

    Ultra-low-dose spectral-detector computed tomography for the accurate quantification of pulmonary nodules: an anthropomorphic chest phantom study

    Get PDF
    PURPOSETo assess the quantification accuracy of pulmonary nodules using virtual monoenergetic images (VMIs) derived from spectral-detector computed tomography (CT) under an ultra-low-dose scan protocol.METHODSA chest phantom consisting of 12 pulmonary nodules was scanned using spectral-detector CT at 100 kVp/10 mAs, 100 kVp/20 mAs, 120 kVp/10 mAs, and 120 kVp/30 mAs. Each scanning protocol was repeated three times. Each CT scan was reconstructed utilizing filtered back projection, hybrid iterative reconstruction, iterative model reconstruction (IMR), and VMIs of 40–100 keV. The signal-to-noise ratio and air noise of images, absolute differences, and absolute percentage measurement errors (APEs) of the diameter, density, and volume of the four scan protocols and ten reconstruction images were compared.RESULTSWith each fixed reconstruction image, the four scanning protocols exhibited no significant differences in APEs for diameter and density (all P > 0.05). Of the four scan protocols and ten reconstruction images, APEs for nodule volume had no significant differences (all P > 0.05). At 100 kVp/10 mAs, APEs for density using IMR were the lowest (APE-mean: 6.69), but no significant difference was detected between VMIs at 50 keV (APE-mean: 11.69) and IMR (P = 0.666). In the subgroup analysis, at 100 kVp/10 mAs, there were no significant differences between VMIs at 50 keV and IMR in diameter and density (all P > 0.05). The radiation dose at 100 kVp/10 mAs was reduced by 77.8% compared with that at 120 kVp/30 mAs.CONCLUSIONCompared with IMR, reconstruction at 100 kVp/10 mAs and 50 keV provides a more accurate quantification of pulmonary nodules, and the radiation dose is reduced by 77.8% compared with that at 120 kVp/30 mAs, demonstrating great potential for ultra-low-dose spectral-detector CT
    • …
    corecore