17 research outputs found

    Computed Analysis of Three-Dimensional Cone-Beam Computed Tomography Angiography for Determination of Tumor-Feeding Vessels During Chemoembolization of Liver Tumor: A Pilot Study

    Get PDF
    The purpose of this study was to evaluate computed analysis of three-dimensional (3D) cone-beam computed tomography angiography (CTA) of the liver for determination of subsegmental tumor-feeding vessels (FVs). Eighteen consecutive patients underwent transarterial chemoembolization (TACE) from January to October 2008 for 25 liver tumors (15 hepatocellular carcinomas [HCCs] and 10 neuroendocrine metastases). Anteroposterior projection angiogram (two-dimensional [2D]) and 3D cone-beam CTA images were acquired by injection of the common hepatic artery. Retrospectively, FVs were independently identified by three radiology technologists using a software package (S) that automatically determines FVs by analysis of 3D images. Subsequently, three interventional radiologists (IRs) independently identified FVs by reviewing the 2D images followed by examination of the 3D images. Finally, the “ground truth” for the number and location of FVs was obtained by consensus among the IRs, who were allowed to use any imaging―including 2D, 3D, and all oblique or selective angiograms―for such determination. Sensitivities, durations, and degrees of agreement for review of 2D, 3D, and S results were evaluated. Sensitivity of 3D (73%) was higher than 2D (64%) images for identification of FVs (P = 0.036). The sensitivity of S (93%) was higher than 2D (P = 0.02) and 3D (P = 0.005) imaging. The duration for review of 3D imaging was longer than that for 2D imaging (187 vs. 94 s, P = 0.0001) or for S (135 s, P = 0.0001). The degree of agreement between the IRs using 2D and 3D imaging were 54% and 62%, respectively, whereas it was 82% between the three radiology technologists using S. These preliminary data show that computed determination of FVs is both accurate and sensitive

    Thermal ablation of ultrasound and non-contrast computed tomography invisible primary and secondary liver tumors: targeting by selective intra-arterial lipiodol injection

    Get PDF
    PURPOSETo evaluate the technical feasibility and outcomes of thermal ablation following selective intra-arterial lipiodol injection (SIALI) for targeting primary and secondary liver tumors invisible on ultrasound (US) and non-contrast computed tomography (CT).METHODSThis retrospective study included 18 patients with 20 tumors (67% male, mean age 60.8 ± 12.1 years). The 20 tumors included 15 liver metastases and 5 hepatocellular carcinomas. All patients underwent single-session SIALI and subsequent CT-guided thermal ablation. The primary outcome was a technical success, defined as visualization of the tumor after SIALI and successful thermal ablation. Secondary outcomes were local recurrence rate and procedure-related complications.RESULTSThe median tumor size was 1.5 (1–2.5) cm. In addition, SIALI was performed with a median volume of 3 (1–10) mL of lipiodol resulting in intra-tumoral iodized oil accumulation in 19 tumors and negative imprint with iodized oil accumulation of the surrounding liver parenchyma in 1 tumor. The technical success rate was 100%. No local occurrence was observed at a mean follow-up time of 3 ± 2.5 years.CONCLUSIONSIALI to tag liver tumors not visible with US and non-contrast CT before percutaneous ablation is highly feasible and has a high success rate for the treatment of both primary and secondary liver tumors

    Le transjugular intrahepatic portosystemic shunt (TIPS) dans le syndrome de Budd-Chiari

    No full text
    PARIS5-BU Méd.Cochin (751142101) / SudocPARIS-BIUM (751062103) / SudocSudocFranceF

    Prostate Artery Embolization: Challenges, Tips, Tricks, and Perspectives

    No full text
    Prostatic artery embolization (PAE) consists of blocking the arteries supplying the prostate to treat benign prostate hypertrophia (BPH). Its effectiveness on both urinary symptoms and flowmetric parameters has now been amply demonstrated by around a hundred studies, including several randomized trials. The main advantage of this procedure is the very low rate of urinary and sexual sequelae, including ejaculatory, with an excellent tolerance profile. The arterial anatomy is a key element for the realization of PAE. Its knowledge makes it possible to anticipate obstacles and prevent potential complications related to nontarget embolization. Nontarget embolization can occur with a small intraprostatic shunt or reflux and has no consequences except some local inflammation symptoms that resolve in a couple of days. Nevertheless, some situations with large arterial shunts arising from the prostatic artery must be recognized (accessory rectal, bladder, or pudendal branches), and must imperatively be protected before embolization, at the risk of exposing oneself to otherwise ischemic complications that are more severe, such as bladder necrosis and skin or mucosal necrosis. This article offers a step-by-step review of the various anatomical and technical key points to ensure technical and clinical success, while avoiding the occurrence of adverse events

    Thermal Ablation Combined with Selective Transarterial Embolization of Centrally Located Renal Cell Carcinomas Measuring 3 cm or Larger

    Full text link
    PURPOSE The purpose of this study was to evaluate the long-term outcomes of patients with centrally located renal cell carcinomas (RCC) measuring 3 cm or larger, treated by a standardized transarterial embolization protocol associated with percutaneous ablation. MATERIALS AND METHODS This retrospective study included 11 patients (73% male, mean age 73.4 ± 6.5 years) with RCC and contraindications for surgery. All patients underwent a single session combining transarterial embolization with iodized oil and subsequent thermal percutaneous ablation. Primary and secondary local tumor control were analyzed, defined as absence of any contrast enhancing nodular lesion in the treated area after a single or percutaneous re-treatment session, respectively. RESULTS Mean tumor size was 3.5 ± 0.3 cm (range 3-4 cm) with a mean R.E.N.A.L. nephrometry score ((R)adius; (E)xophytic, endophytic properties; (N)earness to the collecting system; (A)nterior, posterior; (L)ocation relative to the polar line) of 8 ± 0.9 (range 7-9). Nearness to the collecting system was 4-7 mm in two patients (18%) and ≤ 4 mm in nine patients (82%). After a mean follow-up of 5.2 ± 2.5 years primary and secondary local tumor control rate were 82% and 100%, respectively. No change in serum creatinine levels and glomerular filtration rate was observed compared to pre-treatment values. CONCLUSION A combined treatment of selective transarterial embolization and percutaneous ablation of large centrally located RCC (> 3 cm) is safe, feasible and can achieve excellent oncological long-term results. Larger prospective studies are needed

    Single-session transarterial chemoembolization combined with percutaneous thermal ablation in liver metastases 3 cm or larger

    Full text link
    PURPOSE The purpose of this study was to evaluate the safety and efficacy of transarterial chemoembolization (TACE) combined with percutaneous thermal ablation in patients with liver metastases 3 cm in diameter or larger. MATERIALS AND METHODS This retrospective study included 39 patients with a total of 46 liver metastases treated. There were 14 men and 25 women, with a mean age of 55 ± 13.3 (SD) (age range: 28-77 years). All patients were treated with a combination of TACE and thermal ablation in a single session. Primary outcome was local tumor progression. Secondary outcomes were procedure related complications and systemic disease progression. RESULTS Mean tumor size was 3.6 ± 0.6 (SD) cm (range: 3-5 cm). Conventional TACE was performed in 32 liver metastases (32/46; 70%) and drug-eluting beads-TACE in 14 liver metastases (14/46; 30%) followed by radiofrequency ablation in 34 (34/46; 74%), microwave ablation in 11 (11/46; 24%) and cryoablation in one (1/46; 2%) metastasis. Four grade 2 (4/39; 10%) complications were observed. After a mean follow up of 31.9 ± 26.1 (SD) months (range: 2-113 months) overall local tumor progression rate was 15% (7/46). Local tumor progression rate at 12 months was 13% (6/46). Overall systemic disease progression was seen in 29 patients (29/39; 74%) with a systemic disease progression rate at 12 months of 59% (23/39). CONCLUSION Treatment of large liver metastases with TACE and thermal ablation in a single session is safe and achieves high local control rate

    Percutaneous Fixation of Impending Fracture of the Hip

    Full text link
    According to the literature, prophylactic consolidation of proximal femur lytic metastasis the is recommended when the Mirels' score is above 8. Osteoplasty (cementoplasty of proximal femur) alone provides inadequate consolidation. Various mini-invasive technics, augmented osteoplasties, have been proposed for better long-term consolidation. The aim of this review is to detail the augmented osteoplasty techniques described in the literature and to report their safeties and efficacies to prevent pathological fracture of the proximal femur. A PubMed research found 8 studies that evaluated augmented osteoplasty of the proximal femur in cancer patients. All devices demonstrate adequate safety and low rate of secondary pathological fractures

    Lung microwave ablation – an in vivo swine tumor model experiment to evaluate ablation zones

    No full text
    Purpose To evaluate microwave ablation (MWA) algorithms, comparing pulsed and continuous mode in an in vivo lung tumor mimic model Materials and methods A total of 43 lung tumor-mimic models of 1, 2 or 3 cm were created in 11 pigs through an intra-pulmonary injection of contrast-enriched minced muscle. Tumors were ablated under fluoroscopic and 3D-CBCT-guidance using a single microwave antenna. Continuous (CM) and pulsed mode (PM) were used. According to tumor size, 3 different algorithms for both continuous and pulsed mode were used. The ablation zones were measured using post-procedural 3D-CBCT and on pathologic specimens. Results Two radiologists measured the ablation zones on CBCT and they significantly correlated with macroscopic and microscopic pathological findings: r = 0.75 and 0.74 respectively (p < 0.0001) (inter-observer correlation r = 0.9). For 1, 2 and 3 cm tumors mimics lesions (TMLs), mean maximal and transverse ablation diameters were 3.6  0.3 × 2.2  0.3 cm; 4.1  0.5 × 2.6  0.3 cm and 4.8  0.3 × 3.2  0.3 cm respectively using CM; And, 3.0  0.2 × 2.1  0.2 cm; 4.0  0.4 × 2.7  0.4 cm and 4.6  0.4 × 3.2  0.4 cm respectively for PM, without any significant difference except for 1 cm TMLs treated by PM ablation which were significantly smaller (p = 0.009) The sphericity index was 1.6, 1.6, 1.5 and 1.4, 1.5, 1.4 at 1, 2 and 3 cm for CM and PM respectively, p = 0.07, 0.14 and 0.13 for 1, 2 and 3 cm tumors mimics. Conclusion Microwave ablation for 1–3 cm lung tumors were successfully realized but with a moderate reproducibility rate, using either CM or PM. Immediate post ablation CBCT can accurately evaluate ablation zones

    Coil Embolization of Variant Hepatic Arteries During Percutaneous Arterial Port Catheter Placement for Intraarterial Chemotherapy: Analysis of Intrahepatic Perfusion Redistribution and Treatment Efficacy

    Full text link
    PURPOSE The purpose of this study was to analyze the intrahepatic perfusion redistribution after embolization of hepatic arterial variants during percutaneous arterial port catheter placement as well as to investigate the treatment efficacy of intraarterial chemotherapy in perfusion redistribution-dependent compared to redistribution-independent liver areas. MATERIALS AND METHODS This retrospective study included 62 patients (67.7% males, mean age of 56 ± 12 years). A replaced left hepatic artery was encountered in 36/62 (58.1%), a replaced right hepatic artery in 19/62 (30.6%) and a replaced left and right hepatic artery in 7/62 of patients (11.3%), respectively. Subjective perfusion analysis was performed on digital subtracted angiography and computed tomography (CT)/cone-beam computed tomography (CBCT) images evaluating the visibility of the main, segmental and subsegmental branches of the embolized variant hepatic artery, re-perfused from intrahepatic arterial anastomoses. For objective perfusion analysis ROI measurements on CT/CBCT images were taken in the redistribution-dependent and redistribution-independent liver lobe. Response analysis according to RECIST 1.1 was separately calculated for the redistribution-dependent and redistribution-independent liver lobe. RESULTS Intrahepatic reperfusion of the embolized variant hepatic artery was observed immediately after embolization with visualization of the subsegmental branches in 95.2% of patients. ROI measurements on CT/CBCT images (right lobe mean 76 ± 30.2 HU, left lobe mean 74.4 ± 30.5, p-value 0.88) did not show any differences. Treatment response after intraarterial chemotherapy did not differ between the redistribution-dependent and redistribution-independent liver lobes. CONCLUSION Embolization of hepatic arterial variants during percutaneous arterial port catheter placement results in effective intrahepatic perfusion redistribution and does not compromise treatment efficacy of intraarterial chemotherapy in the redistribution-dependent liver lobe
    corecore