24 research outputs found

    Fielding the magnetically applied pressure-shear technique on the Z accelerator (completion report for MRT 4519).

    Get PDF
    The recently developed Magnetically Applied Pressure-Shear (MAPS) experimental technique to measure material shear strength at high pressures on magneto-hydrodynamic (MHD) drive pulsed power platforms was fielded on August 16, 2013 on shot Z2544 utilizing hardware set A0283A. Several technical and engineering challenges were overcome in the process leading to the attempt to measure the dynamic strength of NNSA Ta at 50 GPa. The MAPS technique relies on the ability to apply an external magnetic field properly aligned and time correlated with the MHD pulse. The load design had to be modified to accommodate the external field coils and additional support was required to manage stresses from the pulsed magnets. Further, this represents the first time transverse velocity interferometry has been applied to diagnose a shot at Z. All subsystems performed well with only minor issues related to the new feed design which can be easily addressed by modifying the current pulse shape. Despite the success of each new component, the experiment failed to measure strength in the samples due to spallation failure, most likely in the diamond anvils. To address this issue, hydrocode simulations are being used to evaluate a modified design using LiF windows to minimize tension in the diamond and prevent spall. Another option to eliminate the diamond material from the experiment is also being investigated

    The detection, survival and persistence of Staphylococcus capitis NRCS-A in neonatal units in England

    Get PDF
    BACKGROUND: The multi-drug resistant Staphylococcus capitis clone, NRCS-A is increasingly associated with late-onset sepsis in low birthweight newborns in neonatal intensive care units (NICUs) in England and globally. Understanding where this bacterium survives and persists within the NICU environment is key to developing and implementing effective control measures. AIM: To investigate the potential for S. capitis to colonise surfaces within NICUs. METHODS: Surface swabs were collected from four NICUs with and without known NRCS-A colonisations/infections present at the time of sampling. Samples were cultured and S. capitis isolates analysed via whole genome sequencing. Survival of NRCS-A on plastic surfaces was assessed over time and compared to that of non-NRCS-A isolates. The bactericidal activity of commonly used chemical disinfectants against S. capitis was assessed. FINDINGS: Of 173 surfaces sampled, 40 (21.1%) harboured S. capitis with 30 isolates (75%) being NRCS-A. Whilst S. capitis was recovered from surfaces across the NICU, the NRCS-A clone was rarely recovered from outside the immediate neonatal bedspace. Incubators and other bedside equipment were contaminated with NRCS-A regardless of clinical case detection. In the absence of cleaning, S. capitis was able to survive for 3 days with minimal losses in viability (< 0.5 log10 reduction). Sodium troclosene and a QAC-based detergent/disinfectant reduced S. capitis to below detectable levels. CONCLUSION: S. capitis NRCS-A can be readily recovered from the NICU environment, even in units with no recent reported clinical cases of S. capitis infection, highlighting a need for appropriate national guidance on cleaning within the neonatal care environment

    Fun without vulgarity Victorian and Edwardian popular entertainment posters

    No full text
    Available from British Library Document Supply Centre-DSC:OP-96/PRO / BLDSC - British Library Document Supply CentreSIGLEGBUnited Kingdo

    Magnetically applied pressure-shear : a new technique for direct strength measurement at high pressure (final report for LDRD project 117856).

    No full text
    A new experimental technique to measure material shear strength at high pressures has been developed for use on magneto-hydrodynamic (MHD) drive pulsed power platforms. By applying an external static magnetic field to the sample region, the MHD drive directly induces a shear stress wave in addition to the usual longitudinal stress wave. Strength is probed by passing this shear wave through a sample material where the transmissible shear stress is limited to the sample strength. The magnitude of the transmitted shear wave is measured via a transverse VISAR system from which the sample strength is determined
    corecore