7,367 research outputs found

    The effect of coverings, including plastic bags and wraps, on mortality and morbidity in preterm and full-term neonates.

    Get PDF
    Neonatal hypothermia is an important risk factor for mortality and morbidity, and is common even in temperate climates. We conducted a systematic review to determine whether plastic coverings, used immediately following delivery, were effective in reducing the incidence of mortality, hypothermia and morbidity. A total of 26 studies (2271 preterm and 1003 term neonates) were included. Meta-analyses were conducted as appropriate. Plastic wraps were associated with a reduction in hypothermia in preterm (⩽29 weeks; risk ratio (RR)=0.57; 95% confidence interval (CI) 0.46 to 0.71) and term neonates (RR=0.76; 95% CI 0.60 to 0.96). No significant reduction in neonatal mortality or morbidity was found; however, the studies were underpowered for these outcomes. For neonates, especially preterm, plastic wraps combined with other environmental heat sources are effective in reducing hypothermia during stabilization and transfer within hospital. Further research is needed to quantify the effects on mortality or morbidity, and investigate the use of plastic coverings outside hospital settings or without additional heat sources

    The first report of Candida dubliniensis from human root caries lesions

    Get PDF
    published_or_final_versio

    The microflora of root surface caries in Southern Chinese

    Get PDF
    published_or_final_versio

    Environmental and economic assessment of hybrid FO-RO/NF system with selected inorganic draw solutes for the treatment of mine impaired water

    Full text link
    © 2017 Elsevier B.V. A hybrid forward osmosis (FO) and reverse osmosis (RO)/nanofiltration (NF) system in a closed-loop operation with selected draw solutes was evaluated to treat coal mine impaired water. This study provides an insight of selecting the most suitable draw solution (DS) by conducting environmental and economic life cycle assessment (LCA). Baseline environmental LCA showed that the dominant components to energy use and global warming are the DS recovery processes (i.e. RO or NF processes) and FO membrane materials, respectively. When considering the DS replenishment in FO, the contribution of chemical use to the overall global warming impact was significant for all hybrid systems. Furthermore, from an environmental perspective, the FO-NF hybrid system with Na2SO4 shows the lowest energy consumption and global warming with additional considerations of final product water quality and FO brine disposal. From an economic perspective, the FO-NF with Na2SO4 showed the lowest total operating cost due to its lower DS loss and relatively low solute cost. In a closed-loop system, FO-NF with NaCl and Na2SO4 had the lowest total water cost at optimum NF recovery rates of 90 and 95%, respectively. FO-NF with Na2SO4 had the lowest environmental and economic impacts. Overall, draw solute performances and cost in FO and recovery rate in RO/NF play a crucial role in determining the total water cost and environmental impact of FO hybrid systems in a closed-loop operation

    Electron gyroscale fluctuation measurements in National Spherical Torus Experiment H-mode plasmas

    Get PDF
    A collective scattering system has measured electron gyroscale fluctuations in National Spherical Torus Experiment [M. Ono et al., Nucl. Fusion 40, 557 (2000)] H-mode plasmas to investigate electron temperature gradient (ETG) turbulence. Observations and results pertaining to fluctuation measurements in ETG-stable regimes, the toroidal field scaling of fluctuation amplitudes, the relation between fluctuation amplitudes and transport quantities, and fluctuation magnitudes and k-spectra are presented. Collectively, the measurements provide insight and guidance for understanding ETG turbulence and anomalous electron thermal transport. (C) 2009 American Institute of Physics. [doi:10.1063/1.3262530]X116sciescopu

    Hybrid forward osmosis-reverse osmosis for wastewater reuse and seawater desalination: Understanding the optimal feed solution to minimise fouling

    Full text link
    © 2018 Institution of Chemical Engineers To enhance the seawater desalination energy efficiency forward osmosis – reverse osmosis (FO-RO) hybrid system has recently been developed. In this process, the FO “pre-treatment” step is designed to use seawater (SW) as draw solution to filter the wastewater (WW) while reducing the seawater osmotic pressure. Thereby reducing the operating pressure of the RO to desalinate the diluted SW. However, membrane fouling is a major issue that needs to be addressed. Proper selection of suitable WWs is necessary before proceeding with large-scale FO-RO desalination plants. In this study, long-term experiments were carried out, using state-of-the-art FO membrane, using real WW and SW solutions. A combination of water flux modelling and membrane characterisation were used to assess the degree of membrane fouling and the impact on the process performance. Initial water flux as high as 22.5 Lm−2 h−1 was observed when using secondary effluent. It was also found that secondary effluent causes negligible flux decline. On the other hand, biologically treated wastewater and primary effluent caused mild and severe flux decline respectively (25% and 50% of flux decline after 80 hours, compared to no-fouling conditions). Ammonia leakage to the diluted seawater was also measured, concluding that, if biologically treated wastewater is used as feed, the final NH4+ concentration in the draw is likely to be negligible

    Observations of Reduced Electron Gyroscale Fluctuations in National Spherical Torus Experiment H-Mode Plasmas with Large E X B Flow Shear

    Get PDF
    Electron gyroscale fluctuation measurements in National Spherical Torus Experiment H-mode plasmas with large toroidal rotation reveal fluctuations consistent with electron temperature gradient (ETG) turbulence. Large toroidal rotation in National Spherical Torus Experiment plasmas with neutral beam injection generates ExB flow shear rates comparable to ETG linear growth rates. Enhanced fluctuations occur when the electron temperature gradient is marginally stable with respect to the ETG linear critical gradient. Fluctuation amplitudes decrease when the ExB flow shear rate exceeds ETG linear growth rates. The observations indicate that ExB flow shear can be an effective suppression mechanism for ETG turbulence.X1129sciescopu

    The anomalous U(1) global symmetry and flavors from an SU(5) x SU(5)' GUT in Z12IZ_{12-I} orbifold compactification

    Full text link
    In string compactifications, frequently there appears the anomalous U(1) gauge symmetry which belonged to E8×\timesE8 of the heterotic string. This anomalous U(1) gauge boson obtains mass at the compactification scale, just below 101810^{18\,}GeV, by absorbing one pseudoscalar (corresponding to the model-independent axion) from the second rank anti-symmetric tensor field BMNB_{MN}. Below the compactification scale, there results a global symmetry U(1)anom_{\rm anom} whose charge QanomQ_{\rm anom} is the original gauge U(1) charge. This is the most natural global symmetry, realizing the "invisible" axion. This global symmetry U(1)anom_{\rm anom} is suitable for a flavor symmetry. In the simplest compactification model with the flipped SU(5) grand unification, we calculate all the low energy parameters in terms of the vacuum expectation values of the standard model singlets.Comment: 18 pages, 4 figur

    Influence of the process parameters on hollow fiber-forward osmosis membrane performances

    Full text link
    © 2014 Balaban Desalination Publications. All rights reserved. Continued efforts are made in improving the performance of the low-cost forward osmosis (FO) membrane process which utilizes naturally available osmotic pressure of the draw solution (DS) as the driving force. Selection of a suitable DS and development of a better performing membrane remained the main research focus. In this study, the performance of a hollow fiber forward osmosis (HFFO) membrane was evaluated with respect to various operating conditions such as different cross-flow directions, membrane orientation, solution properties, and solution flow rates (Reynolds number). The study observed that operating parameters significantly affect the performance of the FO process. FO comparatively showed better performance at counter-current orientation. NaCl, KCl, and NH4Cl were evaluated as DS carrying common anion. Properties of the anionic part of the DS were found important for flux outcome, whereas reverse solute flux (RSF) was largely influenced by the properties of DS cationic part. FO was operated at different DS and feed solution (FS) flow rates and FO outcome was assessed for varying DS and FS Reynolds number ratio. FO showed better flux outcome as Re ratio for DS and FS decreases and vice versa. Results indicated that by adjusting FO processes conditions, HFFO membrane could achieve significantly lower specific RSF and higher water flux outcome. It was observed that using 2 M NaCl as DS and deionized water as FS, HFFO successfully delivered flux of 62.9 LMH which is significantly high compared to many FO membranes reported in the literature under the active layer-DS membrane orientation mode

    The gradient of potential vorticity, quaternions and an orthonormal frame for fluid particles

    Full text link
    The gradient of potential vorticity (PV) is an important quantity because of the way PV (denoted as qq) tends to accumulate locally in the oceans and atmospheres. Recent analysis by the authors has shown that the vector quantity \bdB = \bnabla q\times \bnabla\theta for the three-dimensional incompressible rotating Euler equations evolves according to the same stretching equation as for \bom the vorticity and \bB, the magnetic field in magnetohydrodynamics (MHD). The \bdB-vector therefore acts like the vorticity \bom in Euler's equations and the \bB-field in MHD. For example, it allows various analogies, such as stretching dynamics, helicity, superhelicity and cross helicity. In addition, using quaternionic analysis, the dynamics of the \bdB-vector naturally allow the construction of an orthonormal frame attached to fluid particles\,; this is designated as a quaternion frame. The alignment dynamics of this frame are particularly relevant to the three-axis rotations that particles undergo as they traverse regions of a flow when the PV gradient \bnabla q is large.Comment: Dedicated to Raymond Hide on the occasion of his 80th birthda
    corecore