12 research outputs found

    A NICER Discovery of a Low-Frequency Quasi-Periodic Oscillation in the Soft-Intermediate State of MAXI J1535-571

    Full text link
    We present the discovery of a low-frequency ≈5.7\approx 5.7 Hz quasi-periodic oscillation (QPO) feature in observations of the black hole X-ray binary MAXI J1535-571 in its soft-intermediate state, obtained in September-October 2017 by the Neutron Star Interior Composition Explorer (NICER). The feature is relatively broad (compared to other low-frequency QPOs; quality factor Q≈2Q\approx 2) and weak (1.9% rms in 3-10 keV), and is accompanied by a weak harmonic and low-amplitude broadband noise. These characteristics identify it as a weak Type A/B QPO, similar to ones previously identified in the soft-intermediate state of the transient black hole X-ray binary XTE J1550-564. The lag-energy spectrum of the QPO shows increasing soft lags towards lower energies, approaching 50 ms at 1 keV (with respect to a 3-10 keV continuum). This large phase shift has similar amplitude but opposite sign to that seen in Rossi X-ray Timing Explorer data for a Type B QPO from the transient black hole X-ray binary GX 339-4. Previous phase-resolved spectroscopy analysis of the Type B QPO in GX 339-4 pointed towards a precessing jet-like corona illuminating the accretion disk as the origin of the QPO signal. We suggest that this QPO in MAXI J1535-571 may have the same origin, with the different lag sign depending on the scale height of the emitting region and the observer inclination angle.Comment: Accepted for publication in ApJ Letter

    Unusual presentation of peritonitis with persistent clear aspirate: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Peritonitis is the most frequent complication of peritoneal dialysis. Diagnosis of peritonitis includes symptoms and signs of peritonitis with a cloudy aspirate of more than 100 WBC/ml, as well as positive cultures. Although sterile peritonitis has been reported in the literature, to the best of our knowledge this is the first report of an unusual presentation of peritonitis without any white blood cells in the peritoneal aspirate despite multiple positive peritoneal cultures.</p> <p>Case presentation</p> <p>An 82-year-old Caucasian man who had been on continuous cycling peritoneal dialysis for 12 years was admitted to our hospital with general malaise, loss of appetite, weight loss and somnolence. He did not describe abdominal pain or fever. Even though his peritoneal fluid was consistently negative for leukocytes and clear, he had peritonitis with different organisms consecutively.</p> <p>Conclusions</p> <p>Our case report shows that any patient on peritoneal dialysis presenting with evidence of infection (fever, peripheral leukocytosis) without an obvious cause should have aspirate cultures done even if the aspirate is clear and abdominal pain is absent. Our case report may change the initial work-up and management of these patients. We believe this report is of interest to general medicine and emergency room physicians as well as nephrologists.</p

    A NICER discovery of a low-frequency quasi-periodic oscillation in the soft-intermediate state of MAXI J1535–571

    No full text
    We present the discovery of a low-frequency ≈5.7 Hz quasi-periodic oscillation (QPO) feature in observations of the black hole X-ray binary MAXI J1535-571 in its soft-intermediate state, obtained in 2017 September-October by the Neutron Star Interior Composition Explorer. The feature is relatively broad (compared to other low-frequency QPOs; quality factor Q ≈ 2) and weak (1.9% rms in 3-10 keV), and is accompanied by a weak harmonic and low-amplitude broadband noise. These characteristics identify it as a weak Type A/B QPO, similar to ones previously identified in the soft-intermediate state of the transient black hole X-ray binary XTE J1550-564. The lag-energy spectrum of the QPO shows increasing soft lags toward lower energies, approaching 50 ms at 1 keV (with respect to a 3-10 keV continuum). This large phase shift has similar amplitude but opposite sign to that seen in Rossi X-Ray Timing Explorer data for a Type B QPO from the transient black hole X-ray binary GX 339-4. Previous phase-resolved spectroscopy analysis of the Type B QPO in GX 339-4 pointed toward a precessing jet-like corona illuminating the accretion disk as the origin of the QPO signal. We suggest that this QPO in MAXI J1535-571 may have the same origin, with the different lag sign depending on the scale height of the emitting region and the observer inclination angle

    Update on the challenging role of biofilms in peritoneal dialysis

    No full text
    Biofilms are commonly associated with an increased risk of patient infection. In peritoneal dialysis (PD), catheter associ- ated infection, especially peritonitis, remains a clinically relevant problem. Although the presence of a biofilm is recog- nized in relapsing, repeat, and catheter-related peritonitis, it remains poorly characterized. In this review, an update on the role of biofilms in PD infections is presented. The emerging concept that host cells and tissue associated biofilms, in addition to the biofilms on the catheters themselves, contribute to the recalcitrance of infections is discussed. Further- more, the evidence of biofilms on PD catheters, their developmental stages, and the possible influence of the PD envi- ronment are reviewed. The focus is given to ex vivo and in vitro studies that contribute to the elucidation of the interplay between host, microbial, and dialysis factors. The key issues that are still to be answered and the challenges to clinical practice are discussed.Sociedade Portuguesa de Nefrologi

    Systemic Inflammatory Syndrome and Hepatic Inflammatory Cell Infiltration Caused by an Interleukin-6 Producing Pheochromocytoma

    No full text
    corecore