19 research outputs found

    Transport properties of dense fluid argon

    Full text link
    We calculate using molecular dynamics simulations the transport properties of realistically modeled fluid argon at pressures up to 50GPa\simeq 50GPa and temperatures up to 3000K3000K. In this context we provide a critique of some newer theoretical predictions for the diffusion coefficients of liquids and a discussion of the Enskog theory relevance under two different adaptations: modified Enskog theory (MET) and effective diameter Enskog theory. We also analyze a number of experimental data for the thermal conductivity of monoatomic and small diatomic dense fluids.Comment: 8 pages, 6 figure

    Yeast Two-Hybrid: State of the Art

    Get PDF
    Genome projects are approaching completion and are saturating sequence databases. This paper discusses the role of the two-hybrid system as a generator of hypotheses. Apart from this rather exhaustive, financially and labour intensive procedure, more refined functional studies can be undertaken. Indeed, by making hybrids of two-hybrid systems, customised approaches can be developed in order to attack specific function-related problems. For example, one could set-up a "differential" screen by combining a forward and a reverse approach in a three-hybrid set-up. Another very interesting project is the use of peptide libraries in two-hybrid approaches. This could enable the identification of peptides with very high specificity comparable to "real" antibodies. With the technology available, the only limitation is imagination

    A review of symptomatic leg length inequality following total hip arthroplasty

    Get PDF
    Leg length inequality (LLI) following total hip replacement is a complication which features increasingly in the recent literature. The definition of LLI is complicated by lack of consensus regarding radiological measurement, clinical measurement and the incomplete relationship between LLI and associated symptoms. This paper reviews 79 reports relating to LLI post hip replacement, detailing definitions and classification and highlighting patient populations prone to symptomatic LLI. While there is no universal definition of LLI, there is a broad consensus that less than 10 mm of difference on AP view plain radiographs is clinically acceptable. There are few techniques described that consistently produce a postoperative LLI of less than this magnitude. Where postoperative LLI exists, lengthening appears to cause more problems than shortening. In cases of mild LLI, non-surgical management produces adequate outcomes in the majority of cases, with functional LLI cases doing better than those with true LLI. Operative correction is effective in half of cases, even where nerve palsy is present, and remains an important option of last resort. Poor outcomes in patients with LLI may be minimised if individuals at risk are identified and counselled appropriately

    The Thermal Conductivity of Oxygen

    No full text
    The paper presents new experimental measurements of the thermal conductivity of oxygen for thirteen isotherms at temperatures from 78 to 310 K with pressures to 70 MPa and densities from 0 to 40 mol/L. The measurements were made with a transient hot wire apparatus and they cover a wide range of physical states including the dilute gas, the moderately dense gas, the near critical region, the compressed liquid states, and the vapor at temperatures below the critical temperature. The thermal conductivity surface is represented with an equation that is based in part on an existing correlation of the dilute gas. The data are compared with the experimental measurements of others through the new correlation. The new measurements show that the critical enhancement extends to quite high temperatures, about 300 K. The precision (2o) of the oxygen measurements is between 0.5 and 0.8 percent for wire temperature transients of 4 to 5 K, while the accuracy is estimated to be 1.5 percent

    A high-temperature transient hot-wire thermal conductivity apparatus for fluids

    No full text
    A new apparatus for measuring both the thermal conductivity and thermal diffusivity of fluids at temperatures from 220 to 775 K at pressures to 70 MPa is described. The instrument is based on the step-power-forced transient hot-wire technique. Two hot wires are arranged in different arms of a Wheatstone bridge such that the response of the shorter compensating wire is subtracted from the response of the primary wire. Both hot wires are 12.7 µm diameter platinum wire and are simultaneously used as electrical heat sources and as resistance thermometers. A microcomputer controls bridge nulling, applies the power pulse, monitors the bridge response, and stores the results. Performance of the instrument was verified with measurements on liquid toluene as well as argon and nitrogen gas. In particular, new data for the thermal conductivity of liquid toluene near the saturation line, between 298 and 550 K, are presented. These new data can be used to illustrate the importance of radiative heat transfer in transient hot-wire measurements. Thermal conductivity data for liquid toluene, which are corrected for radiation, are reported. The precision of the thermal conductivity data is ± 0.3% and the accuracy is about ±1%. The accuracy of the thermal diffusivity data is about ± 5%. From the measured thermal conductivity and thermal diffusivity, we can calculate the specific heat, C(p), of the fluid, provided that the density is measured, or available through an equation of state

    Stable High Concentration Matrix Isolation of High Energy Species

    No full text
    corecore