8 research outputs found

    THE SOURCE OF UNCERTAINTY IN 3D LASER SCANNER

    Get PDF
    3D laser scanner become popular in manufacturing field because of its capability in measuring various characteristics of part and reverse engineering. It is found that laser scanner which categorize under non-contact method is less accurate compared to the contact method. This is due to the output quality that depending on digitizing points captured during scanning. These digitizing points are affected from extrinsic and intrinsic parameters. Some of the parameters for commercial lasers are already calibrated prior to delivery. In this paper, extrinsic parameters are discussed based on LC15 laser scanner with Metris scan 4.1 software. A suggestion on model of uncertainty is suggested based on propagation of uncertainty method align with the understanding of extrinsic scanning parameters

    Significance of continuous rotavirus and norovirus surveillance in Indonesia

    No full text

    The impact of the COVID-19 pandemic on UK medical education. A nationwide student survey

    No full text

    Serious Asthma Events with Fluticasone plus Salmeterol versus Fluticasone Alone

    No full text
    BACKGROUND: The safe and appropriate use of long-acting beta-agonists (LABAs) for the treatment of asthma has been widely debated. In two large clinical trials, investigators found a potential risk of serious asthma-related events associated with LABAs. This study was designed to evaluate the risk of administering the LABA salmeterol in combination with an inhaled glucocorticoid, fluticasone propionate. METHODS: In this multicenter, randomized, double-blind trial, adolescent and adult patients (age, ≥12 years) with persistent asthma were assigned to receive either fluticasone with salmeterol or fluticasone alone for 26 weeks. All the patients had a history of a severe asthma exacerbation in the year before randomization but not during the previous month. Patients were excluded from the trial if they had a history of life-threatening or unstable asthma. The primary safety end point was the first serious asthma-related event (death, endotracheal intubation, or hospitalization). Noninferiority of fluticasone-salmeterol to fluticasone alone was defined as an upper boundary of the 95% confidence interval for the risk of the primary safety end point of less than 2.0. The efficacy end point was the first severe asthma exacerbation. RESULTS: Of 11,679 patients who were enrolled, 67 had 74 serious asthma-related events, with 36 events in 34 patients in the fluticasone-salmeterol group and 38 events in 33 patients in the fluticasone-only group. The hazard ratio for a serious asthma-related event in the fluticasone-salmeterol group was 1.03 (95% confidence interval [CI], 0.64 to 1.66), and noninferiority was achieved (P=0.003). There were no asthma-related deaths; 2 patients in the fluticasone-only group underwent asthma-related intubation. The risk of a severe asthma exacerbation was 21% lower in the fluticasone-salmeterol group than in the fluticasone-only group (hazard ratio, 0.79; 95% CI, 0.70 to 0.89), with at least one severe asthma exacerbation occurring in 480 of 5834 patients (8%) in the fluticasone-salmeterol group, as compared with 597 of 5845 patients (10%) in the fluticasone-only group (P<0.001). CONCLUSIONS: Patients who received salmeterol in a fixed-dose combination with fluticasone did not have a significantly higher risk of serious asthma-related events than did those who received fluticasone alone. Patients receiving fluticasone-salmeterol had fewer severe asthma exacerbations than did those in the fluticasone-only group
    corecore