187 research outputs found

    Analysis of lesion localisation at colonoscopy: outcomes from a multi-centre U.K. study

    Get PDF
    Background: Colonoscopy is currently the gold standard for detection of colorectal lesions, but may be limited in anatomically localising lesions. This audit aimed to determine the accuracy of colonoscopy lesion localisation, any subsequent changes in surgical management and any potentially influencing factors. Methods: Patients undergoing colonoscopy prior to elective curative surgery for colorectal lesion/s were included from 8 registered U.K. sites (2012–2014). Three sets of data were recorded: patient factors (age, sex, BMI, screener vs. symptomatic, previous abdominal surgery); colonoscopy factors (caecal intubation, scope guide used, colonoscopist accreditation) and imaging modality. Lesion localisation was standardised with intra-operative location taken as the gold standard. Changes to surgical management were recorded. Results: 364 cases were included; majority of lesions were colonic, solitary, malignant and in symptomatic referrals. 82% patients had their lesion/s correctly located at colonoscopy. Pre-operative CT visualised lesion/s in only 73% of cases with a reduction in screening patients (64 vs. 77%; p = 0.008). 5.2% incorrectly located cases at colonoscopy underwent altered surgical management, including conversion to open. Univariate analysis found colonoscopy accreditation, scope guide use, incomplete colonoscopy and previous abdominal surgery significantly influenced lesion localisation. On multi-variate analysis, caecal intubation and scope guide use remained significant (HR 0.35, 0.20–0.60 95% CI and 0.47; 0.25–0.88, respectively). Conclusion: Lesion localisation at colonoscopy is incorrect in 18% of cases leading to potentially significant surgical management alterations. As part of accreditation, colonoscopists need lesion localisation training and awareness of when inaccuracies can occur

    Effects of pulsed electric field on the viscoelastic properties of potato tissue

    Get PDF
    We have investigated whether transient permeabilization caused by the application of pulsed electric field would give rise to transient changes in the potato tissue viscoelastic properties. Potato tissue was subjected to nominal field strengths (E) ranging from 30 to 500 V/cm, with a single rectangular pulse of 10−5, 10−4, or 10−3 s. The changes on the viscoelastic properties of potato tissue during pulsed electric fields (PEF) were monitored through small amplitude oscillatory dynamic rheological measurements. The elastic (G′) and viscous moduli (G″) were measured every 30 s after the delivery of the pulse and the loss tangent change (tan-δ) was calculated. The results were correlated with measurements of changes on electrical resistance during the delivery of the pulse. Results show a drastic increase of tan-δ in the first 30 s after the application of the pulse, followed by a decrease 1 min after pulsation. This response is strongly influenced by pulsing conditions and is independent of the total permeabilization achieved by the pulse. Our results, supported by similar measurements on osmotically dehydrated control samples, clearly show that PEF causes a rapid change of the viscoelastic properties of the tissue that could be attributed to a partial loss in turgor pressure. This would be an expected consequence of electroporation. The recovery of tan-δ to values similar to those before pulsation strongly suggests recovery of cell membrane properties and turgor, pointing at reversible permeabilization of the cells. A slight increase of stiffness traduced by a negative change of tan-δ after application of certain PEF conditions may also give an indication of events occurring on cell wall structure due to stress responses. This study set the basis for further investigations on the complex cell stress physiology involving both cell membrane functional properties and cell wall structure that would influence tissue physical properties upon PEF application.Fundação para a Ciência e a Tecnologia (FCT

    Living with autism without knowing: receiving a diagnosis in later life

    Get PDF
    Increasingly adults over the age of 50 are receiving a diagnosis of autism spectrum condition. Growing up in a time when autism was poorly recognised, these adults have lived unknowingly with the condition and face readjustment. This paper reports the first study to investigate this population. Nine adults over the age of 50, who had recently been diagnosed with ASC, were interviewed, and thematic analysis was used to analyse the transcripts. Results showed that the participants had received treatment for anxiety and depression. They reported ASC behaviours in their childhood and growing up they felt isolated and alien. Receiving a diagnosis was seen as a positive step and allowed for a reconfiguration of self and an appreciation of individual needs. Given the positive aspects of receiving a late diagnosis, more work is needed to identify older adults with undiagnosed ASC

    Unconventional Low-Cost Fabrication and Patterning Techniques for Point of Care Diagnostics

    Get PDF
    The potential of rapid, quantitative, and sensitive diagnosis has led to many innovative ‘lab on chip’ technologies for point of care diagnostic applications. Because these chips must be designed within strict cost constraints to be widely deployable, recent research in this area has produced extremely novel non-conventional micro- and nano-fabrication innovations. These advances can be leveraged for other biological assays as well, including for custom assay development and academic prototyping. The technologies reviewed here leverage extremely low-cost substrates and easily adoptable ways to pattern both structural and biological materials at high resolution in unprecedented ways. These new approaches offer the promise of more rapid prototyping with less investment in capital equipment as well as greater flexibility in design. Though still in their infancy, these technologies hold potential to improve upon the resolution, sensitivity, flexibility, and cost-savings over more traditional approaches
    corecore