28 research outputs found

    Abnormal shortened diastolic time length at increasing heart rates in patients with abnormal exercise-induced increase in pulmonary artery pressure

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The degree of pulmonary hypertension is not independently related to the severity of left ventricular systolic dysfunction but is frequently associated with diastolic filling abnormalities. The aim of this study was to assess diastolic times at increasing heart rates in normal and in patients with and without abnormal exercise-induced increase in pulmonary artery pressure (PASP). Methods. We enrolled 109 patients (78 males, age 62 ± 13 years) referred for exercise stress echocardiography and 16 controls. The PASP was derived from the tricuspid Doppler tracing. A cut-off value of PASP ≥ 50 mmHg at peak stress was considered as indicative of abnormal increase in PASP. Diastolic times and the diastolic/systolic time ratio were recorded by a precordial cutaneous force sensor based on a linear accelerometer.</p> <p>Results</p> <p>At baseline, PASP was 30 ± 5 mmHg in patients and 25 ± 4 in controls. At peak stress the PASP was normal in 95 patients (Group 1); 14 patients (Group 2) showed an abnormal increase in PASP (from 35 ± 4 to 62 ± 12 mmHg; P < 0.01). At 100 bpm, an abnormal (< 1) diastolic/systolic time ratio was found in 0/16 (0%) controls, in 12/93 (13%) Group 1 and 7/14 (50%) Group 2 patients (p < 0.05 between groups).</p> <p>Conclusion</p> <p>The first and second heart sound vibrations non-invasively monitored by a force sensor are useful for continuously assessing diastolic time during exercise. Exercise-induced abnormal PASP was associated with reduced diastolic time at heart rates beyond 100 beats per minute.</p

    Cardiovascular magnetic resonance in pericardial diseases

    Get PDF
    The pericardium and pericardial diseases in particular have received, in contrast to other topics in the field of cardiology, relatively limited interest. Today, despite improved knowledge of pathophysiology of pericardial diseases and the availability of a wide spectrum of diagnostic tools, the diagnostic challenge remains. Not only the clinical presentation may be atypical, mimicking other cardiac, pulmonary or pleural diseases; in developed countries a shift for instance in the epidemiology of constrictive pericarditis has been noted. Accurate decision making is crucial taking into account the significant morbidity and mortality caused by complicated pericardial diseases, and the potential benefit of therapeutic interventions. Imaging herein has an important role, and cardiovascular magnetic resonance (CMR) is definitely one of the most versatile modalities to study the pericardium. It fuses excellent anatomic detail and tissue characterization with accurate evaluation of cardiac function and assessment of the haemodynamic consequences of pericardial constraint on cardiac filling. This review focuses on the current state of knowledge how CMR can be used to study the most common pericardial diseases

    Preventing protein adsorption from a range of surfaces using an aqueous fish protein extract

    No full text
    We utilize an aqueous extract of fish proteins (FPs) as a coating for minimizing the adsorption of fibrinogen (Fg) and human serum albumin (HSA). The surfaces include stainless steel (SS), gold (Au), silicon dioxide (SiO 2), and poly(styrene) (PS). The adsorption processes (kinetics and adsorbed mass) are followed by quartz crystal microbalance with dissipation (QCM-D). Complementary surface information is provided by X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM). QCM-D shows no mass increases to any of the FPcoated surfaces upon treating with Fg or HSA. Also, when Fg- or HSA-coated surfaces are exposed to the FPs, a significant increase in adsorbed mass occurs because the FPs are highly surface-active displacing Fg. Additionally, fluorescence microscopy confirms that very little Fg adsorbs to the FP-coated surfaces. We propose that FP coatings prevent protein adsorption by steric stabilization and could be an alternative method for preventing unwanted bioadhesion on medical materials
    corecore