22 research outputs found

    Nouvelle technique de détection des shunts gauche-droit par la méthode au protoxyde d’azote

    No full text
    The left-to-right shunts increase the oxygen content in the right heart, but it may he difficult to reveal these changes in small shunts, whose theoretical and practical interest must he emphasized however. During deep and rather quick breathing of a gas mixture with a high nitrous oxide concentration, the N20 content rapidly becomes very important in the arterial blood and, so. in the shunted blood, while it begins to increase slowly in the normal venous blood; thus, if simultaneous samples are then obtained from the systemic artery and from the right heart, and if the level in the lallcr is expressed as percentages of the level in the former, the results are very low when there is no shunt: since the arterial eontent is of course lOO/o, a very small shunt gives relatively high percentages in the right heart. The synchronism of the samples, the similitude of the content in the various veins and the large arteriovenous difference justify the interest of the method. The evolution of the arterial and venous N20 levels was analysed in normal patients and in left-to-right shunts; the results have led to important changes in the technics described by other authors: these changes chiefly concern the timing of the sampling (from the 5th to the 15th second of the N20 breathing), the N20 concentration in the gas mixture (N20 79% and 02 21%), the technic of the sampling (emptying of the catheter up to the beginning of the sampling), and finally the “blank” determination (sampling when breathing 02 100%). The normal levels, observed in the right heart and the pulmonary artery of 40 patients, were-1.3 to 6.9% (mean 1.9% SD = 1.7%58 tests); these values, small and very close together, indicate the sensitivity of the technic. 15 patients with a left-lo-right shunt had levels between 10 and 82.9% (mean 40,9%- 16 tesls); the relative increase is quite evident. t tesls, performed in a left ventricle, a left auricle and a pulmonary vein, showed the precision of the method (99.9-100.0 and 100.2%). Finally, the relative errors due to the analysis become negligible as a result of the absolute content in the systemic arteries (2.08 to 19.77 vo!%, mean 11.82-77 tests). According to these characteristics, a venous level higher than 7% of the arterial level is abnormal, and the method should reveal lefl-to-riglil shunts about 5-10% of the systemic output. The iffiiocuity and the practical .simplicity of the method are emphasized, for it requires only a classical right heart catheterization and an usual apparatus. © 1961 S. Karger AG, Basel.SCOPUS: ar.jinfo:eu-repo/semantics/publishe

    CARCINOMA OF THE ISLETS OF LANGERHANS. A TEST FOR HYPERINSULINISM

    No full text
    SCOPUS: ar.jinfo:eu-repo/semantics/publishe

    Methodology of cerebral blood flow measurement

    No full text
    SCOPUS: ar.kinfo:eu-repo/semantics/publishe

    Etude de la circulation pulmonaire dans les affections cardiaques congénitales à shunt gauche-droit

    No full text
    Pulmonary circulation lime is evaluated in patients with heart disease and high pulmonary output by three different methods: the dye dilution technique measures the pulmonary artery—peri pheral artery circulation time and the radiocardiographic method the right ventricle—left ventricle time; the transit time in the capillary segment is estimated from the measurement of the dif fusing capacity of the lung. A significant acceleration of the tran sit time is observed in the pulmonary circulation taken as a whole as well as in the capillary segment. © 1962 S. Karger AG, Basel.SCOPUS: ar.jSCOPUS: ar.jinfo:eu-repo/semantics/publishe

    The krypton-85 method in the detection of pulmonary arterio-venous shunts

    No full text
    Two cases of pulmonary arteriovenous fistulae were studied by the krypton-85 test and by angiocardiograhv. The relative merits of the two methods are discussed. © 1967 S. Karger AG, Basel.SCOPUS: ar.jinfo:eu-repo/semantics/publishe
    corecore