965 research outputs found

    Coronary fly-through or virtual angioscopy using dual-source MDCT data

    Get PDF
    Coronary fly-through or virtual angioscopy (VA) has been studied ever since its invention in 2000. However, application was limited because it requires an optimal computed tomography (CT) scan and time-consuming post-processing. Recent advances in post-processing software facilitate easy construction of VA, but until now image quality was insufficient in most patients. The introduction of dual-source multidetector CT (MDCT) could enable VA in all patients. Twenty patients were scanned using a dual-source MDCT (Definition, Siemens, Forchheim, Germany) using a standard coronary artery protocol. Post-processing was performed on an Aquarius Workstation (TeraRecon, San Mateo, Calif.). Length travelled per major branch was recorded in millimetres, together with the time required in minutes. VA could be performed in every patient for each of the major coronary arteries. The mean (range) length of the automated fly-through was 80 (32–107) mm for the left anterior descending (LAD), 75 (21–116) mm for the left circumflex artery (LCx), and 109 (21–190) mm for the right coronary artery (RCA). Calcifications and stenoses were visualised, as well as most side branches. The mean time required was 3 min for LAD, 2.5 min for LCx, and 2 min for the RCA. Dual-source MDCT allows for high quality visualisation of the coronary arteries in every patient because scanning with this machine is independent of the heart rate. This is clearly shown by the successful VA in all patients. Potential clinical value of VA should be determined in the near future

    Large atom number Bose-Einstein condensate of sodium

    Get PDF
    We describe the setup to create a large Bose-Einstein condensate containing more than 120x10^6 atoms. In the experiment a thermal beam is slowed by a Zeeman slower and captured in a dark-spot magneto-optical trap (MOT). A typical dark-spot MOT in our experiments contains 2.0x10^10 atoms with a temperature of 320 microK and a density of about 1.0x10^11 atoms/cm^3. The sample is spin polarized in a high magnetic field, before the atoms are loaded in the magnetic trap. Spin polarizing in a high magnetic field results in an increase in the transfer efficiency by a factor of 2 compared to experiments without spin polarizing. In the magnetic trap the cloud is cooled to degeneracy in 50 s by evaporative cooling. To suppress the 3-body losses at the end of the evaporation the magnetic trap is decompressed in the axial direction.Comment: 11 pages, 12 figures, submitted to Review Of Scientific Instrument

    Promises of artificial intelligence in neuroradiology:a systematic technographic review

    Get PDF
    Purpose To conduct a systematic review of the possibilities of artificial intelligence (AI) in neuroradiology by performing an objective, systematic assessment of available applications. To analyse the potential impacts of AI applications on the work of neuroradiologists. Methods We identified AI applications offered on the market during the period 2017–2019. We systematically collected and structured information in a relational database and coded for the characteristics of the applications, their functionalities for the radiology workflow and their potential impacts in terms of ‘supporting’, ‘extending’ and ‘replacing’ radiology tasks. Results We identified 37 AI applications in the domain of neuroradiology from 27 vendors, together offering 111 functionalities. The majority of functionalities ‘support’ radiologists, especially for the detection and interpretation of image findings. The second-largest group of functionalities ‘extends’ the possibilities of radiologists by providing quantitative information about pathological findings. A small but noticeable portion of functionalities seek to ‘replace’ certain radiology tasks. Conclusion Artificial intelligence in neuroradiology is not only in the stage of development and testing but also available for clinical practice. The majority of functionalities support radiologists or extend their tasks. None of the applications can replace the entire radiology profession, but a few applications can do so for a limited set of tasks. Scientific validation of the AI products is more limited than the regulatory approval

    Cavity Optomechanical Magnetometer

    Get PDF
    A cavity optomechanical magnetometer is demonstrated where the magnetic field induced expansion of a magnetostrictive material is transduced onto the physical structure of a highly compliant optical microresonator. The resulting motion is read out optically with ultra-high sensitivity. Detecting the magnetostrictive deformation of Terfenol-D with a toroidal whispering gallery mode (TWGM) resonator a peak sensitivity of 400 nT/Hz^.5 was achieved with theoretical modelling predicting that sensitivities of up to 500 fT/Hz^.5 may be possible. This chip-based magnetometer combines high-sensitivity and large dynamic range with small size and room temperature operation

    Crosstalk between salicylic acid signalling and the circadian clock promotes an effective immune response in plants

    Get PDF
    The rotation of Earth creates a cycle of day and night, leading to predictable changes in environmental conditions. The circadian clock synchronizes an organism with these environmental changes and alters their physiology in anticipation. Prediction of the probable timing of pathogen infection enables plants to prime their immune system without wasting resources or sacrificing growth. Here, we explore the relationship between the immune hormone salicylic acid (SA), and the circadian clock in Arabidopsis. We found that SA altered circadian rhythmicity through the SA receptor and master transcriptional coactivator, NPR1. Reciprocally, the circadian clock gates SA-induced transcript levels of NPR1-dependent immune genes. Furthermore, the clock gene CCA1 is essential for SA-induced immunity to the major bacterial plant pathogen Pseudomonas syringae. These results build upon existing studies of the relationship between the circadian clock and SA signalling and how interactions between these systems produce an effective immune response. Understanding how and why the immune response in plants is linked to the circadian clock is crucial in working towards improved crop productivity

    Observation of shock waves in a large Bose-Einstein condensate

    Full text link
    We observe the formation of shock waves in a Bose-Einstein condensate containing a large number of sodium atoms. The shock wave is initiated with a repulsive, blue-detuned light barrier, intersecting the BEC, after which two shock fronts appear. We observe breaking of these waves when the size of these waves approaches the healing length of the condensate. At this time, the wave front splits into two parts and clear fringes appear. The experiment is modeled using an effective 1D Gross-Pitaevskii-like equation and gives excellent quantitative agreement with the experiment, even though matter waves with wavelengths two orders of magnitude smaller than the healing length are present. In these experiments, no significant heating or particle loss is observed.Comment: 7 pages, 7 figure

    Versatile two-dimensional potentials for ultra-cold atoms

    Full text link
    We propose and investigate a technique for generating smooth two-dimensional potentials for ultra-cold atoms based on the rapid scanning of a far-detuned laser beam using a two-dimensional acousto-optical modulator (AOM). We demonstrate the implementation of a feed-forward mechanism for fast and accurate control of the spatial intensity of the laser beam, resulting in improved homogeneity for the atom trap. This technique could be used to generate a smooth toroidal trap that would be useful for static and dynamic experiments on superfluidity and persistent currents with ultra-cold atoms.Comment: 8 pages, 5 figure

    Augmented Reality Visualization for Image-Guided Surgery:A Validation Study Using a Three-Dimensional Printed Phantom

    Get PDF
    Background Oral and maxillofacial surgery currently relies on virtual surgery planning based on image data (CT, MM). Three-dimensional (3D) visualizations are typically used to plan and predict the outcome of complex surgical procedures. To translate the virtual surgical plan to the operating room, it is either converted into physical 3D-printed guides or directly translated using real-time navigation systems. Purpose This study aims to improve the translation of the virtual surgery plan to a surgical procedure, such as oncologic or trauma surgery, in terms of accuracy and speed. Here we report an augmented reality visualization technique for image-guided surgery. It describes how surgeons can visualize and interact with the virtual surgery plan and navigation data while in the operating room. The user friendliness and usability is objectified by a formal user study that compared our augmented reality assisted technique to the gold standard setup of a perioperative navigation system (Brainlab). Moreover, accuracy of typical navigation tasks as reaching landmarks and following trajectories is compared. Results Overall completion time of navigation tasks was 1.71 times faster using augmented reality (P = .034). Accuracy improved significantly using augmented reality (P < .001), for reaching physical landmarks a less strong correlation was found (P = .087). Although the participants were relatively unfamiliar with VR/AR (rated 2.25/5) and gesture-based interaction (rated 2/5), they reported that navigation tasks become easier to perform using augmented reality (difficulty Brainlab rated 3.25/5, HoloLens 2.4/5). Conclusion The proposed workflow can be used in a wide range of image-guided surgery procedures as an addition to existing verified image guidance systems. Results of this user study imply that our technique enables typical navigation tasks to be performed faster and more accurately compared to the current gold standard. In addition, qualitative feedback on our augmented reality assisted technique was more positive compared to the standard setup. (C) 2021 The Author. Published by Elsevier Inc. on behalf of The American Association of Oral and Maxillofacial Surgeons

    Robust and Accurate Mandible Segmentation on Dental CBCT Scans Affected by Metal Artifacts Using a Prior Shape Model

    Get PDF
    Accurate mandible segmentation is significant in the field of maxillofacial surgery to guide clinical diagnosis and treatment and develop appropriate surgical plans. In particular, cone-beam computed tomography (CBCT) images with metal parts, such as those used in oral and maxillofacial surgery (OMFS), often have susceptibilities when metal artifacts are present such as weak and blurred boundaries caused by a high-attenuation material and a low radiation dose in image acquisition. To overcome this problem, this paper proposes a novel deep learning-based approach (SASeg) for automated mandible segmentation that perceives overall mandible anatomical knowledge. SASeg utilizes a prior shape feature extractor (PSFE) module based on a mean mandible shape, and recurrent connections maintain the continuity structure of the mandible. The effectiveness of the proposed network is substantiated on a dental CBCT dataset from orthodontic treatment containing 59 patients. The experiments show that the proposed SASeg can be easily used to improve the prediction accuracy in a dental CBCT dataset corrupted by metal artifacts. In addition, the experimental results on the PDDCA dataset demonstrate that, compared with the state-of-the-art mandible segmentation models, our proposed SASeg can achieve better segmentation performance
    • …
    corecore