27 research outputs found

    Binocular visual function after staged implantation of extended-depth-of-focus intraocular lens targeting emmetropia and -0.5 diopter: A prospective comparison

    Get PDF
    The prospective comparative case series aimed to evaluate the binocular uncorrected visual acuities (BUCVAs) after staged implantations of extended-depth-of-focus intraocular lenses (EDOF IOLs) targeting emmetropia and -0.5 diopter (D). Diffractive EDOF IOLs with an add power of +1.75 D were implanted in the first eyes targeting emmetropia or -0.5 D according to the patients' preferences, then the targets for the second eyes were determined 1 week or longer after the implantation. IOL powers were determined with the SRK/T formula. Consequently, the subjects were divided into 3 groups: those with emmetropia targeted bilaterally (group EE, 22 patients), those with -0.5 D targeted bilaterally (group MM, 21 patients), and those with monovision of emmetropia and -0.5 D (group EM, 21 patients). Manifest refraction spherical equivalent (MRSE), BUCVA from 0.3 to 5 meters, spectacle use, and questionnaire regarding photic symptoms and patient satisfaction were assessed 3 months postoperatively. No significant differences were seen in the mean BUCVAs at any distance (P > 0.23), spectacle use (P = 0.13), or photic symptoms and patient satisfaction (P>0.65). When the EE and MM groups were assigned based on the MRSE, the EE group was better at 5 m (P = 0.005) while the MM group at 0.5 m (P = 0.031). The effect of different targeted refractions was not identified due to insufficient accuracy in the use of the SRK/T power calculation

    Efficacy of Femtosecond Laser-Assisted Capsulotomy: Experimental Evaluation Using the Zonular Dehiscence Model

    Get PDF

    Tono-Pen XL tonometry during application of a suction ring in rabbits

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The purpose of this study is to evaluate the use of Tono-Pen XL in measuring IOP during the application of a suction ring in rabbit eyes with manometrically controlled IOP.</p> <p>Methods</p> <p>Tono-Pen XL was calibrated against direct manometry in 10 rabbit eyes. A suction ring was then applied in 4 rabbit eyes and the IOP was determined manometrically during suction ring application at 350 mmHg vacuum pressure. Finally, in 6 catheterized rabbit eyes the IOP was measured with Tono-Pen XL during suction ring application at suction vacuum from 350 to 650 mmHg, while keeping actual IOP stable at 30 mmHg and 60 mmHg.</p> <p>Results</p> <p>Linear regression analysis revealed that the Tono-pen XL was reliable for IOPs between 10 and 70 mmHg (R<sup>2 </sup>= 0.9855). Direct manometry during suction ring application showed no statistically significant variation of Tono-Pen XL readings when the incanulation manometry intraocular pressure changed from 30 mmHg to 60 mmHg and no statistically significant correlation between suction vacuum and IOP measurements.</p> <p>Conclusion</p> <p>Tono-Pen XL measurements are unreliable during the application of a suction ring on living rabbit eyes even when the actual IOP is forced to be within the validated range of Tono-Pen XL measurements. This inaccuracy is probably related to altered corneal and scleral geometry and stress.</p

    Viscoat versus Visthesia during phacoemulsification cataract surgery: corneal and foveal changes

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Ophthalmic viscosurgical devices (OVDs) are widely used in phacoemulsification cataract surgery to maintain adequate intraocular space, stabilize ocular tissue during the operation and decrease the possible damage of the corneal endothelium. Our study has the purpose to compare the corneal and foveal changes of Viscoat and Visthesia in patients undergoing uneventful phacoemulsification cataract surgery.</p> <p>Methods</p> <p>Participants in our study were 77 consecutive patients, who were randomized into two groups based on type of OVD used during phacoemulsification: Viscoat or Visthesia. All patients underwent a complete ophthalmological examination i.e., measurement of best corrected visual acuity (BCVA) by means of Snellen charts, intraocular pressure examination by Goldmann tonometry, slit lamp examination, fundus examination, optical coherence tomography, specular microscopy and ultrasound pachymetry preoperatively and at three time points postoperatively (day 3, 15, 28 postoperatively). The differences in baseline characteristics, as well as in outcomes between the two groups were compared by Mann-Whitney-Wilcoxon test and Student's t-test, as appropriate.</p> <p>Results</p> <p>Intraoperatively, there was no statistically significant difference in the duration of the ultrasound application between the two groups, while Viscoat group needed more time for the operation performance. It is also worthy to mention that Visthesia group exhibited less intense pain than patients in Viscoat group. Postoperatively, there was a statistically significant difference in central corneal thickness, endothelial cell count and macular thickness between the two groups, but BCVA (logMAR) did not differ between the two groups.</p> <p>Conclusions</p> <p>Our study suggests that Viscoat is more safe and protective for the corneal endothelium during uneventful phacoemulsification cataract surgery, while Visthesia is in superior position regarding intraoperative pain. Patients of both groups acquired excellent visual acuity postoperative. Finally, this is the first study comparing OVDs in terms of macular thickness, finding that Visthesia cause a greater increase in macular thickness postoperatively than Viscoat, although it reaches normal ranges in both groups.</p

    Intact corneal epithelium is essential for the prevention of stromal haze after laser assisted in situ keratomileusis

    No full text
    AIMS—To determine the effect of intact corneal epithelium on stromal haze and myofibroblast cell formation after excimer laser surgery.
METHODS—Denuded epithelium alone, photorefractive keratectomy (PRK), laser in situ keratomileusis (LASIK), or LASIK with denuded epithelium was performed in rabbit eyes. Postoperative anterior stromal haze was assessed employing a standard scale. Immunohistochemical methods were used to detect alpha smooth muscle actin (α-SMA), a marker for myofibroblastic cells, and type III collagen in subepithelial corneal tissue.
RESULTS—Three weeks after surgery, the presence of α-SMA positive long extended and spindle-shaped stromal cells, and synthesis of type III collagen were observed in the subepithelial stromal layer corresponding to corneal haze in PRK and LASIK with denuded epithelium, but not in denuded epithelium alone and LASIK.
CONCLUSION—The intact corneal epithelium may play an important part curbing subepithelial haze and differentiation of myofibroblasts in corneal wound healing.


    Clinical Results of a Trifocal Toric Intraocular Lens Using the Holladay Total Surgically Induced Astigmatism Formula for Correcting Low Corneal Astigmatism in Japanese Patients

    No full text
    Hiroko Bissen-Miyajima,1 Yuka Ota,1 Saori Yaguchi,1 Kunihiko Nakamura,1 Noriyuki Sasaki2 1Department of Ophthalmology, Tokyo Dental College Suidobashi Hospital, Tokyo, Japan; 2Alcon Japan Ltd, Tokyo, JapanCorrespondence: Hiroko Bissen-Miyajima, Department of Ophthalmology, Tokyo Dental College, Suidobashi Hospital, Kandamisaki‑cho 2‑9‑18, Chiyoda‑ku, Tokyo, 101‑0061, Japan, Tel +81-3-5275-1856, Email [email protected]: To evaluate the effectiveness and safety of the AcrySof IQ PanOptix toric intraocular lens (IOL) with cylinder power of 1.0 D (TFNT20) in a Japanese population with low corneal astigmatism and compare with historical control data for nontoric IOLs.Setting: Tokyo Dental College Suidobashi Hospital, Tokyo, Japan.Design: Prospective, single-center study.Methods: Patients ≥ 20 years old received TFNT20 IOL in at least 1 eye based on Alcon Toric calculator (Holladay Total surgically induced astigmatism). Effectiveness endpoints included the percentage of eyes with refractive cylinder ≤ 0.25 D at 30– 60 days after surgery, which was compared with a historical control threshold rate of 29.2% for nontoric IOLs and refractive cylinder ≤ 0.50 D. Monocular uncorrected distance visual acuity (UDVA; 5 m), uncorrected intermediate visual acuity (UIVA; 60 cm), uncorrected near visual acuity (UNVA; 40 cm), and adverse events were evaluated.Results: Of 41 eyes implanted with TFNT20 IOLs, 37 eyes (90%) achieved refractive cylinder ≤ 0.25 D at 30– 60 days after surgery, demonstrating the superiority of TFNT20 compared with historical data (P< 0.0001). Refractive cylinder of ≤ 0.50 D was achieved by 41 eyes (100%). At 30– 60 days, mean ± SD monocular CDVA was − 0.15 ± 0.07 logMAR, UDVA was − 0.09 ± 0.09 logMAR, UIVA was − 0.00 ± 0.07 logMAR, and UNVA was 0.03 ± 0.07 logMAR. Six eyes (15%) had elevated postoperative intraocular pressure, which returned to normal and was not device-related.Conclusion: TFNT20 IOLs successfully reduced postoperative refractive cylinder and provided good distance, intermediate, and near uncorrected VAs in Japanese patients with low corneal astigmatism.Keywords: trifocal IOL, toric IOL, low corneal astigmatism, toric calculator, visual acuit
    corecore