Local spread patterns of malignant tumors follow permissive tissue territories, i.e., cancer fields, as shown for cervical and vulvar carcinoma. The cancer fields are associated in reverse order to the mature derivatives of the morphogenetic fields instrumental in the stepwise development of the tissue from which the tumor arose. This suggests that cancer progression may be linked to morphogenesis by inversion of the cellular bauplan sequence. Successive attractor transitions caused by proliferation-associated constraints of topobiological information processing are proposed for both morphogenesis and cancer. In morphogenesis these transitions sequentially activate bauplans with increasing complexity at decreasing plasticity restricting the permissive territories of the progenitor cell populations. Somatic mutations leading to cell proliferation in domains normally reserved for differentiation trigger the inverse cascade of bauplan changes that increase topobiological plasticity at decreased complexity and stepwise enlarge the permissive territory of neoplastic cells consistent with the clinical manifestations of cancer. The order provided by the sequence of attractor transitions and the defined topography of the permissive territories can be exploited for more accurate tumor staging and for locoregional tumor treatment either by surgery or radiotherapy with higher curative potential
Nutzung von Qualitätsreserven in elektrischen Verteilnetzen
Für eine kosteneffiziente Auslegung und einen stabilen Betrieb der stark beanspruchten Verteilnetze der Zukunft ist das Verständnis des Einflusses verschiedener Netzvarianten und Belastungszustände auf die Spannungsqualität äusserst wichtig. Hierfür werden mit Messkampagnen in verschiedenen Niederspannungsnetzen die Qualitätsreserven analysiert und ein generisches Überwachungskonzept formuliert
Stabiles Netz dank dezentralen Batteriespeichern
Die Anzahl an Photovoltaikanlagen mit Batteriespeicher nimmt stetig zu. Mit modernen Betriebsstrategien könnten diese Anlagen nicht nur den Eigengebrauch von selbst produziertem Strom erhöhen, sondern auch zur Netzstabilität beitragen. Forschende der Berner Fachhochschule BFH haben über Simulationen den potenziellen Nutzen für das Verteilnetz untersucht
Qualité de la tension dans la planification du réseau
L’évolution de la qualité de la tension dans le réseau de distribution est déterminée par le type, le nombre, la puissance et l’utilisation des appareils et installations ainsi que par le dimensionnement du réseau. Dans le projet OptiQ, des aides et recommandations ont été développées afin de permettre la prise en compte de la qualité de la tension lors de la planification du réseau cible
Harmonic analysis and mitigation in distribution grids with high penetration of power inverters
Inverters of large heat pumps in an urban low voltage grid generate current harmonics and cause consequently significant variations of the respective voltage harmonics. The voltage level at each grid point is not only influenced by the operation of such inverters, but higher harmonic voltage amplitudes can be expected, caused by the sum of all loads in the grid. The paper provides a comprehensive harmonic analysis of a typical urban distribution grid including heat pumps and presents insights on the variations and impact on the voltage profile of the 15th harmonic currents. An active harmonic filter was installed to enhance the power quality, by compensating the harmonic currents and by improving the voltage profile at grid points close-by the heat pumps
Energiespeicher im Stromnetz
In der Diskussion über den Einsatz von Energiespeichern wie zum Beispiel Batterien stehen die Optimierung von Energieflüssen und die Kosten im Vordergrund. Dass beim Betrieb von immer mehr leistungsstarken Anlagen Netzrückwirkungen entstehen, welche bereits heute zu kritischen Betriebszuständen des Stromnetzes führen können, wird gerne vergessen
Stockage d’énergie dans le réseau électrique
Lors de l’intégration de dispositifs de stockage d’énergie tels que les batteries, l’accent est mis sur l’optimisation des flux et des coûts énergétiques. Mais on oublie souvent que le fonctionnement de ces systèmes de plus en plus puissants provoque des perturbations pouvant conduire à des états de fonctionnement critiques du réseau électrique
Wie viel PhotoÂvoltaik verÂträgt das Verteilnetz?
FĂĽr eine Analyse wurden in einem Trafokreis fĂĽnf Sensoren in VerteilÂnetzÂkabinen und beim Trafo installiert und diverse RegeÂlungen getestet. Das Resultat: ZusätzÂliche RegeÂlungen ermögÂlichen zwar mehr PV im Netz, aber der ProjekÂtierungs-, InstallaÂtions- und BetriebsÂaufwand ist hoch. Andere MassÂnahmen können sinnvoller sein
QualitätsÂreserven in Verteilnetzen
FĂĽr eine kostenÂeffiziente AusÂlegung und einen stabilen Betrieb der stark beanÂspruchten kĂĽnfÂtigen VerteilÂnetze ist es essenÂziell, den Einfluss verschieÂdener NetzÂvarianÂten und BelastungsÂzustände auf die SpanÂnungsÂqualität zu verstehen. HierfĂĽr werden die QualitätsÂreserven mit MessÂkamÂpagnen analysiert und ein generiÂsches ĂśberÂwachungsÂkonzept formuliert
Survey of network impedance in the frequency range 2-9 kHz in public low voltage networks in AT/CH/CZ/GE
Setting realistic emission limits for distorting customer installations is a crucial requirement for a reliable and disturbance-free operation of public distribution networks. Therefore only an adequate share of the total allowable voltage distortion (compatibility level) has to be allocated to each customer installation. This allowable contribution of a single customer installation is usually small and difficult to assess. Hence, nowadays most standards and guidelines translate the allocated voltage distortion in a respective current distortion by using the network impedance at the considered frequency. As frequency-dependent network impedance is usually not known during the planning process, assumptions are required, which have to be realistic and not too conservative. This applies in particular to frequencies above 2 kHz, where the usually used extrapolation based on short circuit impedance can be very conservative due to the increasing impact of connected customer equipment on the network impedance. Based on a comprehensive measurement campaign in four different countries this paper identifies typical ranges of the frequency-dependent network impedance in the frequency range 2-9kHz. It analyses the impact of short circuit power and proposes a simplified impedance estimation, which can be used to calculate realistic current emission limits in the planning stage
- …