    Accuracy of out-of-field dose calculation of tomotherapy and cyberknife treatment planning systems: A dosimetric study.

    No full text
    PURPOSE: Late toxicities such as second cancer induction become more important as treatment outcome improves. Often the dose distribution calculated with a commercial treatment planning system (TPS) is used to estimate radiation carcinogenesis for the radiotherapy patient. However, for locations beyond the treatment field borders, the accuracy is not well known. The aim of this study was to perform detailed out-of-field-measurements for a typical radiotherapy treatment plan administered with a Cyberknife and a Tomotherapy machine and to compare the measurements to the predictions of the TPS. MATERIALS AND METHODS: Individually calibrated thermoluminescent dosimeters were used to measure absorbed dose in an anthropomorphic phantom at 184 locations. The measured dose distributions from 6 MV intensity-modulated treatment beams for CyberKnife and TomoTherapy machines were compared to the dose calculations from the TPS. RESULTS: The TPS are underestimating the dose far away from the target volume. Quantitatively the Cyberknife underestimates the dose at 40cm from the PTV border by a factor of 60, the Tomotherapy TPS by a factor of two. If a 50% dose uncertainty is accepted, the Cyberknife TPS can predict doses down to approximately 10 mGy/treatment Gy, the Tomotherapy-TPS down to 0.75 mGy/treatment Gy. The Cyberknife TPS can then be used up to 10cm from the PTV border the Tomotherapy up to 35cm. CONCLUSIONS: We determined that the Cyberknife and Tomotherapy TPS underestimate substantially the doses far away from the treated volume. It is recommended not to use out-of-field doses from the Cyberknife TPS for applications like modeling of second cancer induction. The Tomotherapy TPS can be used up to 35cm from the PTV border (for a 390 cm(3) large PTV)

    Optimized workflow to minimise intra-fractional motion during stereotactic body radiotherapy of spinal metastases

    No full text
    Background and purpose: This study evaluated translational and rotational intra-fractional patient movement during spinal stereotactic body radiotherapy (SBRT) using 6D positioning based on 3D cone beam computerized tomography (CBCT) and stereoscopic kilovoltage imaging (ExacTrac). The aim was to determine whether additional intra-fractional image verification reduced intra-fractional motion without significantly prolonging treatment time, whilst maintaining acceptable imaging related dose. Materials and methods: A retrospective analysis of 38 patients with 41 primary tumour volumes treated with SBRT between September 2018 and May 2021 was performed. Three different image-guided radiotherapy (IGRT) workflows were assessed. The translational and rotational positioning errors for the different imaging workflows, 3D translational vectors and estimates of imaging dose delivered for the different imaging workflows were evaluated. Results: As the frequency of intra-fractional imaging increased from workflow 1 to 3, the mean intra-fraction 3D translational vector improved from 0.91 mm (±0.52 mm), to 0.64 (±0.34 mm). 85 %, 83 % and 97 % of images were within a tolerance of 1 mm/1° for workflows 1, 2 and 3 respectively, based on post treatment CBCT images. The average treatment time for workflow 3 was 13 min, as compared to 12 min for workflows 1 and 2. The effective dose per treatment for IGRT workflows 1, 2 and 3 measured 0.6 mSv, 0.95 mSv and 1.8 mSv respectively. Conclusion: The study demonstrated that the use of additional intra-fractional stereoscopic kilovoltage image-guidance during spinal SBRT, reduced the number of measurements deemed “out of tolerance” and treatment delivery could be optimized within a standard treatment timeslot without applying substantial additional radiation dose
    corecore