143 research outputs found

    Effect of Dietary Protein Level and Origin on the Redox Status in the Digestive Tract of Mice

    Get PDF
    The present study was undertaken to evaluate the effects of high protein (soybean protein or casein) on the balance between production of free radicals and antioxidant level in digestive organs of mice. For this purpose, male (C57BL/6J) mice were adapted to experimental diets containing soybean protein or casein with 20% (normal protein diets, NPDs) or 60% (high protein diets, HPDs), and HPDs supplemented with 0.06g/kg cysteamine. After two weeks of feeding, oxidative and antioxidative parameters in duodenum, liver and pancreas were measured. The results show that ingestion of high protein markedly increased contents of superoxide anion and malondialdehyde (MDA), decreased activities of superoxide dismutase (SOD), glutathione peroxidase (GSH-Px), catalase (CAT) and Na+ K+-ATPase, and content of reduced glutathione (GSH) in digestive organs of mice (P<0.05). Levels of oxidative parameters were lower and antioxidant capacity of both enzyme and non-enzyme was higher in mice fed with soybean protein than those fed with casein. In groups fed HPDs supplemented with cysteamine, oxidative stress was mitigated. However, oxidative parameter levels were still higher than those of NPD-fed groups. The present study indicates that ingestion of high protein diets could result in an imbalance between oxidant and antioxidant, and thus induce oxidative stress in digestive organs of mice. The oxidative damage was smaller in mice fed with high level of soy protein in comparison with casein

    Synthesis of Boron Nitride Nanotubes by Self-Propagation High-Temperature Synthesis and Annealing Method

    Get PDF
    High-quality boron nitride nanotubes were synthesized by annealing porous precursor in flowing NH3 gas at 1150°C. The porous precursor B18Ca2(MgO)9 was produced by self-propagation high-temperature synthesis (SHS) method using Mg, B2O3, and CaB6 as the starting materials, which played an important role in synthesis of BN nanotubes in large quantities. Samples were characterized by SEM, TEM, EDX, HRTEM, X-ray powder diffraction (XRD), Raman, and Fourier transform infrared (FTIR) spectroscopy. The as-synthesized BN nanotubes have an average diameter of about 150 nm with a wall/diameter ratio of 2/3. Mean length of the BN nanotubes was more than 10 μm. The effects of temperature, time, and the possible mechanism of the growth of the BN nanotubes were also discussed

    Novel Roaming and Stationary Tethered Aerial Robots for Continuous Mobile Missions in Nuclear Power Plants

    Get PDF
    AbstractIn this paper, new tethered aerial robots including roaming tethered aerial robots (RTARs) for radioactive material sampling and stationary tethered aerial robots (STARs) for environment monitoring are proposed to meet extremely-long-endurance missions of nuclear power plants. The flight of the proposed tethered aerial robots may last for a few days or even a few months as long as the tethered cable provides continuous power. A high voltage AC or DC power system was newly adopted to reduce the mass of the tethered cable. The RTAR uses a tethered cable spooled from the aerial robot and an aerial tension control system. The aerial tension control system provides the appropriate tension to the tethered cable, which is accordingly laid down on the ground as the RTAR roams. The STAR includes a tethered cable spooled from the ground and a ground tension control system, which enables the STAR to reach high altitudes. Prototypes of the RTAR and STAR were designed and successfully demonstrated in outdoor environments, where the load power, power type, operating frequency, and flight attitude of the RTAR and STAR were: 180 W, AC 100 kHz, and 20 m; and 300 W, AC or DC 100 kHz, and 80 m, respectively

    Friedel Oscillation-Induced Energy Gap Manifested as Transport Asymmetry at Monolayer-Bilayer Graphene Boundaries

    Full text link
    We show that Friedel charge oscillation near an interface opens a gap at the Fermi energy for electrons with wave vectors perpendicular to the interface. If the Friedel gaps on two sides of the interface are different, a nonequlibrium effect - shifting of these gaps under bias - leads to asymmetric transport upon reversing the bias polarity. The predicted transport asymmetry is revealed by scanning tunneling potentiometry at monolayer-bilayer interfaces in epitaxial graphene on SiC (0001). This intriguing interfacial transport behavior opens a new avenue towards novel quantum functions such as quantum switching.Comment: accepted for publication in PR

    Immunoglobulin G Locus Events in Soft Tissue Sarcoma Cell Lines

    Get PDF
    Recently immunoglobulins (Igs) have been found to be expressed by cells other than B lymphocytes, including various human carcinoma cells. Sarcomas are derived from mesenchyme, and the knowledge about the occurrence of Ig production in sarcoma cells is very limited. Here we investigated the phenomenon of immunoglobulin G (IgG) expression and its molecular basis in 3 sarcoma cell lines. The mRNA transcripts of IgG heavy chain and kappa light chain were detected by RT-PCR. In addition, the expression of IgG proteins was confirmed by Western blot and immunofluorescence. Immuno-electron microscopy localized IgG to the cell membrane and rough endoplasmic reticulum. The essential enzymes required for gene rearrangement and class switch recombination, and IgG germ-line transcripts were also identified in these sarcoma cells. Chromatin immunoprecipitation results demonstrated histone H3 acetylation of both the recombination activating gene and Ig heavy chain regulatory elements. Collectively, these results confirmed IgG expression in sarcoma cells, the mechanism of which is very similar to that regulating IgG expression in B lymphocytes

    Recursive Dynamic Algorithm of Open-Chain Multibody System

    Get PDF
    Open-chain multibody systems have been extensively studied because of their widespread application. Based on the structural characteristics of such a system, the relationship between its hinged bodies was transformed into recursive constraint relationships among the position, velocity, and acceleration of the bodies. The recursive relationships were used along with the Huston-Kane method to select the appropriate generalized coordinates and determine the partial velocity of each body and to develop an algorithm of the entire system. The algorithm was experimentally validated; it has concise steps and low susceptibility to error. Further, the algorithm can readily solve and analyze open-chain multibody systems

    Retroperitoneal Laparoscopic Ureterolithotomy for Proximal Ureteral Calculi in Selected Patients

    Get PDF
    Objectives. To summarize our experience of retroperitoneal laparoscopic ureterolithotomy for ureteral calculi and evaluate the safety and efficiency of this procedure. Methods. We conducted a retrospective analysis of 197 patients with proximal ureteral calculi who accepted retroperitoneal laparoscopic ureterolithotomy from June 2005 to June 2014. Results. All procedures were performed successfully and the mean operating time and estimated blood loss were 87 min and 64 mL. The clearance rate was 98.5% and the rates of urine leak and ureteral stricture were 2.5% and 1.0%. Conclusions. Retroperitoneal laparoscopic ureterolithotomy is a safe and effective procedure for patients with complex stones or anatomic abnormalities, and, with experience of high volume series, it is also a reasonable choice as the primary treatment for such selected patients

    Robust estimation of bacterial cell count from optical density

    Get PDF
    Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals &lt;1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data
    • …
    corecore