11 research outputs found

    Acute and Subacute Stent Thrombosis in a Patient With Clopidogrel Resistance: A Case Report

    Get PDF
    Drug-eluting stents (DES) are considered the treatment of choice for most patients with obstructive coronary artery disease when percutaneous intervention (PCI) is feasible. However, stent thrombosis seems to occur more frequently with DES and occasionally is associated with resistance to anti-platelet drugs. We have experienced a case of recurrent stent thrombosis in a patient with clopidogrel resistance. A 63-year-old female patient suffered from acute myocardial infarction and underwent successful PCI of the left anterior descending coronary artery (LAD) with two DESs. She was found to be hyporesponsive to clopidogrel and was treated with triple anti-platelet therapy (aspirin 100 mg, clopidogrel 75 mg, and cilostazol 200 mg daily). Three days after discharge, she developed chest pain and was again taken to the cardiac catheterization laboratory, where coronary angiography (CAG) showed total occlusion of the mid-LAD where the stent had been placed. After intravenous administration of a glycoprotein IIb/IIIa inhibitor, balloon angioplasty was performed, resulting in Thrombolysis In Myocardial Infarction (TIMI) III antegrade flow. The next day, however, she complained of severe chest pain, and the electrocardiogram showed marked ST-segment elevation in V1-V6, I, and aVL with complete right bundle branch block. Emergent CAG revealed total occlusion of the proximal LAD due to stent thrombosis. She was successfully treated with balloon angioplasty and was discharged with triple anti-platelet therapy

    Reinforced Concrete Slabs Strengthened with Carbon Textile Grid and Cementitious Grout

    No full text
    A textile reinforced concrete (TRC) system has been widely used for repair and strengthening of deteriorated reinforced concrete (RC) structures. This paper proposes an accelerated on-site installation method of a TRC system by grouting to strengthen deteriorated RC structures. Four RC slabs were strengthened with one ply of carbon textile grid and 20 mm-thick cementitious grout. The TRC strengthened slab specimens were tested under flexure and the test results were compared with those of an unstrengthened specimen and theoretical solutions. Furthermore, the TRC strengthened specimens experienced longer plastic deformation after steel yield than the unstrengthened specimen. The TRC strengthened specimens exhibited many fine cracks and finally failed by rupture of the textile. Therefore, TRC system with the proposed installation method can effectively be used for strengthening of deteriorated RC structural elements. The theoretically computed steel yield and ultimate loads overestimate the test data by 11% and 5%, respectively

    Reinforced Concrete Slabs Strengthened with Lap-Spliced Carbon TRC System

    No full text
    Construction with precast or prefabricated elements requires the connecting of structural joints. This study presents an accelerated construction method to strengthen reinforced concrete (RC) slab-type elements in flexure using precast lap-spliced textile-reinforced concrete (TRC) panels. The objectives of this study are to identify the tensile behavior of a TRC system with lap-spliced textile, and to experimentally validate the performance of the proposed connecting method by flexural failure test for the concrete slabs strengthened by TRC panels with lap-spliced textile. Twenty-one coupon specimens were tested in tension with two different matrix systems and three different lap splice lengths. The influence of the lap splice length and matrix properties on the tensile performance of the TRC system was significant. Five full-scale RC slabs were strengthened by the precast TRC panels with and without the lap splice, and was tested in flexure. The results of the failure test for the strengthened specimens showed that the ultimate load of the strengthened specimen with the TRC panel increased by a maximum of 24%, compared to that of the unstrengthened specimen. Moreover, the failure-tested specimens were re-strengthened by a new TRC panel system and tested again in flexure. The objective of the re-strengthening of the damaged RC slabs by the TRC panel is to investigate whether the yielded steel reinforcement can be replaced by the TRC panel. The initial cracking load and the stiffness of the re-strengthened specimens were significantly increased by re-strengthening

    Underwater Repair of Concrete Elements with TRC Grouting System

    No full text
    The repair of underwater concrete structures is usually difficult work, requiring specialized materials and installation systems. This paper presents a carbon-textile-reinforced concrete (TRC) grouting system for underwater repair of concrete structures. One multi-purpose grout and two types of underwater grouts were considered in this study, and the bond performance between the substrate and grout was evaluated by a bi-surface shear test with cubic specimens. The bond strength of the repair material is greatly affected by the casting and curing conditions. When the multi-purpose grout is used, the average bond strength of the specimens cast and cured in dry conditions is only 22% of the specimens cast and cured in underwater conditions. On the other hand, the maximum difference in bond strength is, at most, 15.8% when non-dispersive, anti-washout grouts are used. Two types of installation methods were proposed and four full-scale RC slab specimens were repaired with the TRC grouting method, two for each installation method. Regardless of the installation method, the load levels that causes concrete cracking, steel yield, and the failure of specimens repaired with the TRC grouting system are at least 37.5%, 16.6%, and 21.7% greater than those of the unrepaired specimen, respectively. The test results further indicate that the influence of the grouting materials on the ultimate load-carrying capacity of the specimens repaired with the TRC grouting system is insignificant, and the maximum difference is, at most, 4%

    Improvement in Predicting the Post-Cracking Tensile Behavior of Ultra-High Performance Cementitious Composites Based on Fiber Orientation Distribution

    No full text
    In this paper, the post-cracking tensile behavior of Ultra-High Performance Cementitious Composites (UHPCC) was studied and an improved analytical model to predict the behavior depending on the fiber orientation distribution was proposed. Two different casting methods were adopted to estimate the influence of the casting method on the tensile behavior. The direct tensile test results showed that the post-cracking tensile behavior was considerably dependent on the casting method. The influence of the casting method was quantified by image analysis of the fiber distribution. The fiber orientation distribution obtained by image analysis may sometimes include considerable error according to the image resolution, which may cause inaccuracy when predicting the post-cracking tensile behavior based on the fiber orientation distribution. To overcome this dependency, the tensile bridging behavior by the fibers in UHPCC was simulated considering the obtained fiber orientation distribution as well as the number of fibers detected. The post-cracking behavior was then simulated by combining the bridging behavior and tension softening behavior of the matrix. The approach adopted in this study to simulate the post-cracking behavior of UHPCC showed good agreement with the experimental results

    EFFECT OF THE CURING METHOD ON THE COMPRESSIVE STRENGTH OF UHSCC

    No full text
    ABSTRACT This paper intends to investigate the effects of the curing method on the compressive strength of the developed UHSCC. In view of the results, wet curing during one day followed by 2 to 3 days of steam curing at 90°C seems to be advisable and leads to the possibility to obtain a compressive strength of approximately 200MPa at age 7 days. We carried out XRD and NMR analysis to explain the signification improvement of strength at high temperature. The extreme densification of the structure of the hardened cement paste accelerated by the pozzolanic reaction caused the increase of strength

    Modeling the Effect of Alternative Cementitious Binders in Ultra-High-Performance Concrete

    No full text
    The use of alternative cementitious binders is necessary for producing sustainable concrete. Herein, we study the effect of using alternative cementitious binders in ultra-high-performance concrete (UPHC) by calculating the phase assemblages of UHPC in which Portland cement is replaced with calcium aluminate cement, calcium sulfoaluminate cement, metakaolin or blast furnace slag. The calculation result shows that replacing Portland cement with calcium aluminate cement or calcium sulfoaluminate cement reduces the volume of C-S-H but increases the overall solid volume due to the formation of other phases, such as strätlingite or ettringite. The modeling result predicts that using calcium aluminate cement or calcium sulfoaluminate cement may require more water than it would for plain UHPC, while a similar or lower amount of water is needed for chemical reactions when using blast furnace slag or metakaolin

    AN EXPERIMENTAL INVESTIGATION ON MINIMUM COMPRESSIVE STRENGTH OF EARLY AGE CONCRETE TO PREVENT FROST DAMAGE FOR NUCLEAR POWER PLANT STRUCTURES IN COLD CLIMATES

    Get PDF
    Concrete undergoing early frost damage in cold weather will experience significant loss of not only strength, but also of permeability and durability. Accordingly, concrete codes like ACI-306R prescribe a minimum compressive strength and duration of curing to prevent frost damage at an early age and secure the quality of concrete. Such minimum compressive strength and duration of curing are mostly defined based on the strength development of concrete. However, concrete subjected to frost damage at early age may not show a consistent relationship between its strength and durability. Especially, since durability of concrete is of utmost importance in nuclear power plant structures, this relationship should be imperatively clarified. Therefore, this study verifies the feasibility of the minimum compressive strength specified in the codes like ACI-306R by evaluating the strength development and the durability preventing the frost damage of early age concrete for nuclear power plant. The results indicate that the value of 5 MPa specified by the concrete standards like ACI-306R as the minimum compressive strength to prevent the early frost damage is reasonable in terms of the strength development, but seems to be inappropriate in the viewpoint of the resistance to chloride ion penetration and freeze-thaw. Consequently, it is recommended to propose a minimum compressive strength preventing early frost damage in terms of not only the strength development, but also in terms of the durability to secure the quality of concrete for nuclear power plants in cold climates
    corecore