93 research outputs found
Recommended from our members
Deep x-ray lithography for micromechanics
Extensions of the German LIGA process have brought about fabrication capability suitable for cost effective production of precision engineered components. The process attributes allow fabrication of mechanical components which are not capable of being made via conventional subtractive machining methods. Two process improvements have been responsible for this extended capability which involve the areas of thick photoresist application and planarization via precision lapping. Application of low-stress x-ray photoresist has been achieved using room temperature solvent bonding of a preformed photoresist sheet. Precision diamond lapping and polishing has provided a flexible process for the planarization of a wide variety of electroplated metals in the presence of photoresist. Exposure results from the 2.5 GeV National Synchrotron Light Source storage ring at Brookhaven National Laboratory have shown that structural heights of several millimeter and above are possible. The process capabilities are also well suited for microactuator fabrication. Linear and rotational magnetic microactuators have been constructed which use coil winding technology with LIGA fabricated coil forms. Actuator output forces of 1 milliNewton have been obtained with power dissipation on the order of milliWatts. A rotational microdynamometer system which is capable of measuring torque-speed data is also discussed
Spontaneous mechanical oscillation of a DC driven single crystal
There is a large interest to decrease the size of mechanical oscillators
since this can lead to miniaturization of timing and frequency referencing
devices, but also because of the potential of small mechanical oscillators as
extremely sensitive sensors. Here we show that a single crystal silicon
resonator structure spontaneously starts to oscillate when driven by a constant
direct current (DC). The mechanical oscillation is sustained by an
electrothermomechanical feedback effect in a nanobeam, which operates as a
mechanical displacement amplifier. The displacement of the resonator mass is
amplified, because it modulates the resistive heating power in the nanobeam via
the piezoresistive effect, which results in a temperature variation that causes
a thermal expansion feedback-force from the nanobeam on the resonator mass.
This self-amplification effect can occur in almost any conducting material, but
is particularly effective when the current density and mechanical stress are
concentrated in beams of nano-scale dimensions
Arthroscopy vs. MRI for a detailed assessment of cartilage disease in osteoarthritis: diagnostic value of MRI in clinical practice
<p>Abstract</p> <p>Background</p> <p>In patients with osteoarthritis, a detailed assessment of degenerative cartilage disease is important to recommend adequate treatment. Using a representative sample of patients, this study investigated whether MRI is reliable for a detailed cartilage assessment in patients with osteoarthritis of the knee.</p> <p>Methods</p> <p>In a cross sectional-study as a part of a retrospective case-control study, 36 patients (mean age 53.1 years) with clinically relevant osteoarthritis received standardized MRI (sag. T1-TSE, cor. STIR-TSE, trans. fat-suppressed PD-TSE, sag. fat-suppressed PD-TSE, Siemens Magnetom Avanto syngo MR B 15) on a 1.5 Tesla unit. Within a maximum of three months later, arthroscopic grading of the articular surfaces was performed. MRI grading by two blinded observers was compared to arthroscopic findings. Diagnostic values as well as intra- and inter-observer values were assessed.</p> <p>Results</p> <p>Inter-observer agreement between readers 1 and 2 was good (kappa = 0.65) within all compartments. Intra-observer agreement comparing MRI grading to arthroscopic grading showed moderate to good values for readers 1 and 2 (kappa = 0.50 and 0.62, respectively), the poorest being within the patellofemoral joint (kappa = 0.32 and 0.52). Sensitivities were relatively low at all grades, particularly for grade 3 cartilage lesions. A tendency to underestimate cartilage disorders on MR images was not noticed.</p> <p>Conclusions</p> <p>According to our results, the use of MRI for precise grading of the cartilage in osteoarthritis is limited. Even if the practical benefit of MRI in pretreatment diagnostics is unequivocal, a diagnostic arthroscopy is of outstanding value when a grading of the cartilage is crucial for a definitive decision regarding therapeutic options in patients with osteoarthritis.</p
Using the modified Delphi method to establish clinical consensus for the diagnosis and treatment of patients with rotator cuff pathology
- …