61 research outputs found

    Temperature Dependence of Facet Ridges in Crystal Surfaces

    Full text link
    The equilibrium crystal shape of a body-centered solid-on-solid (BCSOS) model on a honeycomb lattice is studied numerically. We focus on the facet ridge endpoints (FRE). These points are equivalent to one dimensional KPZ-type growth in the exactly soluble square lattice BCSOS model. In our more general context the transfer matrix is not stochastic at the FRE points, and a more complex structure develops. We observe ridge lines sticking into the rough phase where thesurface orientation jumps inside the rounded part of the crystal. Moreover, the rough-to-faceted edges become first-order with a jump in surface orientation, between the FRE point and Pokrovsky-Talapov (PT) type critical endpoints. The latter display anisotropic scaling with exponent z=3z=3 instead of familiar PT value z=2z=2.Comment: 12 pages, 19 figure

    Early detection of urothelial premalignant lesions using hexaminolevulinate fluorescence cystoscopy in high risk patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To evaluate fluorescence cystoscopy with hexaminolevulinate (HAL) in the early detection of dysplasia (DYS) and carcinoma in situ (CIS) in select high risk patients.</p> <p>Methods</p> <p>We selected 30 consecutive bladder cancer patients at high risk for progression. After endoscopic resection, all patients received (a) induction BCG schedule when needed, and (b) white light and fluorescence cystoscopy after 3 months. HAL at doses of 85 mg (GE Healthcare, Buckinghamshire, United Kingdom) dissolved in 50 ml of solvent to obtain an 8 mmol/L solution was instilled intravesically with a 12 Fr catheter into an empty bladder and left for 90 minutes. The solution was freshly prepared immediately before instillation. Cystoscopy was performed within 120 minutes of bladder emptying. Standard and fluorescence cystoscopy was performed using a double light system (Combilight PDD light source 5133, Wolf, Germany) which allowed an inspection under both white and blue light.</p> <p>Results</p> <p>The overall incidence was 43.3% dysplasia, 23.3% CIS, and 13.3% superficial transitional cell cancer. In 21 patients, HAL cystoscopy was positive with one or more fluorescent flat lesions. Of the positive cases, there were 4 CIS, 10 DYS, 2 association of CIS and DYS, 4 well-differentiated non-infiltrating bladder cancers, and 1 chronic cystitis. In 9 patients with negative HAL results, random biopsies showed 1 CIS and 1 DYS. HAL cystoscopy showed 90.1% sensitivity and 87.5% specificity with 95.2% positive predictive value and 77.8% negative predictive value.</p> <p>Conclusion</p> <p>Photodynamic diagnosis should be considered a very important tool in the diagnosis of potentially evolving flat lesions on the bladder mucosa such as DYS and CIS. Moreover, detection of dysplasic lesions that are considered precursors of CIS may play an important role in preventing disease progression. In our opinion, HAL cystoscopy should be recommended in the early follow-up of high risk patients.</p

    The Impact of Different Types of Assistive Devices on Gait Measures and Safety in Huntington's Disease

    Get PDF
    BACKGROUND: Gait and balance impairments lead to frequent falls and injuries in individuals with Huntington's disease (HD). Assistive devices (ADs) such as canes and walkers are often prescribed to prevent falls, but their efficacy is unknown. We systematically examined the effects of different types of ADs on quantitative gait measures during walking in a straight path and around obstacles. METHODS: Spatial and temporal gait parameters were measured in 21 subjects with HD as they walked across a GAITRite walkway under 7 conditions (i.e., using no AD and 6 commonly prescribed ADs: a cane, a weighted cane, a standard walker, and a 2, 3 or 4 wheeled walker). Subjects also were timed and observed for number of stumbles and falls while walking around two obstacles in a figure-of-eight pattern. RESULTS: Gait measure variability (i.e., coefficient of variation), an indicator of fall risk, was consistently better when using the 4WW compared to other ADs. Subjects also walked the fastest and had the fewest number of stumbles and falls when using the 4WW in the figure-of-eight course. Subjects walked significantly slower using ADs compared to no AD both across the GAITRite and in the figure-of-eight. Measures reflecting gait stability and safety improved with the 4WW but were made worse by some other ADs

    The effects of high frequency subthalamic stimulation on balance performance and fear of falling in patients with Parkinson's disease

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Balance impairment is one of the most distressing symptoms in Parkinson's disease (PD) even with pharmacological treatment (levodopa). A complementary treatment is high frequency stimulation in the subthalamic nucleus (STN). Whether STN stimulation improves postural control is under debate. The aim of this study was to explore the effects of STN stimulation alone on balance performance as assessed with clinical performance tests, subjective ratings of fear of falling and posturography.</p> <p>Methods</p> <p>Ten patients (median age 66, range 59–69 years) with bilateral STN stimulation for a minimum of one year, had their anti-PD medications withdrawn overnight. Assessments were done both with the STN stimulation turned OFF and ON (start randomized). In both test conditions, the following were assessed: motor symptoms (descriptive purposes), clinical performance tests, fear of falling ratings, and posturography with and without vibratory proprioceptive disturbance.</p> <p>Results</p> <p>STN stimulation alone significantly (p = 0.002) increased the scores of the Berg balance scale, and the median increase was 6 points. The results of all timed performance tests, except for sharpened Romberg, were significantly (p ≤ 0.016) improved. The patients rated their fear of falling as less severe, and the total score of the Falls-Efficacy Scale(S) increased (p = 0.002) in median with 54 points. All patients completed posturography when the STN stimulation was turned ON, but three patients were unable to do so when it was turned OFF. The seven patients with complete data showed no statistical significant difference (p values ≥ 0.109) in torque variance values when comparing the two test situations. This applied both during quiet stance and during the periods with vibratory stimulation, and it was irrespective of visual input and sway direction.</p> <p>Conclusion</p> <p>In this sample, STN stimulation alone significantly improved the results of the clinical performance tests that mimic activities in daily living. This improvement was further supported by the patients' ratings of fear of falling, which were less severe with the STN stimulation turned ON. Posturography could not be performed by three out of the ten patients when the stimulation was turned OFF. The posturography results of the seven patients with complete data showed no significant differences due to STN stimulation.</p

    CONSTRAINED REGISTRATION OF MULTIPLE RIGID OBJECTS IN CLOSE PROXIMITY: APPLICATION IN THE WRIST JOINT

    No full text
    Current diagnosis of wrist joint problems is hampered by poor understanding of wrist joint functioning. To gain insight into the relationship between function and anatomy we aim at building a statistical shape model of the wrist. As a basis for the statistical model we intend to use CT scans of different individuals that are mutually registered to a common pose. Unconstrained registration of individual bones does not lead to an anatomically feasible arrangement of the carpal bones. We propose to use a constrained 3D registration, where bone movements are based on bone geometry and joint kinematics. Constrained co-registration of wrists from different individuals in different postures demonstrates that our method finds anatomically feasible wrists in the same posture that are therefore a sound basis for a statistical shape model
    corecore