    Use of EPIC EMR for Early Identification and Management of Patients at Risk of Cardiac Implantable Electronic Device (CIED) Infection

    Get PDF
    Objectives Aim of our project was early identification of 100% of patients with a CIED IMPLANT presenting with bacteremia Process involves use of EPIC EMR to automatically identify patients with positive blood cultures Traditionally, cardiologists are alerted by the care team using the CONSULT system for management of these patients EPIC EMR as an adjunct to the CONSULT syste

    Lead-associated endocarditis: the important role of methicillin-resistant Staphylococcus aureus.

    Get PDF
    BACKGROUND: Infection is a potentially life-threatening complication of cardiac device implantation. Lead-associated endocarditis (LAE) may be the most serious complication since it is associated with a high mortality. METHODS: The medical records of patients referred to our institution for the treatment of LAE between 1999 and 2007 were reviewed. RESULTS: A total of 51 of 107 patients referred for device-related infections met the criteria for LAE. Of these, 19 occurred within 6 months of their most recent procedure (early), while the remaining 32 occurred more than 6 months later (mean = 31.9 months post procedure). Devices included pacemakers in 33 patients and ICDs in 18 patients. The most common organism responsible for infection was Staphylococcus aureus (S. aureus) followed by coagulase-negative staphylocci (22%) and streptococci (12%). Methicillin-resistant S. aureus (MRSA) accounted for 67% of the S. aureus infections. Coagulase-negative staphylococci were responsible for only 26% of early and 19% of late cases. A distant site of infection was common (26/51 = 51%), particularly in patients with MRSA LAE. The device and leads were removed percutaneously in all patients. Only one patient failed to respond to intravenous antibiotics. CONCLUSIONS: Our data suggest that methicillin-resistant S. aureus is an important pathogen in LAE. Since many infections occur months after the last device procedure, hematogenous spread of organisms from a distant site may be an important contributing factor. These data suggest that strategies to prevent hematogenous infection, particularly with S. aureus, are critical in patients with implantable cardiac devices

    Validation of a Novel, Non-Invasive System for Autonomic Profiling in Healthy Volunteers

    Get PDF
    Noninvasive profiling of the autonomic nervous system has been shown to have prognostic value in patients with myocardial infarction, CHF and diabetes. The ANSAR system (ANX 3.0, Philadelphia, PA) is a new commercially available system that utilizes respiratory rate, HR and BP to assess on-going sympathovagal modulation during various maneuvers known to evoke autonomic perturbations. Instead of using conventional Fast Fourier Transform for frequency domain analysis, a Continuous Wavelet Transform (CWT) is used to generate numerical and graphical data. The system calculates Low Frequency Area (LFA, analogous to LF Power) and Respiratory Frequency Area (RFA, analogous to High Frequency Power.) A time domain index (pNN50 is also calculated

    Trends in permanent pacemaker implantation in the United States from 1993 to 2009: increasing complexity of patients and procedures.

    Get PDF
    OBJECTIVES: This study sought to define contemporary trends in permanent pacemaker use by analyzing a large national database. BACKGROUND: The Medicare National Coverage Determination for permanent pacemaker, which emphasized single-chamber pacing, has not changed significantly since 1985. We sought to define contemporary trends in permanent pacemaker use by analyzing a large national database. METHODS: We queried the Nationwide Inpatient Sample to identify permanent pacemaker implants between 1993 and 2009 using the International Classification of Diseases-Ninth Revision-Clinical Modification procedure codes for dual-chamber (DDD), single-ventricular (VVI), single-atrial (AAI), or biventricular (BiV) devices. Annual permanent pacemaker implantation rates and patient demographics were analyzed. RESULTS: Between 1993 and 2009, 2.9 million patients received permanent pacemakers in the United States. Overall use increased by 55.6%. By 2009, DDD use increased from 62% to 82% (p \u3c 0.001), whereas single-chamber ventricular pacemaker use fell from 36% to 14% (p = 0.01). Use of DDD devices was higher in urban, nonteaching hospitals (79%) compared with urban teaching hospitals (76%) and rural hospitals (72%). Patients with private insurance (83%) more commonly received DDD devices than Medicaid (79%) or Medicare (75%) recipients (p \u3c 0.001). Patient age and Charlson comorbidity index increased over time. Hospital charges ($2011) increased 45.3%, driven by the increased cost of DDD devices. CONCLUSIONS: There is a steady growth in the use of permanent pacemakers in the United States. Although DDD device use is increasing, whereas single-chamber ventricular pacemaker use is decreasing. Patients are becoming older and have more medical comorbidities. These trends have important health care policy implications

    16-year trends in the infection burden for pacemakers and implantable cardioverter-defibrillators in the United States 1993 to 2008.

    Get PDF
    OBJECTIVES: We analyzed the infection burden associated with the implantation of cardiac implantable electrophysiological devices (CIEDs) in the United States for the years 1993 to 2008. BACKGROUND: Recent data suggest that the rate of infection following CIED implantation may be increasing. METHODS: The Nationwide Inpatient Sample (NIS) discharge records were queried between 1993 and 2008 using the 9th Revision of the International Classification of Diseases (ICD-9-CM). CIED infection was defined as either: 1) ICD-9 code for device-related infection (996.61) and any CIED procedure or removal code; or 2) CIED procedure code along with systemic infection. Patient health profile was evaluated by coding for renal failure, heart failure, respiratory failure, and diabetes mellitus. The infection burden and patient health profile were calculated for each year, and linear regression was used to test for changes over time. RESULTS: During the study period (1993 to 2008), the incidence of CIED infection was 1.61%. The annual rate of infections remained constant until 2004, when a marked increase was observed, which coincided with an increase in the incidence of major comorbidities. This was associated with a marked increase in mortality and in-hospital financial charges. CONCLUSIONS: The infection burden associated with CIED implantation is increasing over time and is associated with prolonged hospital stays and high financial costs

    Ampere Hour as a Predictor of Cardiac Resynchronization Defibrillator Pulse Generator Battery Longevity: A Multicenter Study

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/122444/1/pace12831_am.pdfhttp://deepblue.lib.umich.edu/bitstream/2027.42/122444/2/pace12831.pd

    Microwaves treat heart disease

    No full text
    IEEE Microwave Magazine, 8(1): pp. 70-75. DOI: http://dx.doi.org/10.1109/MMW.2007.28907

    Evaluation of Echogenic Material on Transvenous Leads by Transesophageal Echocardiography in Patients with and without Lead-associated Endocarditis

    Get PDF
    Echogenic material (EM) on non-infected leads in patients with cardiac implantable device is common on transesophageal echocardiography (TEE). Although several morphologic characteristics of EM are more commonly seen in transvenous lead-associated endocarditis, these characteristics alone are not diagnostic for lead-associated endocardiatis. Lead-associated EM on TEE should be interpreted within the overall clinical context