41 research outputs found
Physikalische Parameter extrakorporaler Stoßwellen
Prerequisites for the successful investigation of the mechanism of action of ESWT (extracorporeal shockwave therapy) and the establishment of treatment standards, are the ability to measure, and a knowledge of, the physical parameters involved. The most accurate measurements are obtained with laser hydrophones. Various parameters (amplitude, rise time, pulse width, pressure pulse decay, rarification phase) of a typical shock wave can thus be determined. These can then be used to calculate energy flux density, focal extent, focal volume and as well as focal energy, effective energy in a defined area, and effective biological energy. These parameters can be utilized to work out a theoretical treatment protocol
Toward the observation of interference effects in nonlinear Compton scattering
The photon spectrum from electrons scattering on multiple laser pulses
exhibits interference effects not present for scattering on a single pulse. We
investigate the conditions required for the experimental observation of these
interference effects in electron-laser collisions, in particular analysing the
roles of the detector resolution and the transverse divergence of the pump
electron beam.Comment: 8 pages, 5 figure
Fertigungsreife Entwicklung eines hochwaerme-, schalldaemmenden und waermespeichernden Ziegelwandsystems mit integriertem Waermespeicher (Kombi-Ziegel) Schlussbericht
With 22 tabs, 47 figs.SIGLECopy held by FIZ Karlsruhe; available from UB/TIB Hannover / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekDEGerman
Reduction of Bubble Cavitation by Modifying the Diffraction Wave from a Lithotripter Aperture
PURPOSE: A new method was devised to suppress the bubble cavitation in the lithotripter focal zone to reduce the propensity of shockwave-induced renal injury. MATERIALS AND METHODS: An edge extender was designed and fabricated to fit on the outside of the ellipsoidal reflector of an electrohydraulic lithotripter to disturb the generation of diffraction wave at the aperture, but with little effect on the acoustic field inside the reflector. RESULTS: Although the peak negative pressures at the lithotripter focus using the edge extender at 20 kV were similar to that of the original configuration (-11.1±0.9 vs −10.6±0.7 MPa), the duration of the tensile wave was shortened significantly (3.2±0.54 vs 5.83±0.56 μs, P<0.01). There is no difference, however, in both the amplitude and duration of the compressive shockwaves between these two configurations as well as the −6 dB beam width in the focal plane. The significant suppression effect of bubble cavitation was confirmed by the measured bubble collapse time using passive cavitation detection. At the lithotripter focus, while only about 30 shocks were needed to rupture a blood vessel phantom using the original HM-3 reflector at 20 kV, no damage could be produced after 300 shocks using the edge extender. Meanwhile, the original HM-3 lithotripter at 20 kV can achieve a stone comminution efficiency of 50.4±2.0% on plaster-of-Paris stone phantom after 200 shocks, which is comparable to that of using the edge extender (46.8±4.1%, P=0.005). CONCLUSIONS: Modifying the diffraction wave at the lithotripter aperture can suppress the shockwave-induced bubble cavitation with significant reduced damage potential on the vessel phantom but satisfactory stone comminution ability