35,149 research outputs found
Liquid storage tank venting device for zero gravity environment Patent
Venting device for liquid propellant storage tank using magnetic field to separate liquid and gaseous phase
Curved film cooling admission tube
Effective film cooling to protect a wall surface from a hot fluid which impinges on or flows along the surface is provided. A film of cooling fluid having increased area is provided by changing the direction of a stream of cooling fluid through an angle of from 135 deg. to 165 deg. before injecting it through the wall into the hot flowing gas. The 1, cooling fluid is injected from an orifice through a wall into a hot flowing gas at an angle to form a cooling fluid film. Cooling fluid is supplied to the orifice from a cooling fluid source via a turbulence control passageway having a curved portion between two straight portions. The angle through which the direction of the cooling fluid is turned results in less mixing of the cooling fluid with the hot gas, thereby substantially increasing the length of the film in a downstream direction
Automated microorganism Sample Collection Module
Modified Gelman Sampler obtains representative sample of microorganism population. Proposed Sample Collection Module is based on direct inoculation of selected solid growth media encased in a cartridge at all times except during inoculation. Cartridge can be handled with no danger of contamination to sample or operator
Rich nations, poor nations: how much can multiple equilibria explain?
This paper asks whether the income gap between rich and poor nations can be explained by multiple equilibria. We explore the quantitative implications of a simple two sector general equilibrium model that gives rise to multiplicity, and calibrate the model for a large number of countries. Under the assumptions of the model, around a quarter of the world’s economies are found to be in a low output equilibrium. The output gains associated with an equilibrium switch are sizeable, but well short of the vast income disparity observed in the data.poverty traps, multiple equilibria, TFP differences,calibration
Film-cooling effectiveness with developing coolant flow through straight and curved tubular passages
The data were obtained with an apparatus designed to determine the influence of tubular coolant passage curvature on film-cooling performance while simulating the developing flow entrance conditions more representative of cooled turbine blade. Data comparisons were made between straight and curved single tubular passages embedded in the wall and discharging at 30 deg angle in line with the tunnel flow. The results showed an influence of curvature on film-cooling effectiveness that was inversely proportional to the blowing rate. At the lowest blowing rate of 0.18, curvature increased the effectiveness of film cooling by 35 percent; but at a blowing rate of 0.76, the improvement was only 10 percent. In addition, the increase in film-cooling area coverage ranged from 100 percent down to 25 percent over the same blowing rates. A data trend reversal at a blowing rate of 1.5 showed the straight tubular passage's film-cooling effectiveness to be 20 percent greater than that of the curved passage with about 80 percent more area coverage. An analysis of turbulence intensity detain the mixing layer in terms of the position of the mixing interface relative to the wall supported the concept that passage curvature tends to reduce the diffusion of the coolant jet into the main stream at blowing rates below about. Explanations for the film-cooling performance of both test sections were made in terms differences in turbulences structure and in secondary flow patterns within the coolant jets as influenced by flow passage geometry
One-parameter extension of the Doi-Peliti formalism and relation with orthogonal polynomials
An extension of the Doi-Peliti formalism for stochastic chemical kinetics is
proposed. Using the extension, path-integral expressions consistent with
previous studies are obtained. In addition, the extended formalism is naturally
connected to orthogonal polynomials. We show that two different orthogonal
polynomials, i.e., Charlier polynomials and Hermite polynomials, can be used to
express the Doi-Peliti formalism explicitly.Comment: 10 page
Analysis for predicting adiabatic wall temperatures with single hole coolant injection into a low speed crossflow
Assuming the local adiabatic wall temperature equals the local total temperature in a low speed coolant mixing layer, integral conservation equations with and without the boundary layer effects are formulated for the mixing layer downstream of a single coolant injection hole oriented at a 30 degree angle to the crossflow. These equations are solved numerically to determine the center line local adiabatic wall temperature and the effective coolant coverage area. Comparison of the numerical results with an existing film cooling experiment indicates that the present analysis permits a simplified but reasonably accurate prediction of the centerline effectiveness and coolant coverage area downstream of a single hole crossflow streamwise injection at 30 degree inclination angle
Influence of coolant tube curvature on film cooling effectiveness as detected by infrared imagery
Thermal film cooling footprints observed by infrared imagery from straight, curved, and looped coolant tube geometries are compared. It was hypothesized that the differences in secondary flow and in the turbulence structure of flow through these three tubes should influence the mixing properties between the coolant and the main stream. A flow visualization tunnel, an infrared camera and detector, and a Hilsch tube were employed to test the hypothesis
Small gaps between products of two primes
Let denote the number that is a product of exactly two
distinct primes. We prove that
This sharpens an earlier result of the authors (arXivMath NT/0506067), which
had 26 in place of 6. More generally, we prove that if is any positive
integer, then
We also prove several other results on the representation of numbers with
exactly two prime factors by linear forms.Comment: 11N25 (primary) 11N36 (secondary
- …