8 research outputs found
Evaluation of Clear Sky Models for Satellite-Based Irradiance Estimates
This report describes an intercomparison of three popular broadband clear sky solar irradiance model results with measured data, as well as satellite-based model clear sky results compared to measured clear sky data. The authors conclude that one of the popular clear sky models (the Bird clear sky model developed by Richard Bird and Roland Hulstrom) could serve as a more accurate replacement for current satellite-model clear sky estimations. Additionally, the analysis of the model results with respect to model input parameters indicates that rather than climatological, annual, or monthly mean input data, higher-time-resolution input parameters improve the general clear sky model performance
Recommended from our members
Investigation of the Downwelling LW Differences Between the Niamey AMF Main and Supplementary Sites
The overall average downwelling longwave (LW) measured at the Niamey supplementary facility (S1) is 6-8 Wm-2 less than that measured by the two instruments located at the ARM Mobile Facility (AMF) main (N1) site. Examination of all other data available at both sites does not reveal any overarching differences that suggest this should be the case. However, examination of the pyrgeometer case and dome temperatures do suggest that the S1 values are also anomalously low, which in turn would explain the downwelling LW anomaly since the LW is calculated using these temperatures. Our recommendation then is to normalize the S1 data to the average N1 value by applying an adjustment factor to the S1 downwelling pyrgeometer case and dome temperatures (in Kelvin), then recalculating the downwelling LW values. The adjustment factor (0.00305) has been determined as that factor that brings the overall average S1 LWdn to agree with the overall average of the two N1 LWdn data series. We note that there is no reason to expect that the two site averages would actually be exactly equal to one another, and thus our recommendation is viewed as likely moving the S1 data in the right direction and by normalizing to the N1 average will help facilitate more meaningful temporal variability studies at least. It is also strongly recommended that for all future AMF deployments where supplementary sites will also be deployed, that the supplementary instrument systems (complete) be assembled as they will be operated in the field and run for at least a few days beside the corresponding AMF main site instruments, both at the beginning and end of the AMF field campaign. This is absolutely crucial so that all the measurements can be compared pre- and post-experiment to properly relate these measurements and systems, and to detect measurement anomalies such as those discussed in this report
Evaluation of Photodiode and Thermopile Pyranometers for Photovoltaic Applications
Accurately determining PV module performance in the field requires measurement of solar irradiance reaching the PV panel at a high level of accuracy and known uncertainty. Silicon detectors used in various solar energy measuring instruments including reference cells are potentially an attractive choice for multiple reasons that include faster responsivity than thermopile detectors, cheaper cost and lower maintenance. The main drawback though is the fact that the silicon detectors are only spectrally responsive in a narrow part of the solar spectrum. Therefore, to determine broadband solar irradiance a calibration factor that converts the narrowband response to broadband is required. Normally this calibration factor is a single number determined under standard conditions but then used for various scenarios including varying air-mass, panel orientation and atmospheric conditions. This would not have been an issue if all wavelengths that form the broadband spectrum responded uniformly to atmospheric constituents. Unfortunately the scattering and absorption signature varies widely across wavelengths and the calibration factor computed under certain test conditions is not appropriate for other conditions. This paper lays out the issues that will arise from the use of silicon detectors for PV performance measurement in the field. We also present a comparison of simultaneous spectral and broadband measurements from silicon and thermopile detectors and estimated measurement errors when using silicon devices for both array performance and resource assessment
Recommended from our members
Fiscal Year 2005 Solar Radiometry and Metrology Task Accomplishments
The National Renewable Energy Laboratory (NREL) Solar Radiometry and Metrology task provides traceable optical radiometric calibrations and measurements to photovoltaic (PV) researchers and the PV industry. Traceability of NREL solar radiometer calibrations to the World Radiometric Reference (WRR) was accomplished during Pyrheliometer Comparison at NREL in October 2004. Ten spectral and more than 200 broadband radiometers for solar measurements were calibrated this year. We measured detailed spectral distributions of the NREL and PV industry Pulsed Solar Simulators and are analyzing the influence of environmental variables on radiometer uncertainty. New systems for indoor and outdoor solar radiometer calibrations and ultraviolet (UV) spectral measurements and UV radiometer calibrations were purchased and tested. Optical metrology functions support the NREL Measurement and Characterization Task effort for ISO 17025 accreditation of NREL Solar Reference Cell Calibrations and have been integrated into the NREL quality system and audited for ISO17025 compliance
Recommended from our members
Improving Surface Radiation in a Satellite-Based Physical Model (Poster)
This poster provides an overview of the solar resource assessment work needed to achieve high penetrations of concentrating solar power or photovoltaics on the grid
Recommended from our members
Performance Testing using Silicon Devices - Analysis of Accuracy: Preprint
Accurately determining PV module performance in the field requires accurate measurements of solar irradiance reaching the PV panel (i.e., Plane-of-Array - POA Irradiance) with known measurement uncertainty. Pyranometers are commonly based on thermopile or silicon photodiode detectors. Silicon detectors, including PV reference cells, are an attractive choice for reasons that include faster time response (10 us) than thermopile detectors (1 s to 5 s), lower cost and maintenance. The main drawback of silicon detectors is their limited spectral response. Therefore, to determine broadband POA solar irradiance, a pyranometer calibration factor that converts the narrowband response to broadband is required. Normally this calibration factor is a single number determined under clear-sky conditions with respect to a broadband reference radiometer. The pyranometer is then used for various scenarios including varying airmass, panel orientation and atmospheric conditions. This would not be an issue if all irradiance wavelengths that form the broadband spectrum responded uniformly to atmospheric constituents. Unfortunately, the scattering and absorption signature varies widely with wavelength and the calibration factor for the silicon photodiode pyranometer is not appropriate for other conditions. This paper reviews the issues that will arise from the use of silicon detectors for PV performance measurement in the field based on measurements from a group of pyranometers mounted on a 1-axis solar tracker. Also we will present a comparison of simultaneous spectral and broadband measurements from silicon and thermopile detectors and estimated measurement errors when using silicon devices for both array performance and resource assessment
Recommended from our members
Advances in Solar Radiometry and Metrology
The Solar Radiometry and Metrology task at the National Renewable Energy Laboratory (NREL) provides traceable optical radiometric calibrations and measurements to photovoltaic (PV) researchers and the PV industry. Traceability of NREL solar radiometer calibrations to the World Radiometric Reference (WRR) was accomplished during the NREL Pyrheliometer Comparison in October 2003. The task has calibrated 10 spectral and more than 180 broadband radiometers for solar measurements. Other accomplishments include characterization of pyranometer thermal offset errors with laboratory and spectral modeling tools; developing a simple scheme to correct pyranometer data for known responsivity variations; and measuring detailed spectral distributions of the NREL High Intensity Pulsed Solar Simulator (HIPSS) as a function of lamp voltage and time. The optical metrology functions support the NREL Measurement and Characterization Task effort for ISO 17025 accreditation of NREL Solar Reference Cell Calibrations. Optical metrology functions have been integrated into the NREL quality system and audited for ISO17025 compliance