4 research outputs found

    Inter-fraction motion robustness and organ sparing potential of proton therapy for cervical cancer

    Get PDF
    Purpose: Large-field photon radiotherapy is current standard in the treatment of cervical cancer patients. However, with the increasing availability of Pencil Beam Scanning Proton Therapy (PBS-PT) and robust treatment planning techniques, protons may have significant advantages for cervical cancer patients in the reduction of toxicity. In this study, PBS-PT and photon Volumetric Modulated Arc Therapy (VMAT) were compared, examining target coverage and organ at risk (OAR) dose, taking inter- and intra-fraction motion into account. Materials and methods: Twelve cervical cancer patients were included in this in-silico planning study. In all cases, a planning CT scan, five weekly repeat CT scans (reCTs) and an additional reCT 10 min after the first reCT were available. Two-arc VMAT and robustly optimised two- and four-field (2F and 4F) PBS-PT plans were robustly evaluated on planCTs and reCTs using set-up and range uncertainty. Nominal OAR doses and voxel-wise minimum target coverage robustness were compared. Results: Average voxel-wise minimum accumulated doses for pelvic target structures over all patients were adequate for both photon and proton treatment techniques (D98 > 95%, [91.7–99.3%]). Average accumulated dose of the para-aortic region was lower than the required 95%, D98 > 94.4% [91.1–98.2%]. With PBS-PT 4F, dose to all OARs was significantly lower than with VMAT. Major differences were observed for mean bowel bag V15Gy: 60% [39–70%] for VMAT vs 30% [10–52%] and 32% [9–54%] for PBS-PT 2F and 4F and for mean bone marrow V10Gy: 88% [82–97%] for VMAT vs 66% [60–73%] and 67% [60–75%] for PBS-PT 2F and 4F. Conclusion: Robustly optimised PBS-PT for cervical cancer patients shows equivalent target robustness against inter- and intra-fraction variability compared to VMAT, and offers significantly better OAR sparing

    Differences in delineation guidelines for head and neck cancer result in inconsistent reported dose and corresponding NTCP

    Get PDF
    AbstractPurposeTo test the hypothesis that delineation of swallowing organs at risk (SWOARs) based on different guidelines results in differences in dose–volume parameters and subsequent normal tissue complication probability (NTCP) values for dysphagia-related endpoints.Materials and methodsNine different SWOARs were delineated according to five different delineation guidelines in 29 patients. Reference delineation was performed according to the guidelines and NTCP-models of Christianen et al. Concordance Index (CI), dosimetric consequences, as well as differences in the subsequent NTCPs were calculated.ResultsThe median CI of the different delineation guidelines with the reference guidelines was 0.54 for the pharyngeal constrictor muscles, 0.56 for the laryngeal structures and 0.07 for the cricopharyngeal muscle and esophageal inlet muscle. The average difference in mean dose to the SWOARs between the guidelines with the largest difference (maxΔD) was 3.5±3.2Gy. A mean ΔNTCP of 2.3±2.7% was found. For two patients, ΔNTCP exceeded 10%.ConclusionsThe majority of the patients showed little differences in NTCPs between the different delineation guidelines. However, large NTCP differences >10% were found in 7% of the patients. For correct use of NTCP models in individual patients, uniform delineation guidelines are of great importance

    Proton therapy of a pregnant patient with nasopharyngeal carcinoma

    Get PDF
    Background and purpose: Radiotherapy during pregnancy is rarely administered due to lack of data and practical challenges. This is the first detailed report of proton therapy as cancer treatment for a pregnant patient with nasopharyngeal carcinoma. Materials and methods: Pencil beam scanning proton therapy was prescribed to a pregnant patient to a total dose of 70 Gy (RBE) to the therapeutic CTV and 54.25 Gy to the prophylactic CTV, delivered in 35 fractions with a simultaneous integrated boost technique. Results: Phantom measurements showed a thirty-fold decrease in fetal radiation dose when using proton compared to photon therapy, with a total fetal dose of 5.5 mSv for the complete proton treatment, compared to 185 and 298 mSv for the photon treatment with and without lead shielding, respectively. After adminstering proton therapy during pregnancy, at 39 weeks of gestation, a healthy boy with a birthweight on the 83th percentile was delivered. Pediatric follow-up at 2 months of age of the offspring showed normal growth and age-adequate motor development with no signs of neurological problems. MR follow-up of the tumor 3 months after the end of treatment showed complete remission. Conclusion: This case demonstrates the potential of proton therapy for treatment during pregnancy. Compared to photon therapy, proton therapy can significantly limit fetal dose, while simultaneously offering a more optimized treatment to the patient

    Homogeneous broadening effect on temperature dependence of green upconversion luminescence in erbium doped fibers

    No full text
    <p>We study the green upconversion luminescence of Er3+ ions in an aluminosilicate optical fiber upon near infrared excitation at 787 nm. The dependence of the upconversion luminescence on temperature has been determined. As temperature drops from room to cryogenic temperatures, the upconversion green emission reaches a maximum around 40 K, and then decreases. A nearly quadratic dependence of the upconversion luminescence with excitation power is found, which is consistent with a sequential stepwise two-photon absorption process. These results have been explained with a semiclassical model that considers the inhomogeneous broadening of the optical transitions due to glass imperfections, and the dependence of the homogeneous linewidth broadening on temperature. (C) 2013 Elsevier B.V. All rights reserved.</p>
    corecore