290 research outputs found

    Effects of storage temperature and length of the storage period on hatchability and performance of red-legged partridge (Alectoris rufa) eggs

    Get PDF
    The aim of the present study was to investigate, in red-legged partridge (Alectoris rufa) eggs, the effects of 7- and 42-d storage periods with different storage temperatures (15, 12, and 9°C) on egg weight loss, hatchability, chick weight at hatch, incubation length, and development stage at embryonic mortality. A total of 420 red-legged partridge eggs were arranged in a 2 × 3 factorial design with 2 levels of storage length and 3 levels of storage temperature, resulting in 6 treatments consisting of 10 replications of 7 eggs each. We found that the storage length significantly reduced hatchability of the fertile eggs (P = 0.001), increasing late embryonic mortality (P = 0.001). Storage temperature did not influence on the embryonic mortality at any stage (P > 0.05). Egg weight loss during storage increased with the storage length (P 0.05). Nevertheless, incubation period decreased with the storage temperature for 7-d storage, and increased with the storage temperature for 42-d storage (P = 0.005). It can be concluded that in this study red-legged partridge eggs stored well with little deterioration up to 42 d at 9 and 12°C and 80% RH, in contrast to the lesser durability of eggs described in the literature for other poultry species. In case of 7-d storage periods, hatchability of A. rufa fertile eggs is higher when they are stored at 15°C. These findings are useful to address specific demands of game farms that require fertile eggs for hatching whose shelf-life should be long enough to maintain hatchability until further incubation. And, due to the marked reproductive seasonality of red-legged partridge, long-term storage of hatching eggs could permit the distribution of batches of chicks throughout the year.Junta de Andalucía AGR-23

    Seasonal and interannual changes in Ca and Mg of dripping waters in Kaite Cave (Spain)

    Get PDF
    Depto. de Geodinámica, Estratigrafía y PaleontologíaFac. de Ciencias GeológicasTRUEpu

    Implantación de un visor GIS con software libre en la Comunidad de Regantes del Trasvase Tajo-Segura de Totana, Murcia

    Get PDF
    En el ámbito del desarrollo de software orientado a la implementación de sistemas de información geográfica, una de las empresas de referencia a nivel internacional es la multinacional estadounidense Esri. En particular, en el contexto de los visores cartográficos para la web, por la experiencia del usuario que aportan. No obstante, la utilización de visores, tal y como los ofrece Esri en su sitio web, queda circunscrita al consumo de servicios ArcGIS Server, que sólo se pueden gestionar mediante la aplicación de Esri ArcGIS for Server. El elevado coste de la adquisición de este software propicia, en muchos casos, la búsqueda de soluciones alternativas, que casi siempre pasan por la utilización de librerías de desarrollo de código abierto, como son OpenLayers, GeoExt y ExtJS, entre otras. En este trabajo se plantea una propuesta que aprovecha las características funcionales del visor de Esri, evitando recurrir a ArcGIS for Server como servidor de mapas. Esto es posible gracias a la generación de servicios WMS y WFS a partir de software libre (servidores de mapas MapServer o GeoServer) y, al hecho de que Esri mantenga liberado bajo la licencia Apache 2.0 el código de su visor, permitiendo la alteración del código, lo que permite implementar capacidades funcionales nuevas, como la recuperación interactiva de datos temáticos (operación GetFeatureInfo en servicios WMS) y las búsquedas multicriterio sobre el mapa (operación GetFeature en servicios WFS). Este visor de La Compañía® ha sido implantado con éxito en la Comunidad de Regantes del Trasvase Tajo-Segura de Totana en Murcia, poniendo de manifiesto de que con software libre es posible construir visores con las mismas y/o mejores funcionalidades que los visores implementados con software propietario, y reforzar las ventajas en el ahorro de costes aplicando software libre, logrando con ello independencia tecnológica de las empresas que comercializan software propietario

    Catálogo (Glosario) de voces y términos de relaciones internacionales y comercio internacional: Herramienta práctica para estudiante de estas disciplinas

    Get PDF
    Se pretende crear un Catálogo de voces de Relaciones Internacionales y Comercio Internacional sobre los principales temas que componen la agenda internacional del siglo XXI, reforzando el aprendizaje teórico-practico de ambas titulaciones

    Chondroid Tumors: Review of Salient Imaging Features and Update on the WHO Classification

    Full text link
    Chondrogenic tumors are typically well recognized on radiographs, but differentiation between benign and malignant cartilaginous lesions can be difficult both for the radiologist and for the pathologist. Diagnosis is based on a combination of clinical, radiological and histological findings. While treatment of benign lesions does not require surgery, the only curative treatment for chondrosarcoma is resection. This article (1) emphasizes the update of the WHO classification and its diagnostic and clinical effects; (2) describes the imaging features of the various types of cartilaginous tumors, highlighting findings that can help differentiate benign from malignant lesions; (3) presents differential diagnoses; and (4) provides pathologic correlation. We attempt to offer valuable clues in the approach to this vast entit

    New Nuclear Medicine techniques in hyperparathyroidism surgery

    Get PDF
    [EN]Introduction and objective:Radioguided surgery of hyperparathyroidism (HPT) has substantially evolved in recent years, due to the development of new intraoperative tools and the improvement of pre-operative techniques. The aim of this work is to perform a review of the role of choline PET-CT as a preoperative technique, as well as of the use of intraoperative tools, in the radioguided localization of parathyroid adenomas.Synthesis:Choline PET-CT is a pre-operative technique, alternative to the 99mTc-MIBI scintigraphy, for the pre-operative localization of HPT in cases where convencional techniques give negative or doubtful results. This technique has showed good results in two recently published meta-analysis. The radioguided localization by means of gamma probe is still the intraoperative technique of choice in cases where parathyroid glands show significant 99mTc-MIBI uptake. Hand-held gammacamera is an adjuvant tool to the probe, which allows performing an intraoperative imagine and ensuring the complete resection of the specimens. Free hand SPECT is already applied in parathyroid radioguided surgery, but its use is still not widespread, probably because the superiority of this technique over the probe and hand-held gammacamera has not been demonstrated. Radioguided occult lesion localization (ROLL) by means of 99mTc-MAA injection and 125I seed implantation are two successfully used alternatives for the radioguided localization of negative99mTc –MIBI parathyroid glands. Hybrid tracers are being used in the radioguided surgery of the sentinel node, but have not been applied yet in hyperparathyroidism. Conclusions: Choline PET-CT is an increasingly used tool in preoperative HPT localization. Although gammadetector probe remains of choice in HPT surgery —both for its good results at low cost and for the great accumulated experience—; the combined use of the hand-held gammaprobe could be helpful for particular cases as well as to ensure the total excision of the specimens. On the other hand, the injection of 125I seeds and 99mTc-MAA, guided by means of sonography, are useful in 99mTc- MIBI negative cases. Lastly, more experience is required on the application of free hand SPECT and hybrid tracers to HPT surgery on order to demonstrate their possible advantages compared to other widespread tools.[ES]Introducción y objetivo:/nLa cirugía radioguiada del hiperparatiroidismo (HPT) ha evolucionado en los últimos años, gracias a la aparición de nuevas herramientas intraoperatorias y al perfeccionamiento de las técnicas pre-operatorias. El objetivo de este trabajo es realizar una revisión actualizada del papel del PET-CT con colina como técnica preoperatoria, así como de las herramientas intraoperatorias, en la radiolocalización de adenomas de paratiroides. Síntesis: El PET-CT con colina es una técnica preoperatoria, alternativa a la gammagrafía con 99mTc-MIBI, para la localización pre-quirúrgica del HPT, en casos en que las pruebas convencionales sean negativas o dudosas. Esta técnica ha demostrado buenos resultados en dos metaanálisis publicados recientemente. La localización radioguiada mediante sonda gamma continúa siendo la técnica intraoperatoria de elección en los casos con glándulas paratiroides que muestran captación significativa de 99mTc-MIBI. La gammacámara portátil es una herramienta adyuvante a la sonda, que permite realizar una imagen intraoperatoria y asegurar la completa resección de los especímenes. El "free hand SPECT" ya se está aplicando en la cirugía radioguiada de paratiroides, pero aún su uso no está extendido, probablemente debido a que no se ha demostrado la superioridad de esta técnica frente al uso de la sonda y la gammacámara portátil. La radiolocalización de lesiones ocultas (ROLL) mediante inyección de 99mTc-MAA y la inyección de semillas de 125I son dos alternativas para la localización radioguiada de paratiroides 99mTc-MIBI negativas, y ya están siendo empleadas con éxito. Los trazadores híbridos, empleados ya en la cirugía radioguiada del ganglio centinela, aún no se han aplicado en el hiperparatiroidismo. Conclusiones: El PET-CT con colina es una herramienta exitosa y cada vez más utilizada en la localización pre-operatoria del HPT. Aunque la sonda gammadetectora sigue siendo de elección en la cirugía del HPT, tanto por sus buenos resultados, como por la gran experiencia acumulada y bajo coste; la adición de la gammacámara portátil podría ser de ayuda en casos concretos y para asegurar la exéresis completa de los especímenes. La inyección de semillas con 125I y de 99mTc-MAA, guiada por ecografía, es de utilidad en casos 99mTc-MIBI negativos. La "free hand SPECT" y los trazadores híbridos aún requieren más experiencia en su aplicación a la cirugía del HPT para demostrar sus posibles ventajas frente al resto de herramientas utilizadas
    corecore