6 research outputs found

    Total Luminal Volume Predicts Risk after Endovascular Aneurysm Repair

    Get PDF
    Objective: Large aneurysm diameter represents a well known predictor of late complications after endovascular aneurysm repair (EVAR). However, the role of the thrombus free lumen inside the abdominal aortic aneurysm (AAA) sac is not clear. It was hypothesised that greater luminal volume represents a relevant risk factor for late complications after EVAR. Methods: A retrospective cohort analysis was performed including all patients undergoing EVAR from 2005 to 2016 at a tertiary referral institution. Pre-operative AAA lumen volume was measured in centre lumen line reconstructions and patients were stratified into quartiles according to luminal volume. The primary endpoint was freedom from AAA related complications. Secondary endpoints were freedom from neck events (type 1A endoleak, migration >5 mm or any pre-emptive neck related intervention), iliac related events (type 1B endoleak or pre-emptive iliac related intervention), and overall survival. Results: Four hundred and four patients were included: 101 in the first quartile (Q1; <61 cm3). Patients with higher luminal volumes had wider, shorter, and more angulated proximal necks. There were more ruptured AAAs, more aorto-uni-iliac implanted devices and patients outside neck instructions for use in the 4th quartile. Five year freedo

    Device-specific outcomes after endovascular abdominal aortic aneurysm repair

    No full text
    Over the last decade, endovascular aneurysm repair (EVAR) has been used extensively for the elective treatment of infra-renal abdominal aneurysms. However, it remains unclear how specific devices perform and how they compare to others. We provide an overview of currently used endografts, and discuss the current evidence regarding device-specific outcomes. Published literature confirms differences in results according to endograft selection. These differences were more pronounced with older generations of devices, in comparison to newer models. Contemporary results are generally good and one should remember that no randomized data exist regarding individual device performance. Moreover, by the time there is enough follow-up to draw conclusions, the data is relatively obsolete due to constant improvements in endograft technology and design. Results from EVAR have been steadily improving and individualized device selection has shown to be valuable. It appears that patients with favorable anatomy do well with most modern endografts. Those with challenging anatomies may benefit more from a particular design, delivery and deployment feature requiring greater knowledge and experience for adequate device selection

    Calcification of the abdominal aorta as an independent predictor of cardiovascular events: A meta-analysis

    No full text
    Context: Abdominal aortic calcification (AAC) is a common finding in patients with atherosclerosis. Objective: The aim of this study was to demonstrate the incremental value of AAC in predicting long term cardiovascular (CV) outcome by conducting a meta-analysis of observational studies. Data sources: MEDLINE and Cochrane databases. Study selection Longitudinal studies with at least 2 years of follow-up, reporting the influence of AAC on CV outcome of general population patients. Data extraction: Four separate end points - coronary events, cerebrovascular events, all CV events and CV related death - were tested for their relationship with AAC at baseline, using weighted random effects meta-analysis. Heterogeneity was calculated using Q and I 2statistic tests. Publication bias was assessed by funnel plot symmetry and trim and fill methods. The importance of calcium quantification was also explored (sensitivity analysis). Results: 10 studies were included. An increased relative risk (RR) was found for all end points: for coronary events (five studies, n=11250) 1.81 (95% CI 1.54 to 2.14); for cerebrovascular events (four studies, n=9736) 1.37 (1.22 to 3.54); for all CV events (four studies, n=4960) 1.64 (1.24 to 2.17); and for CV death (three studies, n=4986) 1.72 (1.03 to 2.86). Analysis of studies presenting results in categories (no/minimal, moderate and severe calcification) revealed a stepwise increase in the RR for all end points. Significant heterogeneity was found in the included studies. Sources of heterogeneity were identified in the publication date, duration of follow-up, and mean age and gender differences in the included patient cohorts. Conclusion: Existing data suggest that AAC is a strong predictor of CV related events or death in the general population. The predictive impact is greater in more calcified aortas. The generalisability of the meta-anal

    Results of endovascular repair of infrarenal aortic aneurysms using the Endurant stent graft

    No full text
    Objective Recent reports showed that the Endurant stent graft (Medtronic Cardiovascular, Santa Rosa, Calif) is safe and effective for endovascular repair of abdominal aortic aneurysms (AAAs). However, due to its relatively recent introduction, only short-term follow-up data are available. This study presents the 4-year results using this device. Methods All clinical data, including detailed anatomic information of the first 100 consecutive patients treated with the Endurant stent graft for an infrarenal AAA in three Dutch high-volume hospitals, were prospectively collected. Computed tomography angiography was routinely performed before the procedure, ≤1 month, and at 1 year post-endovascular aneurysm repair. Thereafter, the imaging modality during yearly follow-up was individualized (duplex ultrasound imaging or computed tomography angiography). Patients were classified as within or outside the instructions for use (IFU) for analysis. Study end points were primary clinical success, overall and AAA-related mortality, and sac morphology changes and endoleak during follow-up. Estimates were obtained using Kaplan-Meier plots. Results The study included 100 consecutive patients (88 men) with a median age of 74 years (interquartile range [IQR], 67-79 years) and median AAA diameter of 58 mm (IQR, 55-65 mm), between December 2007 and March 2009. Twenty patients (20%) were treated outside the IFU (18, outside proximal neck IFU, one outside iliac IFU, and one outside both IFUs). Median follow-up was 48 months (IQR, 36-53 months), and no patients were lost. One contained rupture was observed after 1.5 months due to graft infection. No patients had graft migration. Two type Ia endoleaks, 5 type Ib endoleaks, and 15 type II endoleaks were found. Primary clinical success was 97%, 90%, 84% and 77% at 1, 2, 3, and 4 years, respectively. Primary clinical success was comparable for patients treated within or outside IFU (P =.20), although both patients outside iliac IFU needed a secondary iliac intervention. Over time, maximum aneurysm diameter decreased ≥5 mm, remained stable, and increased ≥5 mm in 58%, 32%, and 10% of the patients, respectively. All-cause mortality was 20% at 4 years, with a 3% AAA-related mortality. Conclusions The 4-year follow-up data of the Endurant stent graft for AAA treatment shows its use results in a low AAA-related mortality with adequate prevention of rupture or aneurysm growth. Although patients with very challenging anatomy were treated in our series, primary clinical success rates were comparable for patients treated within and outside the IFU. However, both patients outside the iliac IFU needed a secondary iliac intervention. The knowledge of the present results may aid in improving outcomes in the future. Copyrigh

    Adequate seal and no endoleak on the first postoperative computed tomography angiography as criteria for no additional imaging up to 5 years after endovascular aneurysm repair

    Get PDF
    Objective: Intensive image surveillance after endovascular aneurysm repair is generally recommended due to continued risk of complications. However, patients at lower risk may not benefit from this strategy. We evaluated the predictive value of the first postoperative computed tomography angiography (CTA) characteristics for aneurysm-related adverse events as a means of patient selection for risk-adapted surveillance. Methods: All patients treated with the Low-Permeability Excluder Endoprosthesis (W. L. Gore and Assoc, Flagstaff, Ariz) at a tertiary institution from 2004 to 2011 were included. First postoperative CTAs were analyzed for the presence of endoleaks, endograft kinking, distance from the lowermost renal artery to the start of the endograft, and for proximal and distal sealing length using center lumen line reconstructions. The primary end point was freedom from aneurysm-related
    corecore