8 research outputs found

    The influence of power properties of the wind turbine on energetic and economic indicators of electric energy production

    No full text
    In the article the influence of the parameters describing the characteristics of the wind power station on the performance and economical factors of production of electrical energy was shown. The parameters describing the characteristics of the wind turbine were as follows: the nominal power, the speed of gaining the nominal power and the speed of the starting up of the power station. The degree of the usage of the nominal power of the power station was taken as the performance factor. The net cash flow and discount payback time were assumed as the economical factors

    Effect of the biological activity of carbon filter beds on organic matter removal from water

    No full text
    Omówiono wyniki badań przeprowadzonych w skali technicznej w stacji oczyszczania wody w Gruszczynie, zaopatrującej w wodę Poznań i Swarzędz. Oczyszczana woda podziemna charakteryzowała się podwyższoną zawartością związków żelaza i manganu oraz substancji organicznych (OWO, barwa, utlenialność, absorbancja w nadfiolecie). Technologia oczyszczania wody obejmuje procesy napowietrzania otwartego, filtrację Io (złoża antracytowo-piaskowe), filtrację IIo (złoża granulowanego węgla aktywnego) oraz dezynfekcję. Badaniom poddano próbki węgla z różnych głębokości filtrów sorpcyjnych oraz wodę dopływającą i odpływającą z tych filtrów. W próbkach złoża węglowego oznaczono aktywność mikrobiologiczną metodą testu aktywności esteraz (EA) z dwuoctanem fluoresceiny (test FDA). W próbkach wody dopływającej i odpływającej z filtru sorpcyjnego oznaczono tlen rozpuszczony, wolny dwutlenek węgla, pH, zasadowość ogólną, OWO, utlenialność, absorbancję w nadfiolecie ( =254 nm) oraz ogólną liczbę bakterii w temperaturze 22 oC. Badania wykazały, że wszystkie pracujące w stacji oczyszczania wody złoża węgla aktywnego w filtrach sorpcyjnych były biologicznie aktywne. Stwierdzono, że aktywność mikrobiologiczna złóż węglowych była uzależniona od czasu pracy filtru po płukaniu złoża. Płukanie złóż filtrów sorpcyjnych powodowało przejściowe zmniejszenie aktywności biologicznej węgla aktywnego, która następnie zwiększała się wraz z upływem czasu trwania cyklu filtracyjnego Skuteczność usuwania substancji organicznych z wody w złożach filtrów węglowych nie przekraczała 40%, co prawdopodobnie miało związek z brakiem procesu utleniania (ozonowania) przed filtrami z węglem aktywnym.A full-scale study was conducted at the Water Treatment Plant of Gruszczyn, which supplies water to the municipalities of Poznan and Swarzedz. The groundwater treated there is characterized by elevated concentrations of manganese, iron and organic compounds (TOC, permanganate COD, color, UV absorbance). The water treatment train applied includes: open aeration, filtration Io (anthracite-sand bed), filtration IIo (granular active carbon bed; GAC bed) and disinfection. GAC samples collected at various depths of the adsorption columns, as well as samples of the influent to, and the effluent from, the adsorption columns were made subject to analysis. GAC samples were analyzed for esterase activity (EA) using the fluorescein diacetate (FDA) test. The samples of influent and effluent water were analyzed for dissolved oxygen, free carbon dioxide, pH, total alkalinity, TOC, permanganate COD, UV absorbance (?=254 nm) and total number of bacteria at 22 oC. The study has revealed that all the GAC beds in the adsorption columns operated by the Gruszczyn Water Treatment Plant were biologically active. The biological activity of the GAC beds was found to depend on the duration of the filter cycle after backwash. Backwash produced a periodic reduction in the biological activity of the GAC beds, which was followed by a gradual increase with the duration of the filter cycle. The efficiency of organic matter removal from the water in the GAC beds failed to exceed 40%, which seems to be attributable to the fact that the treatment train applied does not include ozonation as a prior step to filtration IIo which involves GAC beds

    Accelerating the Process of Filter Bed Adaptation to the Removal of Manganese: A Case Study

    No full text
    Omówiono wyniki badań przeprowadzonych w zakładzie oczyszczania wody "Mosina", największego obiektu poznańskiego systemu wodociągowego, będącego w trakcie modernizacji i rozbudowy do docelowej zdolności produkcyjnej 150 tys. m3/d. Ujmowana woda, pochodząca z kilku źródeł zasilania, ma podwyższoną zawartość związków żelaza (2÷4 gFe/m3) i manganu (0,5 gMn/m3). W 2004 r. zakończono I etap prac modernizacyjnych, który obejmował gruntowny remont filtrów pospiesznych. Dotychczasowe złoża piaskowe zastąpiono złożami dwuwarstwowymi antracytowo-piaskowymi, co w istotny sposób zwiększyło pojemność złóż na zanieczyszczenia. Cechą charakterystyczną złóż filtracyjnych jest ich znaczna wysokość (1,7 m). W pracy przedstawiono doświadczenia eksploatacyjne, które pozwoliły na skrócenie teoretycznego 3÷4 miesięcznego okresu wpracowania nowych złóż do 3÷4 tygodni. Wykorzystywano szereg rozwiązań technologicznych, które umożliwiły uzyskanie szybkiego efektu odmanganiania wody, przy czym w okresie rozruchu filtrów woda zawierała jeszcze ponadnormatywną zawartość związków manganu. W pracy podano zastosowane w praktyce sposoby uaktywniania złóż filtracyjnych, czas ich wpracowania oraz omówiono wpływ cykli filtracyjnych na stabilność pracy układu filtracji pospiesznej.The study was carried out in the Water Treatment Plant Mosina, the largest object of the water distribution system for the city of Poznań. The plant is now being modernized and developed to achieve the capacity of 150,000 m3/d. The water to be treated comes from several sources and shows elevated concentrations of iron and manganese compounds (2-4 gFe/m3 and 0.5 gMn/m3, respectively). The first stage of the modernization process included the major repair of rapid filters and was completed in 2004. The existing sand filters were replaced with double-layer, anthracite-sand filters (of 1.7 m depth), which increased considerably the overall capacity of the filter beds to retain pollutants. With the dual media filters it was possible to reduce the theoretical 3-4 months' period of adaptation to 3-4 weeks. The implementation of a number of advanced technological concepts enabled a quick and efficient manganese removal, though at the initial stage of filter operation, the effluent concentrations of manganese compounds exceeded the set standards. The paper gives an account of the methods used for the activation of the modernized beds and the period of their adaptation, as well as describes the effect of the filter cycles on the stability of the rapid filtration system

    Experience with the implementation of chlorine dioxide for water disinfection in Mosina Water Treatment Plant

    No full text
    W pracy omówiono doświadczenia wynikające z wprowadzania dwutlenku chloru do dezynfekcji wody oczyszczonej na stacji "Mosina", zaopatrującej aglomerację poznańską w wodę wodociągową. Stwierdzono, że w chwili osiągnięcia jednakowego udziału dotychczas stosowanego chloru i nowo wprowadzonego dwutlenku chloru (50%/50%)) nastąpił niekontrolowany rozwój bakterii w wodzie, który został zahamowany dopiero w miarę wzrostu udziału chloru w mieszaninie dezynfektantów. Ponadto ustalono, że stosując oba środki dezynfekcyjne, zmienna powinna być dawka chloru, a dwutlenek chloru powinien być dawkowany w stałej ilości. Wykazano, że wprowadzenie nowego reagenta do wody zmieniło jej skład chemiczny, na skutek czego nastąpiły zaburzenia utrwalonej przez wiele lat równowagi w sieci wodociągowej. Ponowne doprowadzenie do stabilizacji wody w sieci było procesem długotrwałym. Rozległy system wodociągowy aglomeracji poznańskiej wymaga dobrego zabezpieczenia wody przed wtórnym zanieczyszczeniem oraz ciągłej kontroli jej jakości, przede wszystkim w zakresie analizy bakteriologicznej. Zastosowanie samego dwutlenku chloru do dezynfekcji wody w stacji wodociągowej "Mosina", bez zwiększenia skuteczności usuwania substancji organicznych, nie było możliwe.The paper gives an account of the experience gained while implementing chlorine dioxide for water disinfection at the Mosina Water Treatment Plant, which supplies tap water to the city of Poznan. It was found that when the proportion of the chlorine used so far to the chlorine dioxide being implemented was 50%/50%, this was paralleled by an uncontrolled bacterial growth in the water, which was inhibited by increasing the proportion of chlorine in the mixture of the two disinfectants. Another finding produced by the study was that when both the disinfectants were applied, it was possible to vary the chlorine dose while chlorine dioxide had to be dosed in the same amount. The addition of a new reagent brought about changes in the chemical composition of the water, thus disturbing the balance that had stabilized in the water-pipe network for many years. The process of restoring water stabilization in the pipeline was a long-term one. The large water supply system for the city of Poznan requires efficient actions to prevent water recontamination, as well as a reliable, continuous control of water quality primarily to ensure bacteriological safety. The application of chlorine dioxide alone to water disinfection at the Mosina Water Treatment Plant without increasing the efficiency of organic matter removal was found to be a failed attempt

    Evaluation of WIN-ESTIMATE 2.5 Maruyama computer program in estimation of lymph nodes metastases in gastric cancer patients

    No full text
    Celem pracy jest przedstawienie możliwości programu komputerowego WIN-ESTIMATE, stworzonego w 1984 r. przez Keichi Maruyamę – ordynatora oddziału chirurgii w Narodowym Szpitalu Onkologicznym w Tokio, a następnie zmodyfikowanego i przystosowanego do środowiska Windows przez zespół Rüdigera Siewerta z Kliniki Chirurgii Uniwersytetu Technicznego w Monachium. Program ten w obecnej wersji 2.5 szacuje przedoperacyjną obecność przerzutów w węzłach chłonnych u poszczególnych chorych poprzez porównanie ich danych z informacjami zawartymi w bazie danych pacjentów leczonych w latach 1969-1989. W analizie retrospektywnej sprawdzono zastosowanie programu Maruyamy w polskim ośrodku chirurgicznym. Badaniami objęto 40 chorych na raka żołądka, w tym 9 kobiet i 31 mężczyzn. Wszyscy pacjenci przebyli resekcję żołądka z limfadenektomią w ówczesnej II Katedrze i Klinice Chirurgii Ogólnej Akademii Medycznej w Lublinie, a całość danych klinicznych i patologicznych wprowadzano do programu i poddano analizie statystycznej z zastosowaniem nieparametrycznego testu Kruskala- Wallisa. Analiza wykazała, że program ten umożliwia niezależnie od przyjętych standardów dokładną i indywidualną ocenę rozległości zabiegu operacyjnego.The aim of the study is evaluation of possibilities of WINESTIMATE computer program application, created in 1984 by Keichi Maruyama, the head of the Surgery Department in National Cancer Center in Tokyo, and subsequently modified and Windows-adapted by Rüdiger Siewert’s team of the Surgery Department, Technical University of Munich. The upgraded 2.5 version of the program estimates preoperatively the presence of lymph nodes metastases in patients and compares data with records of patients who underwent surgical treatment between 1969 and 1989. Presented retrospective analysis shows how the application of Maruyama program complies with the situation of surgery centres in Poland. Forty gastric cancer patients (31 men and 9 women) were included in the study. All patients underwent stomach resection with lymphadenectomy in 2nd Department of General Surgery, Medical University of Lublin. The clinical and pathological data were introduced into the program. Kruskal and Wallis’ non-parametric test was used in the statistic analysis. Results evaluation proved that regardless of the adopted standards, computer program allows a thorough and individual estimation of the extent of the necessary surgical treatment