71 research outputs found
Towards Understanding Spontaneous Speech: Word Accuracy vs. Concept Accuracy
In this paper we describe an approach to automatic evaluation of both the
speech recognition and understanding capabilities of a spoken dialogue system
for train time table information. We use word accuracy for recognition and
concept accuracy for understanding performance judgement. Both measures are
calculated by comparing these modules' output with a correct reference answer.
We report evaluation results for a spontaneous speech corpus with about 10000
utterances. We observed a nearly linear relationship between word accuracy and
concept accuracy.Comment: 4 pages PS, Latex2e source importing 2 eps figures, uses icslp.cls,
caption.sty, psfig.sty; to appear in the Proceedings of the Fourth
International Conference on Spoken Language Processing (ICSLP 96
The Quantum Speed Limit of Optimal Controlled Phasegates for Trapped Neutral Atoms
We study controlled phasegates for ultracold atoms in an optical potential. A
shaped laser pulse drives transitions between the ground and electronically
excited states where the atoms are subject to a long-range 1/R^3 interaction.
We fully account for this interaction and use optimal control theory to
calculate the pulse shapes. This allows us to determine the minimum pulse
duration, respectively, gate time T that is required to obtain high fidelity.
We accurately analyze the speed limiting factors, and we find the gate time to
be limited either by the interaction strength in the excited state or by the
ground state vibrational motion in the trap. The latter needs to be resolved by
the pulses in order to fully restore the motional state of the atoms at the end
of the gate.Comment: 11 pages, 10 figures, 1 tabl
Robustness of high-fidelity Rydberg gates with single-site addressability
Controlled phase (CPHASE) gates can in principle be realized with trapped
neutral atoms by making use of the Rydberg blockade. Achieving the ultra-high
fidelities required for quantum computation with such Rydberg gates is however
compromised by experimental inaccuracies in pulse amplitudes and timings, as
well as by stray fields that cause fluctuations of the Rydberg levels. We
report here a comparative study of analytic and numerical pulse sequences for
the Rydberg CPHASE gate that specifically examines the robustness of the gate
fidelity with respect to such experimental perturbations. Analytical pulse
sequences of both simultaneous and stimulated Raman adiabatic passage (STIRAP)
are found to be at best moderately robust under these perturbations. In
contrast, optimal control theory is seen to allow generation of numerical
pulses that are inherently robust within a predefined tolerance window. The
resulting numerical pulse shapes display simple modulation patterns and their
spectra contain only one additional frequency beyond the basic resonant Rydberg
gate frequencies. Pulses of such low complexity should be experimentally
feasible, allowing gate fidelities of order 99.90 - 99.99% to be achievable
under realistic experimental conditions.Comment: 12 pages, 14 figure
Controlling the transport of an ion: Classical and quantum mechanical solutions
We investigate the performance of different control techniques for ion
transport in state-of-the-art segmented miniaturized ion traps. We employ
numerical optimization of classical trajectories and quantum wavepacket
propagation as well as analytical solutions derived from invariant based
inverse engineering and geometric optimal control. We find that accurate
shuttling can be performed with operation times below the trap oscillation
period. The maximum speed is limited by the maximum acceleration that can be
exerted on the ion. When using controls obtained from classical dynamics for
wavepacket propagation, wavepacket squeezing is the only quantum effect that
comes into play for a large range of trapping parameters. We show that this can
be corrected by a compensating force derived from invariant based inverse
engineering, without a significant increase in the operation time
Krotov: A Python implementation of Krotov's method for quantum optimal control
We present a new open-source Python package, krotov, implementing the quantum optimal control method of that name. It allows to determine time-dependent external fields for a wide range of quantum control problems, including state-to-state transfer, quantum gate implementation and optimization towards an arbitrary perfect entangler. Krotov's method compares to other gradient-based optimization methods such as gradient-ascent and guarantees monotonic convergence for approximately time-continuous control fields. The user-friendly interface allows for combination with other Python packages, and thus high-level customization
Optimizing for an arbitrary perfect entangler: I. Functionals
Optimal control theory is a powerful tool for improving figures of merit in
quantum information tasks. Finding the solution to any optimal control problem
via numerical optimization depends crucially on the choice of the optimization
functional. Here, we derive a functional that targets the full set of two-qubit
perfect entanglers, gates capable of creating a maximally-entangled state out
of some initial product state. The functional depends on easily-computable
local invariants and uniquely determines when a gate evolves into a perfect
entangler. Optimization with our functional is most useful if the two-qubit
dynamics allows for the implementation of more than one perfect entangler. We
discuss the reachable set of perfect entanglers for a generic Hamiltonian that
corresponds to several quantum information platforms of current interest
Quantum computing implementations with neutral particles
We review quantum information processing with cold neutral particles, that
is, atoms or polar molecules. First, we analyze the best suited degrees of
freedom of these particles for storing quantum information, and then we discuss
both single- and two-qubit gate implementations. We focus our discussion mainly
on collisional quantum gates, which are best suited for atom-chip-like devices,
as well as on gate proposals conceived for optical lattices. Additionally, we
analyze schemes both for cold atoms confined in optical cavities and hybrid
approaches to entanglement generation, and we show how optimal control theory
might be a powerful tool to enhance the speed up of the gate operations as well
as to achieve high fidelities required for fault tolerant quantum computation.Comment: 19 pages, 12 figures; From the issue entitled "Special Issue on
Neutral Particles
Primary staging and follow-up in melanoma patients – monocenter evaluation of methods, costs and patient survival
In a German cohort of 661 melanoma patients the performance, costs and survival benefits of staging methods (history and physical examination; chest X-ray; ultrasonography of the abdomen; high resolution sonography of the peripheral lymph nodes) were assessed at initial staging and during follow-up of stage I/II+III disease. At initial staging, 74% (23 out of 31) of synchronous metastases were first detected by physical examination followed by sonography of the lymph nodes revealing 16% (5 out of 31). Other imaging methods were less efficient (Chest X-ray: one out of 31; sonography of abdomen: two out of 31). Nearly 24% of all 127 first recurrences and 18% of 73 second recurrences developed in patients not participating in the follow-up programme. In follow-up patients detection of first or second recurrence were attributed to history and physical examination on a routine visit in 47 and 52% recurrences, respectively, and to routine imaging procedures in 21 and 17% of cases, respectively. Lymph node sonography was the most successful technical staging procedure indicating 13% of first relapses, but comprised 24% of total costs of follow-up in stage I/II. Routine imaging comprised nearly 50% of total costs for follow-up in stage I/II and in stage III. The mode of detecting a relapse (‘patient vs. doctor-diagnosed’ or ‘symptomatic vs asymptomatic’) did not significantly influence patients overall survival. Taken together, imaging procedures for routine follow-up in stage I/II and stage III melanoma patients were inefficient and not cost-efficient
- …