31 research outputs found

    Impact of Cardiac Computed Tomographic Angiography Findings on Planning of Cancer Therapy in Patients with Concomitant Structural Heart Disease

    Get PDF
    Background. Exclusion of underlying coronary artery disease (CAD) is essential in the diagnosis of chemotherapy-induced cardiomyopathy. Presence and severity of CAD can also impact the choice of therapy in cancer patients. The value of cardiac computed tomographic angiography (CCTA) in this setting has not been reported. Methods. We collected data on the clinical presentation and indications for CCTA performed from January to December 2008 at the University of Texas MD Anderson Cancer Center (MDACC). All examinations were performed using a 64-detector scanner. CCTA results and subsequent treatment decisions were examined. Results. A total of 80 patients underwent CCTA during the study period for the following indications (not mutually exclusive): cardiomyopathy of unknown etiology in 33 pts (41.3%), chest pain in 32 (40.0%), abnormal stress test in 16 (20.0%), abnormal cardiac markers in 8 (10.0%), suspected cardiac mass or thrombus in 7 (8.8%). Chemotherapy-induced cardiomyopathy was diagnosed in 18 pts (22.5%). Severe CAD was detected in 22 pts (27.5%); due to concomitant advanced cancer or patient refusal, only 12 underwent coronary angiogram. Of these, 4 pts (5% of total) underwent coronary artery bypass grafting. A total of 41 pts (51.3%) had their cancer management altered based on CCTA findings. Conclusion. CCTA is useful in evaluating cancer pts with structural heart disease and can have an impact on the management of cancer and cardiac disease

    Primary Thoracic Sarcomas

    No full text

    Implications for high-precision dose radiation therapy planning or limited surgical resection after percutaneous computed tomography-guided lung nodule biopsy using a tract sealant

    No full text
    Purpose: Precision radiation therapy such as stereotactic body radiation therapy and limited resection are being used more frequently to treat intrathoracic malignancies. Effective local control requires precise radiation target delineation or complete resection. Lung biopsy tracts (LBT) on computed tomography (CT) scans after the use of tract sealants can mimic malignant tract seeding (MTS) and it is unclear whether these LBTs should be included in the calculated tumor volume or resected. This study evaluates the incidence, appearance, evolution, and malignant seeding of LBTs. Methods and materials: A total of 406 lung biopsies were performed in oncology patients using a tract sealant over 19 months. Of these patients, 326 had follow-up CT scans and were included in the study group. Four thoracic radiologists retrospectively analyzed the imaging, and a pathologist examined 10 resected LBTs. Results: A total of 234 of 326 biopsies (72%, including primary lung cancer [n = 98]; metastases [n = 81]; benign [n = 50]; and nondiagnostic [n = 5]) showed an LBT on CT. LBTs were identified on imaging 0 to 3 months after biopsy. LBTs were typically straight or serpiginous with a thickness of 2 to 5 mm. Most LBTs were unchanged (92%) or decreased (6.3%) over time. An increase in LBT thickness/nodularity that was suspicious for MTS occurred in 4 of 234 biopsies (1.7%). MTS only occurred after biopsy of metastases from extrathoracic malignancies, and none occurred in patients with lung cancer. Conclusions: LBTs are common on CT after lung biopsy using a tract sealant. MTS is uncommon and only occurred in patients with extrathoracic malignancies. No MTS was found in patients with primary lung cancer. Accordingly, potential alteration in planned therapy should be considered only in patients with LBTs and extrathoracic malignancies being considered for stereotactic body radiation therapy or wedge resection
    corecore