90 research outputs found

    Measuring communication difficulty through effortful speech production during conversation

    Get PDF
    This study describes the use of a novel conversation elicitation framework to collect fluent, dynamic conversational speech in simulated realistic acoustic environments of varying complexities. Our aim is to quantify speech modifications during conversation, which characterize effortful speech, as a function of the difficulty of the acoustic environment. We report speech production data at the acoustic-phonetic level (vocal level, mid-frequency emphasis, formant frequencies and formant bandwidths), as well as at higher levels of analysis including utterance duration and turn overlap durations. The sensitivity and test-retest reliability of different speech production measures to changes in acoustic environment are reported. We propose a multi-dimensional view of effortful speech modifications. Considering speech modifications across different linguistic levels provides a richer view of the effects of the acoustic environment on communication as compared with consideration of low-level acoustic-phonetic markers alone. Finally, we describe how consideration of speech modification data may form the basis of a measure of communication effort with scope for the assessment of the impacts of hearing impairment and amplification upon ease of spoken communication

    A self-fitting hearing aid: need and concept

    No full text
    The need for reliable access to hearing health care services is growing globally, particularly in developing countries and in remotely located, underserved regions in many parts of the developed world. Individuals with hearing loss in these areas are at a significant disadvantage due to the scarcity of local hearing health care professionals and the high cost of hearing aids. Current approaches to making hearing rehabilitation services more readily available to underserved populations include teleaudiology and the provision of amplification devices outside of the traditional provider-client relationship. Both strategies require access to such resources as dedicated equipment and/or specially trained staff. Another possible strategy is a self-fitting hearing aid, a personal amplification device that is equipped with an onboard tone generator to enable user-controlled, automated, in situ audiometry; an onboard prescription to determine the initial hearing aid settings; and a trainable algorithm to enable user-controlled fine-tuning. The device is thus assembled, fitted, and managed by the user without the need for audiological or computer support. This article details the self-fitting concept and its potential application in both developing and developed countries. Potential advantages and disadvantages of such a device are discussed, and considerations for further investigations into the concept are presented. Overall, the concept is considered technologically viable with the main challenges anticipated to be development of clear, simple user instructions and a delivery model that ensures reliable supplies of instant-fit ear tips and batteries

    Real-life efficacy and reliability of training a hearing aid

    No full text
    Objectives: Commercial trainable hearing aids (HA) (i.e., devices that for a period are adjusted by the user in different acoustic environments and that subsequently with changing environments automatically adapt to the user’s preferred settings), are readily available; however, little information exists about the efficacy of training a HA. The purpose of this study was to investigate the efficacy and reliability of training a HA in everyday environments. Design: The participants were 26 hearing-impaired volunteers with a median age of 79 years and an average pure-tone average of 53 dB HL. Test devices were commercial, multimemory, prototype devices that enabled training of the compression characteristics in four frequency bands and in six sound classes. Participants wore the National Acoustic Laboratories nonlinear fitting procedure version 2 prescription for 3 weeks and trained the devices from the prescribed response for 3 weeks, before comparing their trained response with the prescription for 2 weeks. The devices were reset to the prescription, and 19 participants repeated the training and comparison trials. During the comparison trial, participants made daily diary ratings of their satisfaction with the programs, and a structured interview was completed at the end of the comparison trial. Results: The participants displayed different needs for changing the prescription, with more daily adjustments leading to training across more sound classes. Unreliable observations were obtained from 8 participants after each of the test and retest comparison trials. Of the 10 participants who made sufficient changes to the prescription during the first trial, 80% preferred their trained response. The 8 “low trainers” reported no preference, and also reported lower overall satisfaction with the device. Fewer adjustments were made during the repeat trial, resulting in less training. Significant correlations between trained variations were seen for 63% of 19 participants. Of the 10 participants who provided valid data after both comparison trials, those who trained the device consistently generally showed consistent preferences, and vice versa. Conclusions: For those who wanted a change to the prescription, training was mostly effective. Limited data on reliability showed reasonable consistency in training outcomes and preferences. Findings, in particular on reliability, should be verified in larger populations. A guideline on how to clinically manage training with clients is presented.11 page(s

    The Influence of Social Interaction and Physical Health on the Association Between Hearing and Depression With Age and Gender

    No full text
    Recent epidemiological data suggest the relation between hearing difficulty and depression is more evident in younger and middle-aged populations than in older adults. There are also suggestions that the relation may be more evident in specific subgroups; that is, other factors may influence a relationship between hearing and depression in different subgroups. Using cross-sectional data from the UK Biobank on 134,357 community-dwelling people and structural equation modelling, this study examined the potential mediating influence of social isolation and unemployment and the confounding influence of physical illness and cardiovascular conditions on the relation between a latent hearing variable and both a latent depressive episodes variable and a latent depressive symptoms variable. The models were stratified by age (40s, 50s, and 60s) and gender and further controlled for physical illness and professional support in associations involving social isolation and unemployment. The latent hearing variable was primarily defined by reported hearing difficulty in noise. For all subgroups, poor hearing was significantly related to both more depressive episodes and more depressive symptoms. In all models, the direct and generally small association exceeded the indirect associations via physical health and social interaction. Significant (depressive episodes) and near significant (depressive symptoms) higher direct associations were estimated for males in their 40s and 50s than for males in their 60s. There was at each age-group no significant difference in estimated associations across gender. Irrespective of the temporal order of variables, findings suggest that audiological services should facilitate psychosocial counselling

    Self-Fitting Hearing Aids

    No full text
    A self-contained, self-fitting hearing aid (SFHA) is a device that enables the user to perform both threshold measurements leading to a prescribed hearing aid setting and fine-tuning, without the need for audiological support or access to other equipment. The SFHA has been proposed as a potential solution to address unmet hearing health care in developing countries and remote locations in the developed world and is considered a means to lower cost and increase uptake of hearing aids in developed countries. This article reviews the status of the SFHA and the evidence for its feasibility and challenges and predicts where it is heading. Devices that can be considered partly or fully self-fitting without audiological support were identified in the direct-to-consumer market. None of these devices are considered self-contained as they require access to other hardware such as a proprietary interface, computer, smartphone, or tablet for manipulation. While there is evidence that self-administered fitting processes can provide valid and reliable results, their success relies on user-friendly device designs and interfaces and easy-to-interpret instructions. Until these issues have been sufficiently addressed, optional assistance with the self-fitting process and on-going use of SFHAs is recommended. Affordability and a sustainable delivery system remain additional challenges for the SFHA in developing countries. Future predictions include a growth in self-fitting products, with most future SFHAs consisting of earpieces that connect wirelessly with a smartphone and providers offering assistance through a telehealth infrastructure, and the integration of SFHAs into the traditional hearing health-care model
    • …
    corecore