22 research outputs found

    Comparison of experimentally measured and computational fluid dynamic predicted deposition and deposition uniformity of monodisperse solid particles in the Vitrocell® AMES 48 air-liquid-interface in-vitro exposure system

    Get PDF
    Accurately determining the delivered dose is critical to understanding biological response due to cell exposure to chemical constituents in aerosols. Deposition efficiency and uniformity of deposition was measured experimentally using monodisperse solid fluorescent particles with mass median aerodynamic diameters (MMAD) of 0.51, 1.1, 2.2 and 3.3 μm in the Vitrocell® AMES 48 air-liquid-interface (ALI) in vitro exposure system. Experimental results were compared with computational fluid dynamic, (CFD; using both Lagrangian and Eulerian approaches) predicted deposition efficiency and uniformity for a single row (N = 6) of petri dishes in the Vitrocell® AMES 48 system. The average experimentally measured deposition efficiency ranged from 0.007% to 0.43% for 0.51–3.3 μm MMAD particles, respectively. There was good agreement between average experimentally measured and the CFD predicted particle deposition efficiency, regardless of approach. Experimentally measured and CFD predicted average uniformity of deposition was greater than 45% of the mean for all particle diameters. During this work a new design was introduced by the manufacturer and evaluated using Lagragian CFD. Lagragian CFD predictions showed better uniformity of deposition, but reduced deposition efficiency with the new design. Deposition efficiency and variability in particle deposition across petri dishes for solid particles should be considered when designing exposure regimens using the Vitrocell® AMES 48 ALI in vitro exposure system

    The James Webb Space Telescope Mission

    Full text link
    Twenty-six years ago a small committee report, building on earlier studies, expounded a compelling and poetic vision for the future of astronomy, calling for an infrared-optimized space telescope with an aperture of at least 4m4m. With the support of their governments in the US, Europe, and Canada, 20,000 people realized that vision as the 6.5m6.5m James Webb Space Telescope. A generation of astronomers will celebrate their accomplishments for the life of the mission, potentially as long as 20 years, and beyond. This report and the scientific discoveries that follow are extended thank-you notes to the 20,000 team members. The telescope is working perfectly, with much better image quality than expected. In this and accompanying papers, we give a brief history, describe the observatory, outline its objectives and current observing program, and discuss the inventions and people who made it possible. We cite detailed reports on the design and the measured performance on orbit.Comment: Accepted by PASP for the special issue on The James Webb Space Telescope Overview, 29 pages, 4 figure

    Deposition efficiency and uniformity of monodisperse solid particle deposition in the Vitrocell (R) 24/48 Air-Liquid-Interface in vitro exposure system

    Get PDF
    A key to understanding biological response due to cell exposure to chemical constituents in aerosols is to accurately be able to determine the delivered dose. Deposition efficiency and uniformity of deposition was measured experimentally in the Vitrocell ® 24/48 air–liquid-interface (ALI) in vitro exposure system using monodisperse solid fluorescent particles with mass median aerodynamic diameters (MMAD) of 0.51, 1.1, 2.2 and 3.3 µm. Experimental results were compared with computational fluid dynamics (CFD; using both Lagrangian and Eulerian approaches) predicted deposition efficiency and uniformity for a single row (N = 6) of cell culture inserts in the Vitrocell ® 24/48 system. Deposited fluorescent monodisperse particles were quantified using fluorescent microscopy and Image J software. Experiments were conducted using a suspension of two particle MMADs with each experiment being conducted a total of three times on different days. The average experimentally measured deposition efficiency ranged from a low of 0.013% for 0.51 µm MMAD particles to a maximum 0.86% for 3.3 µm MMAD particles. There was good agreement between the average experimentally measured and the CFD predicted particle deposition efficiency (regardless of approach) with agreement being slightly better at the smaller MMADs. Experimentally measured and CFD predicted average uniformity of deposition was >45% of the mean and within 15% of the mean for 0.51 µm and 2.2 MMAD µm particles, respectively. Experimentally measured average uniformity of deposition was between 15 and 45% of the mean while CFD predictions were within 15% of the mean for 1.1 and 3.3 µm MMAD particles. The deposition efficiency and uniformity across the cell culture inserts for solid particles should be considered when designing exposure regimens using the Vitrocell ® 24/48 ALI in vitro exposure system

    Surveillance for early silicosis in high altitude miners using pulse oximetry.

    No full text
    Two cross-sectional studies in a high altitude region of Perú evaluated the role of pulse oximetry for detection of silicosis in high-altitude miners. In study one, exercise pulse oximetry and chest radiographs were used to evaluate 343 silica-exposed miners and 141 unexposed subjects for evidence of silicosis. Study 2 investigated the association between exercise oxygen saturation and silicosis in 32 non-silicotic and 65 silicotic miners. In study one, age (Odds Ratio [OR] 1.10, 95% Cofidence Interval (CI) 1.07-1.12) and resting oxygen saturation (OR 0.95, 95%CI 0.90-0.99) were associated with silicosis. In study two, years of mining employment (OR 1.14, 95%CI 1.05-1.23) and exercise oxygen saturation at 30% maximum heart rate (OR 0.86, 95%CI 0.75-0.99) were associated with silicosis. Hypoxemia at rest and with exercise is associated with silicosis in high altitude miners. Pulse oximetry should be further investigated as a screening tool for silicosis at high altitudes
    corecore